A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Imaging Brain Damage Induced by Cerebral Hypoxia-Ischemia in a Mouse Model

827 views

June 17th, 2025

In This Article

Abstract

Source: Ouyang, Y., et al. Simultaneous PET/MRI Imaging During Mouse Cerebral Hypoxia-ischemia. J. Vis. Exp. (2015)

This video demonstrates a technique to assess cerebral hypoxia injury via simultaneous positron-emission tomography (PET) and magnetic resonance imaging (MRI). An anesthetized mouse undergoes common carotid artery (CCA) ligation, reducing blood flow to one brain hemisphere and predisposing it to hypoxia-induced injury. PET and MRI imaging evaluate glucose metabolism and structural changes during hypoxia. MRI detects restricted water diffusion, while PET reveals reduced glucose uptake, indicating hypoxia-induced cellular stress and metabolic impairment.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Unilateral Common Carotid Artery (CCA) Ligation

  1. Prepare sterile field with sterilized surgical tools and materials positioned conveniently. Ensure heating pad is warmed to 37 °C with temperature probe placed securely on the pad. Be sure to use a sterile drape to cover the surgical site.
  2. Anesthetize animal (isoflurane, 1-3% in air at 0.5-1 L/min), and place animal in a supine position with the tail facing away. Check anesthetization by pinching the toe - this should elicit no reaction if the animal....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Surgery
Surgical scissorsRobozRS-5852
ForcepsRobozRS-5237
Hartman mosquito forcepsMiltex7-26
2x McPherson suturing forceps, 8.5 cmAccurate Surgical & Scientific Instruments4473It is useful to reduce the opening width with a band on the forceps used to hold the carotid artery
6-0 silicone coated braided silk suture with 3/8 C-1 needleCovidien SofsilkS-1172
Homeothermic blanket systemHarvard Apparatus507220F
Super glue(Generic)
Hypoxia
Flowmeter for O₂Alicat ScientificMC-500SCCM-D
Flometer for N₂Alicat ScientificMC-5SLPM-D
O₂ meterMSAAltair Pro
Imaging
7.05 Tesla MRI SystemBrukerBioSpec20 cm inner bore diameter with gradient set. Paravision 5.1 software.
Volume Tx/Rx 1H Coil, 35mm IDBrukerT8100
PET system(In-house) 4x24 LSO-PSAPD detectors,
10x10 LSO array per detector,
1.2mm crystal pitch and 14mm depth. 14 x 14 mm PSAPD. FOV: 60x35mm. 350-650 keV energy window. 16 ns timing window.
Vessel cannulation Dumont forcepsRobozRS-4991
PE-10 polyethylene tubingBD Intramedic427401
Infusion pumpBraintree ScientificBS-300
Animal monitoring & gating equipmentSmall Animal Instruments Inc.Model 1025Only respiration monitoring used
Animal bed with temperature regulation(In-house)

Tags

PET MRI ImagingCommon Carotid Artery LigationGlucose Metabolism AnalysisDiffusion Weighted ImagingRadiolabeled Glucose UptakeHypoxia Induced DamageSimultaneous PET MRIBrain Hemisphere Injury