In vivo bioluminescent and fluorescent imaging
In the present study, the protocol is described for this previously published model of an orthopaedic prosthetic joint infection in mice14-19, which involves the surgical placement of a titanium K-wire implant that extends from an intramedullary canal in the femur into the joint space14-19. S. aureus bioluminescent strain Xen29 (1 x 103 CFU in 2 μl PBS) was pipetted directly on top of the end titanium implant in the knee joint prior to closing the surgical site16. To visualize and quantify the bacterial burden and neutrophil influx noninvasively in anesthetized LysEGFP mice, in vivo whole animal optical imaging was performed to sequentially image the bioluminescent signals from the bacteria and the EGFP fluorescent signals from the infiltrating neutrophils using the IVIS Spectrum optical whole animal in vivo imaging system on three postoperative days (i.e., days 2, 14 and 28). The bioluminescent signals of Xen29-infected mice remained above background signals of sham-infected mice for the duration of the experiment (Figure 1A,C)16. Our previous work demonstrated that the in vivo bioluminescent signals closely approximated the numbers of ex vivo CFU isolated from the joint/bone tissue and adherent to the implants17,18. In addition, the EGFP fluorescent signals were higher than sham-infected mice at early time points but approached background levels during the course of infection (Figure 2B,C)16.
3D co-registration of in vivo optical signals with μCT images
To visualize the optical signals (i.e., bacterial bioluminescent and EGFP fluorescent signals) in the anatomical context of the post-surgical knee joints in 3D, the optical images generated using the IVIS Spectrum imaging system were co-registered with μCT images generated using the Quantum FX μCT imaging system. This co-registration could be accomplished because the mouse imaging chamber could be inserted into either machine to ensure that the mice were in the exact same orientation. To verify this accuracy, the results were compared with an image acquisition performed using the IVIS Spectrum-CT in vivo imaging system that integrates both modalities into one instrument without requiring physical relocation of the animal. To map the optical data onto the μCT images in 3D, we utilized a diffuse optical tomography reconstruction algorithm16. The resultant 3D reconstruction is shown (Movie 1).
In addition, μCT imaging allowed the visualization and quantification of the consequential changes in the quality and dimensions of the bone that occurred during the infection (Figure 2)16. As previously reported, the outer bone volume of the distal femur substantially increased over time (Figure 2A) 16. To quantify these changes, 3D volumetric image analysis was performed on the distal 25% of the boney surface of the femur and the changes in the bone volume over time were normalized to the initial bone volume. The outer bone volume substantially increased in infected mice compared to sham-infected mice (Figure 2B)16. The increase in the distal femur outer bone volume was likely due to bone damage caused by the infection of the joint tissue and bone, which were observed using μCT imaging and histologic analysis16.

Figure 1. 2D in vivo bioluminescent and fluorescent signals. S. aureus Xen29 or no bacteria (uninfected) were inoculated into the knee joint after K-wire placement and LysEGFP mice were imaged using the IVIS Spectrum imaging system16. (A) Mean in vivo bioluminescent signals as measured by total flux (photons/sec) ± sem. (B) Mean in vivo EGFP fluorescent signals as measured by total radiant efficiency (photons/sec) / (µW/cm2) ± sem. (C) Representative in vivo bioluminescent and fluorescent signals overlaid onto a black and white photographic image of the mice. The limit of detection of the bacterial burden using in vivo bioluminescent imaging is between 1 x 102 and 1 x 103 CFU. *p < 0.05, †p < 0.01, ‡p < 0.001 Xen29-infected mice versus sham-infected mice (Student’s t-test [two-tailed]). Please note this is a representative figure that includes previously published data generated using Xen29 and imaged with the IVIS Lumina XR imaging system16. Please click here to view a larger version of this figure.

Figure 2. 3D μCT imaging. S. aureus Xen29 or no bacteria (uninfected) were inoculated into the knee joint after K-wire placement and mice were imaged using the Quantum FX in vivo μCT system. (A) Representative 3D μCT renderings of Xen29-infected mice (upper panels) and sham-infected mice (lower panels). (B) Percentage of outer bone volume change (distal 25% of the femurs) normalized to the initial time point (mean ± sem). *p < 0.05, †p < 0.01, ‡p < 0.001 Xen29-infected mice versus sham-infected mice (Student’s t-test [two-tailed]). Please note this is a representative figure that includes previously published data generated using the bioluminescent strain S. aureus Xen29 and imaged with the Quantum FX in vivo µCT imaging system16. Please click here to view a larger version of this figure.
Movie 1. Representative 3D anatomical co-registration of the Xen29 bioluminescent signals and the EGFP-neutrophil fluorescent signals in combination with the μCT images. The images are rotated on the vertical axis.