A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Diagnostic Ultrasound Imaging of Mouse Diaphragm Function

16.3K views

āø±

DOI:

10.3791/51290

āø±

April 21st, 2014

Ā ,Ā Ā ,Ā 

In This Article

Summary

Diagnostic ultrasound imaging has proven to be effective in diagnosing various respiratory diseases in human and animal subjects. We demonstrate a comprehensive ultrasound protocol utilized by Dr. Zuo's lab to analyze diaphragm kinetics specifically in mouse models. This is also a non-invasive research technique which can provide quantitative information on mouse respiratory muscle function.

Abstract

Function analysis of rodent respiratory skeletal muscles, particularly the diaphragm, is commonly performed by isolating muscle strips using invasive surgical procedures. Although this is an effective method of assessing in vitro diaphragm activity, it involves non-survival surgery. The application of non-invasive ultrasound imaging as an in vivo procedure is beneficial since it not only reduces the number of animals sacrificed, but is also suitable for monitoring disease progression in live mice. Thus, our ultrasound imaging method may likely assist in the development of novel therapies that alleviate muscle injury induced by various respiratory diseases. Particularly, in clinical diagnoses of obstructive lung diseases, ultrasound imaging has the potential to be used in conjunction with other standard tests to detect the early onset of diaphragm muscle fatigue. In the current protocol, we describe how to accurately evaluate diaphragm contractility in a mouse model using a diagnostic ultrasound imaging technique.

Introduction

Recently, diagnostic ultrasound imaging techniques have been applied to mouse models of renovascular hypertension and pancreatic cancer1,2.Ā However, these techniques have not been widely used in rodent respiratory muscle function assay. Therefore, we have developed a diagnostic ultrasound imaging method as a valuable tool for in vivo longitudinal assessments of diaphragm mobility in mice.

There are several advantages to diagnostic ultrasound imaging. For instance, it is noninvasive, safe, portable, and allows for real time measurements at a relatively low cost3. Particularly, certain low frequency ultraso....

Access restricted. Please log in or start a trial to view this content.

Protocol

All procedures involving animal subjects were approved and completed in accordance and compliance with The Ohio State University Institutional Animal Care and Use Committee (IACUC) regulations and guidelines.

1.Ā Mouse Anesthesia

  1. Set up a clean procedure table with a heated isothermal pad wrapped in a surgical towel. The heating pad should be maintained between 30 °C and 34 °C to stabilize the animal's core temperature while reducing potential stress to the animal.
  2. Place the mouse in an anesthesia induction chamber with the following parameters: oxygen flow rate set to 1.5 L/min and isoflurane vaporiz....

Access restricted. Please log in or start a trial to view this content.

Results

A typical ultrasound image of a mouse diaphragm is shown in FigureĀ 1A. The mouse diaphragm maximal vertical displacement was recorded. This distance was calculated by precisely measuring the depth of diaphragm movement from relaxation to contraction using the electronic calipers that are part of the ultrasound software. Table 1 displays these distance measurements of diaphragmatic contractions from three different mice. After converting the cine loop file into a MPEG file, the respiratio.......

Access restricted. Please log in or start a trial to view this content.

Discussion

The current experimental protocol develops diagnostic ultrasound imaging techniques specific to the diaphragm activity in a mouse model via a non-invasive, in vivo approach. The anesthesia apparatus settings are approximated values, which may be slightly adjusted for each animal since individual mice may respond differently to anesthesia. To prevent improper anesthesia administration, it is important to regularly monitor the mouse's vital signs including the heart rate, respiration rate, and body temperature.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors declare that they have no competing financial interests.

Acknowledgements

This work is supported by grants of OU General Fund G110 and Research Excellence Fund of Biomedical Research and OSU-HRS Fund 013000. The authors would like to thank Lauren Chen for her assistance in preparing this manuscript.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Veterinary digital ultrasonic diagnostic imaging systemEdanDUS 3 VETUltrasound parameters include: frequency of 6.5 MHz, Depth of 29 mm. Note: An equivalent ultrasound machine may be used for this protocol
Micro-convex array transducerEdanC611Or equivalent
GE Logiq i hand-carried unit (HCU)Ā GE HealthcareGE Logiq i hand-carried unit (HCU)Or equivalent
GE 12 MHz linear array probeGE Healthcare12L-RSOr equivalent
Veterinary anesthetic vaporizerWebster VeterinarySerial #: W422021Isoflurane was exclusively used with this vaporizer (or equivalent). A custom made induction chamber for anesthesia was assembled for initial anesthesia. Maintenance anesthesia was performed using a nose cone
Isothesia (Isoflurane, USP)Butler Schein29405 250ML PVLOr equivalent
Enviro-pure anesthesia absorbing canisterSurgivet Smiths Medical PM, Inc.Part #: 32373B10Or equivalent
Ultrasound transmission gelHM SonicN/AOr equivalentĀ 
Puralube vet ointmentPuralubeNDC 17033-211-38Or equivalent
Deltaphase isothermal padBraintree Scientific Inc.39DPOr equivalent
Hair removerNairN/AOr equivalent
Electric razorRemingtonHC-5015Or equivalent
Surgical tape3M Micropore1530-1Or equivalent
Gauze spongesDynarex3262Or equivalent

References

  1. Snyder, C. S., et al. Complementarity of ultrasound and fluorescence imaging in an orthotopic mouse model of pancreatic cancer. BMC Cancer. 9, 106(2009).
  2. Franchi, F., et al.

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Diaphragm ContractilityRespiratory RateDiaphragm ExcursionAnesthesia ProcedureHair RemovalUltrasound GelElectronic CalipersM Mode Imaging