Source: Furman, J. L., et al. Sensitive Detection of Proteopathic Seeding Activity with FRET Flow Cytometry. J. Vis. Exp. (2015).

The video demonstrates a fluorescence resonance energy transfer (FRET) flow cytometry assay to detect the seeding activity of protein aggregates isolated from biological samples. Mammalian cells expressing tau reporter proteins are incubated with liposome transduction complexes containing tau seeds. These seeds mediate the aggregation of the reporter proteins, leading to generating a FRET positive signal in the flow cytometer.

Protocol

NOTE: This protocol emphasizes the use of FRET flow cytometry for detecting seeding activity from mouse biological samples. It is also compatible with recombinant fibrils and human biological samples. Mouse euthanasia and brain harvesting was performed in accordance with IACUC-approved procedures.

1. Brain Extraction

  1. Following deep anesthetization with isoflurane (2%), perfuse a mouse with ice-cold PBS containing 0.03% heparin, and extract the brain following the details described in Gage et al.
  2. Place extracted tissue in a cryo-vial, and snap freeze by placing in liquid nitrog....

Access restricted. Please log in or start a trial to view this content.

Results

Flow cytometry setup table: cell line info; unstained, CFP/YFP controls, tau biosensor analysis.

Table 1: Cell lines used with FRET flow cytometry. HEK 293T cells are used for flow cytometry setup. CFP single-positive cells are used for compensation (*). YFP single-positive cells are used to eliminate false FRET signal due to direct activation of YFP by.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
TBSSigmaT5912
Complete Protease Inhibitors (EDTA-free)Roche4693159001
Cryo-vialsSarstedt72.694.006
Analytical BalanceMettler ToledoXSE 105DU
Weighing BoatsFisher Scientific13-735-743
15 mL conical tubeUSA Scientific1475-0501
Omni Sonic Ruptor Ultrasonic HomogenizerOmni International18-000-115
Micro-Tip for Ultrasonic HomogenizerOmni InternationalOR-T-156
2-PropanolFisher ScientificA451
Noise Cancelling Ear MuffsFisher Scientific19-145-412
KimwipesFisher ScientificS47299
1.5 mL tubesUSA Scientific1615-5510
MicrocentrifugeEppendorf5424 000.215
DPBSLife Technologies14190-136
DMEMLife Technologies11965-084
Fetal Bovine SerumHyCloneSH30071.03
Penicillin-StreptomycinLife Technologies15140-122
GlutaMaxLife Technologies35050-061
Trypsin-EDTALife Technologies25300-054
50 mL Conical TubesPhenix ResearchSS-PH15
25 mL reagent resevoirsVWR41428-954
Multi channel pipetFisher ScientificTI13-690-049
96 well flat bottom platesCorning3603
Opti-MEMLife Technologies31985-070
Lipofectamine 2000Invitrogen11668019
96 well round bottom platesCorning3788
16% ParaformaldehydeElectron Microscopy SciencesRT 15710
PBSSigma-AldrichP5493
EDTASigma-AldrichED2SS
HBSSLife Technologies14185-052
Sorvall ST 40 CentrifugeThermo Scientific75004509
BIOLiner Swinging Bucket RotorThermo Scientific75003796
HemacytometerVWR15170-172
MACSQuant VYB Flow CytomterMiltenyi Biotec130-096-116
Chill 96 RackMiltenyi Biotec130-094-459
Flow Jo analysis softwareFlow Jo
20 uL pipet tipsRaininGPS-L10
200 uL pipet tipsRaininGPS-250
1 mL pipet tipsRaininGPS-1000
200 uL pipet tipsUSA Scientific1111-1800
5 mL serological pipettPhenix ResearchSPG-606180
10 mL serological pipettPhenix ResearchSPG-607180
25 mL Serological pipettPhenix ResearchSPG-760180

Tags