Method Article

Colorimetric Detection of a Bacterial Biomarker Using a Modified Litmus Test

July 8th, 2025

In This Article

Abstract

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Source: Tram, K., et al. Colorimetric Detection of Bacteria Using Litmus Test. J. Vis. Exp. (2016).

This video demonstrates a colorimetric E. coli detection method, involving an E. coli biomarker activating a DNAzyme, leading to cleavage of RNA linkage and detachment of a DNAzyme-urease conjugate. A subsequent colorimetric assay detects the E. coli biomarker through ammonia-induced pH changes.

Protocol

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

1. Preparing E. coli Cells for Testing

  1. For a desired cell suspension, transfer 1 ml of cultured stock to a 1.5 ml microfuge tube.
  2. Centrifuge the cells at 6,000 x g for 10 min at 4 °C. Carefully remove the supernatant without disturbing the cell pellet.
  3. Add 10 µl of reaction buffer to the cell pellet and resuspend the cells. Sonicate the cell suspension for 5 min. Transfer the cell suspension to an ice box for 5 min.
  4. Sonicate the cell suspension for another 5 min.
  5. Centrifuge the cell suspension at 13,000 x g for 10 min at 4 °C. Use the supernatant for testing (10 µl).

2. Litmus Test

  1. In a 1.5 ml microfuge tube, prewash the tube by adding and vortexing 100 µl of reaction buffer (RB) in the microfuge tube and discarding the buffer.
  2. Transfer 15 µl of assembled EC1 to the washed microfuge tube.
  3. Wash the magnetic beads by placing the microfuge tube on a magnetic rack. Remove the supernatant by pipetting. Remove the microfuge tube from the rack, add 100 µl of RB, and carefully resuspend the magnetic beads.
  4. Wash the MB two more times by repeating step 2.3.
  5. Place the microfuge tube back on the magnetic rack, remove the supernatant, and add the 10 µl E. coli sample prepared from step 1.3.
  6. Mix the sample and magnetic beads carefully by gently tapping on the microfuge tube.
  7. Incubate the reaction at room temperature for 1 hr.
  8. To the reaction, add 90 µl of ddH2O and place the microfuge tube onto a magnetic rack.
  9. After approximately 3 min of magnetic separation, carefully transfer 85 µl of the supernatant to a 0.5 ml microfuge tube. Withdraw the supernatant slowly to avoid collecting any magnetic beads.
  10. To the above microfuge tube add 15 µl of 0.04% phenol red and 100 µl of substrate solution.
  11. Take a photograph at specific time intervals to record color change.
    NOTE: The change in pH can also be monitored using a pH meter with a microelectrode. The starting pH should be approximately 5.2-5.5 (the solution is yellow). If not, the solution can be adjusted by the addition of 1 mM Acetate Buffer pH 5.0).

Access restricted. Please log in or start a trial to view this content.

Disclosures

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,
No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Ethylenediaminetetraacetic acid (EDTA)VWR AMRESCO105
Sodium Hydroxide (NaOH) pelletsBIO BASIC CANADA INCSB6789
Tris-baseVWR AMRESCO497
UreaVWR AMRESCOM123
Xylenecyanol FFSIGMA-ALDRICHX-4126
0.04% Phenol redSIGMA-ALDRICHP3532
10x T4 polynucleotide kinase reaction bufferLucigen30061-1
E. coli K12 (MG1655)ATCCATCC700926
Magnetic Bead (BioMag)Bangs Laboratories Inc
Magnetic Seperation RackNew England BioLabsS1506S
Microfuge tubesSarstedt72.69
Cell culture incubatorEppendorf ScientificM13520000
Branson Ultrasonic cleanerBransonN/A

Reprints and Permissions

Request permission to reuse the text or figures of this JoVE article

Request Permission

Tags

DNAzyme ActivationRNA CleavageUrease ConjugateMagnetic BeadsPhenol RedUrea HydrolysisAmmonia DetectionE coli Lysate

Related Articles