Method Article

Bioluminescence Imaging for Studying Calcium Transients in Drosophila Brain Structures

752 views

May 29th, 2025

In This Article

Abstract

Source: Lark, A. R., et. al., In Vivo Functional Brain Imaging Approach Based on Bioluminescent Calcium Indicator GFP-aequorin. J. Vis. Exp. (2016)

This video demonstrates real-time imaging of calcium dynamics using Green fluorescent protein-aequorin bioluminescence in Drosophila's deep brain structures.

Protocol

1. Imaging

  1. Setup
    1. Start the recording system by turning on the microscope, computer, camera, and drainage system and setting the room environmental controls to 25 °C.
    2. Open the Measurement and Automation Explorer program on the computer. Click on “Devices and Interfaces”, then double click on “NI Motion Devices,” and finally right click on “PCI-7334” and select “initialize device”.
    3. Open Photon Imager. Create a new folder and name the first recording file. The camera must reach -80 °C before the system will function.
    4. Set up the perfusion system: Add KCl (potassium chloride), nicotine, and Ringer’s solution to the reservoirs and adjust so each solution discharges at 2 ml/min. Wash with Ringer’s solution prior to starting the experiment.
  2. Prepare sample
    1. Place the imaging mount block dish on the mount under a microscope at 5X magnification and insert the perfusion tube into the channel through the puncture.
    2. Set the microscope to fluorescent mode, then center and bring mushroom bodies (MBs) into focus. Adjust to 20X, re-center, and focus.
    3. Position the drainage apparatus over the drainage pool, adjust the height of the drainage shunt so that the tip is just above the pool, and run Ringer’s solution for 30 sec to ensure adequate drainage.
    4. Pull down the shield to seal off the apparatus from light. Using the automated system in the photon imager, make fine adjustments to the focus and take a reference fluorescent image of the MBs.
  3. Recording
    1. Adjust photon speed to the desired recording speed (from 50 msec up to 1 sec or more). Select photon mode and open the shutter. Record genotype, sex, age, and sample number in log entries. Adjust the position of ROI (Region of interest) boxes over calyx and cell bodies (CCB) and medial lobes by clicking on the ROI boxes and dragging while holding control.
    2. Record baseline for about 5 to 10 min (as desired).
    3. Apply nicotine for 1 min. Note start/stop in the log. Wash with Ringer’s solution for 5 min.
    4. Wait 5 min for recovery and prepare KCl (potassium chloride) log entry and timer.
    5. Apply KCl for 1 min. Note start/stop in the log. Wash with Ringer’s solution for 1 min.
    6. Switch to fluorescent mode, take the final fluorescent image, and turn off the Ringer’s solution.
    7. Press “Stop.” A dialog box will ask if you want to shut off the system. Select “No” to continue recording.
    8. Open the shield, move the drainage system, switch the lens objective to 5X, and remove the perfusion tube. Remove the sample/recording dish from the stage, and clean off the 20X lens by rinsing and wiping the lens twice with water.
    9. Press the white play button at the top of the program window to initiate the next recording.

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Sodium chlorideSigma-AldrichS3014
Calcium chlorideMerck1023911000
HEPESSigma-Aldrich7365-45-9
Potassium chlorideProlabo26 764.298
Magnesium chlorideProlabo25 108.295
SucroseSigma-AldrichS0389
NicotineSigma-AldrichN3876
ATPSigma-AldrichA2383Adenosine 5′-triphosphate disodium salt hydrate
Benzyl-coelenterazineProlume, nanolightCat #301 Coelenterazine hhttp://www.prolume.com/
Pipette tipsCorning Incorporated4868100-1000µL Univesal Pipette Tip
EM-CCD cameraAndorDU-897E-CS0-#BViXon (cooled to -80°C)
MicroscopeNikonN/AEclipse-E800
Immersion objective lensNikonN/A20x Fluor .5w
Dissection microscope with fluorescenceLeica MZ Fl IIIN/Aleica dissection scope and florescent lamp
Peristaltic pumpGilsonN/AMinipuls 2
TubingFisher ScientificDepends on thicknessTygon R3603, St-Gobain
Perfusion systemWarner64-0135 (VC-66CS)Perfusion valve control system, complete, with pinch valves, 6 channel
Perfusion regulatorsLeventon201108Dosi-flow 3
Measurement and automation explorerSciences Wares & National InstrumentsN/Asoftware http://sine.ni.com/nips/cds/view/p/lang/en/nid/1380
Photon imagerScience Wares & National InstrumentsN/Asoftware http://sine.ni.com/nips/cds/view/p/lang/en/nid/1380
Photon viewerScience Wares & National InstumentsN/Asoftware http://sine.ni.com/nips/cds/view/p/lang/en/nid/1380
ExcelMicrosoftN/Asoftware https://www.microsoft.com
Virtual dubopen accessN/Asoftware http://virtualdub.sourceforge.net/