$$\rightleftharpoonup{xx}$$
$$\longleftharp{xx}$$,
$$\longrightharp{xx}$$,
Water is transported from plant roots to the leaves in a vascular tissue called xylem - a network of interconnected conduits, fibers, and living, metabolically active cells. Transport function of plant xylem must be maintained to supply nutrients and water to leaves for photosynthesis, growth, and ultimately survival. Water transport in xylem conduits can be disrupted when the xylem network is compromised by pathogenic organisms. In response to such infections plants often produce gels, gums, and tyloses as a means to isolate pathogen spread (e.g. McElrone et al 2008; 2010). Drought stress can also limit water transport in xylem. As plants lose water during prolonged drought, tension builds in the xylem sap. Water under tension is metastable (i.e. at a certain threshold the tension becomes great enough to cavitate water columns contained in xylem conduits). After cavitation occurs, a gas bubble (embolism) can form and fill the conduit, effectively blocking water movement (Tyree and Sperry 1989), a phenomenon analogous to decompression sickness (i.e. "the bends") in deep sea divers.
Despite the importance of xylem water transport for optimal plant function as demonstrated by a vast body of historical and contemporary literature on this topic (Tyree & Zimmermann, 2002; Holbrook et al., 2005), there are still aspects of xylem networks that remain elusive. Several research groups have recently begun utilizing High resolution x-ray computed micro-tomography (HRCT) to evaluate finer details of wood anatomy and vascular tissue (e.g. Mayo et al; 2010, 2008; Mannes et al. 2010; Brodersen et al. 2010, 2011, 2012a,b; Maeda and Miyake, 2009; Steppe et al. 2004). HRCT is a nondestructive technique used to visualize features in the interior of solid objects and to obtain digital information on their 3-D structural properties. HRCT differs from conventional medical CAT-scanning in its ability to resolve details as small as a micron in size, even for high density objects. Recent advances in synchrotron HRCT technology have improved image resolution and signal to noise ratio sufficiently so that plant vessel networks and intervessel connections can be visualized, assigned 3D coordinates, and exported for hydraulic model simulations. Brodersen et al. (2011) recently advanced this technique by combining 3D reconstructions generated by synchrotron HRCT with a Fortran model that automatically extracts data from the xylem network at much higher resolution than was ever possible with traditional anatomical methods (i.e. serial sectioning with a microtome and image capture with light microscopy, e.g. Zimmermann 1971). This work has also been used to optimize hydraulic models of the xylem system and identified unique characteristics of transport (i.e. reverse flow in some vessels during periods of peak transpiration) (Lee et al., in review).
Synchrotron HRCT can now be used to visualize xylem functionality, susceptibility to cavitation, and a plants' ability to repair embolized conduits. Failure to re-establish flow in embolized conduits reduces hydraulic capacity, limits photosynthesis, and results in plant death in extreme cases (McDowell et al. 2008). Plants can cope with emboli by diverting water around blockages via pits connecting adjacent functional conduits, and by growing new xylem to replace lost hydraulic capacity. Some plants possess the ability to repair breaks in the water columns, but the details of this process in xylem under tension have remained unclear for decades. Brodersen et al. (2010) recently visualized and quantified the refilling process in live grapevines using HRCT. Successful vessel refilling was dependent on water influx from living cells surrounding the xylem conduits, where individual water droplets expanded over time, filled vessels, and forced the dissolution of entrapped gas. The capacity of different plants to repair compromised xylem vessels and the mechanisms controlling these repairs are currently being investigated.
Description of the ALS facility Beamline 8.3.2
Our work to date has been conducted on the Hard X-ray Micro-Tomography Beamline 8.3.2 at the Advanced Light Source in Lawrence Berkeley National Lab (Berkeley CA USA). Plant samples are placed in a lead-lined hutch located 20 m from the x-ray source, generated by a 6 Tesla superconducting bend magnet dipole within the Advanced Light Source electron storage ring operating at a critical energy of 11.5 KeV. A schematic of the end station is shown in Figure 1. The x-rays enter the hutch with a beam size of 40x ~4.6 mm and pass through the sample that is mounted on a motorized rotating stage. The transmitted x-rays impinge on a crystal scintillator (two materials commonly used are LuAG or CdWO4) which convert x-rays to visible light that is relayed via lenses onto a ccd for image collection. The camera, scintillator and optics are contained in a light tight box that is on rails that allows the sample-to-scintillator distance to be optimized for phase contrast imaging.
All samples are mounted on the 10 cm diameter rotary stage which in turn is mounted on horizontal and vertical translation stages for sample positioning. A living plant sample, with the root system mounted in a custom built plant pot holder and the foliage contained in an acrylic tube, can be seen in Figure 2. Typical exposure times can range from 0.1- 1 sec using 10-18 KeV, and scan durations will range from 5-40 min depending on the settings optimized for a particular sample. For tall samples (typical of plant xylem networks), data scans can be tiled by repeating the measurement with the sample at different heights, which is controlled automatically, allowing seamless serial sections along a maximum sample height of ~ 10 cm. Maximum sample width when imaging at 4.5 μm resolution is ~1 cm for samples that are nearly perfect in vertical orientation. Data generation and processing is completed using the protocol listed below. Because of the difference in x-ray attenuation between air and water, excellent image contrast can be obtained in plants without the use of contrast solutions typical of medical CT systems. The air-filled vessel lumen is easily distinguishable from the surrounding water-filled tissue in hydrated plants.