Mechanical Testing of Mouse Carotid Arteries: from Newborn to Adult

12.7K views

⸱

DOI:

10.3791/3733

⸱

February 23rd, 2012

 ,  , 

In This Article

Summary

Passive mechanical testing of mouse carotid arteries is described, with special consideration for adapting to different specimen ages. The procedures include determining the in vivo length of the artery, mounting it in a pressure myograph, recording data, measuring the unloaded dimensions and analyzing the resulting data.

Abstract

The large conducting arteries in vertebrates are composed of a specialized extracellular matrix designed to provide pulse dampening and reduce the work performed by the heart. The mix of matrix proteins determines the passive mechanical properties of the arterial wall1. When the matrix proteins are altered in development, aging, disease or injury, the arterial wall remodels, changing the mechanical properties and leading to subsequent cardiac adaptation2. In normal development, the remodeling leads to a functional cardiac and cardiovascular system optimized for the needs of the adult organism. In disease, the remodeling often leads to a negative feedback cycle that can cause cardiac failure and death. By quantifying passive arterial mechanical properties in development and disease, we can begin to understand the normal remodeling process to recreate it in tissue engineering and the pathological remodeling process to test disease treatments.

Mice are useful models for studying passive arterial mechanics in development and disease. They have a relatively short lifespan (mature adults by 3 months and aged adults by 2 years), so developmental3 and aging studies4 can be carried out over a limited time course. The advances in mouse genetics provide numerous genotypes and phenotypes to study changes in arterial mechanics with disease progression5 and disease treatment6. Mice can also be manipulated experimentally to study the effects of changes in hemodynamic parameters on the arterial remodeling process7. One drawback of the mouse model, especially for examining young ages, is the size of the arteries.

We describe a method for passive mechanical testing of carotid arteries from mice aged 3 days to adult (approximately 90 days). We adapt a commercial myograph system to mount the arteries and perform multiple pressure or axial stretch protocols on each specimen. We discuss suitable protocols for each age, the necessary measurements and provide example data. We also include data analysis strategies for rigorous mechanical characterization of the arteries.

Protocol

1. Pressure myograph set-up

  1. Summarized from the manufacturer instructions (Danish Myotechnology). A schematic of the complete system with optional accessories is shown in Figure 1.
  2. Turn on the air tank and myograph control boxes and start the MyoView software (Danish Myotechnology). In the software, load the appropriate diameter calibration file, inflation protocol file and name the file for saving data for the first protocol. Recommended inflation protocols for each age are given in Table 1.
  3. Choose the required cannulae and suture size for the test system depending on the mouse age. Dimensions of the custom-designed stainless steel can....

Access restricted. Please log in or start a trial to view this content.

Discussion

The protocol presented here provides a straightforward and repeatable method for characterizing the passive mechanical behavior of mouse carotid arteries. Although smooth muscle cells and endothelial cells are critical to the function of smaller, muscular arteries and capillaries, they do not contribute significantly to the mechanical behavior of large elastic arteries. Poisoning the cells with KCN has no significant effect on the pressure-diameter behavior of mouse carotid arteries17. Passive mechanical chara.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Acknowledgements

This work was funded, in part, by NIH grants HL087653 and HL105314. Some of the methods described in this work were developed in the laboratory of Dr. Robert Mecham at the Washington University School of Medicine.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Name of the reagent/equipmentCompanyCatalogue numberComments
Air tank and regulatorAirgas Mid AmericaUN3156For pressurizing myograph
Pressure myograph and software Danish Myotechnology110P, MyoViewWith custom cannulae (Figure 2)
Inverted microscope, 5x lens and cameraZeissAxiovert 40CFor tracking artery diameter
Physiological saline solution (PSS)Chemicals from SigmaRecipe and details in Table 2
Surgical tapeVarious suppliersFor securing the mouse during dissection
Dissection boardFisher Scientific09-002-24AFor securing mouse during dissection
Dissecting microscope with cameraZeissStemi
2000-C
For arterial dissection and mounting
Dissecting scissorsFine Science Tools14058-11For cutting skin and opening the chest
Fine tweezers (2)Fine Science Tools11200-14For grasping artery ends
Curved forcepsFine Science Tools11274-20For clearing tissue and exposing carotid arteries
Micro-scissorsFine Science Tools15005-08For precise cutting of arteries
7-0 and 10-0 silk sutureVarious suppliersFor estimating length and fastening arteries on cannulae
Digital calipersFisher Scientific806-93-111For measuring suture length and checking artery length
Disposable scalpelFeatherNo. 15For cutting artery rings
Activated charcoalSigmaC4386-500GFor marking cut locations on vessels
18G NeedleBeckton-Dickinson305136For applying activated charcoal to vessels, clearing blood and filling myograph tubing
20 mL syringeVarious suppliersFor clearing blood and filling myograph tubing
Petri dishFisher Scientific08-757-13BFor inserting vessels after dissection and testing to take pictures
Microfuge tubeFisher Scientific02-682-550For storing vessels before testing
Fine wireCalifornia Fine Wire Company100192For clearing clogged cannula
ImageJ softwareNational Health Institutewww. rsbweb.nih.gov/ijOpen-source image processing program developed by NIH
Matlab softwareMathworksUseful for analyzing data and fitting constitutive equations

References

  1. Dobrin, P. B. Chapter 3: Physiology and Pathophysiology of Blood Vessels. The Basic Science of Vascular Disease. Sumpio, B. E., Sidawy, A. N., DePalma, R. G. , Futura Publishing. New York. 69-105 (1997).
  2. Wagenseil, J. E., Mecham, R. P. Vascular extracellular matrix and arterial mechanics. Physiol. Rev. 89 (3), 957-989 (2009).....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Passive Arterial MechanicsBiaxial Mechanical TestsIn Vivo LengthEx Vivo LengthPressure ProtocolsAxial StretchDiameter TrackingUnloaded Dimensions