Latex agglutination is a simple, quick and inexpensive method for pneumococcal serotyping. Commercial pneumococcal latex agglutination reagents are available, but they currently do not differentiate all known pneumococcal serotypes10,12. However, latex agglutination reagents can be easily produced in-house using purchased antisera raised against specific pneumococcal capsular antigens. In the method described here, antibodies are passively attached to latex particles to make a set of latex agglutination reagents.
A positive latex reaction occurs when specific antibodies bound to the latex particles attach to antigens on the polysaccharide capsule of the pneumococcal isolate 18,19. The latex particles attached to the antibodies allow the specific antibody-antigen reaction to be visualized without magnification.
Latex agglutination is a suitable method for high throughput laboratories and also for resource-poor settings. Key advantages of the latex agglutination method are that no specialized equipment is required to perform the test, reagents have a shelf life of at least 2 years when stored at 4 °C8, and that it is inexpensive, simple and quick to perform. Serotyping a pneumococcal isolate by latex agglutination takes approximately 10 min, and up to four latex reagents can be tested in parallel on the one slide. Furthermore, if the prevalence of serotypes is known for the relevant epidemiological setting, testing can be performed in rounds starting with the pools containing the most common serotypes similarly to the Quellung test17. This approach minimizes the number of tests needed to determine the serotype. The method is also highly reproducible between different operators (data not shown). A disadvantage of latex agglutination serotyping is that producing the reagents is time consuming, taking approximately 4 hr; although multiple reagents can easily be produced in parallel. Furthermore, some antigens are common across different pneumococcal serotypes, resulting in cross-reactions with some antisera (e.g., serotype 29, 42 and Group 35). However, these cross reactions are well characterized when using commercial antisera (which is usually preabsorbed to remove the more problematic cross-reacting antibodies) and additional reaction tables are provided by the manufacturer in order to distinguish which serotype is present. Latex reagents may also cross react if the antibodies are not aligned properly on the latex particles; these are detected as QC failures. In our experience, rigorous QC is central to the success of this method, even when commercially available antisera are used for production. QC takes approximately 15 min per reagent and relies on a set of appropriate QC isolates as described above.
The method described here results in reagents that give a positive reaction well within the test period. In our experience, false positives are rare in practice (data not shown). Occasional false negative reactions are observed; usually these relate to known issues with a particular antiserum (e.g., serogroup 6 isolates may not react with pool B antiserum), or down regulation of capsule expression by the isolate. Using the serotyping algrorithm provided by the manufacturer is also important, as in most cases a false positive or negative reaction will lead to a ‘blind end’ result. In these cases, and when reactions are difficult to interpret, we recommend repeat-testing and/or testing by an alternative method such as the Quellung reaction.
Some troubleshooting is occasionally required to make satisfactory latex reagents. In the method described here, the antibody is attached to latex particles via passive adsorption15,19, so a critical variable is the concentration of antibody used, which determines how well the surface of the latex particles is covered and the subsequent alignment of the antibody active sites15,20. Consequently, if insufficient or excess antibody is attached to the latex particles, the antibody-antigen reactions will not be optimal, and unsatisfactory reagents may be produced15,20,21. As antibody titers vary between different lots of antisera, a standard set of dilutions may not produce reagents that perform well8. A useful starting point is to use a 1:40 dilution of antiserum, and if this is not successful, dilute the antiserum further. In our experience this usually resolves the problem8. In a small number of cases reagents may show weak agglutination that is not accompanied by clearing of the suspension when tested with target isolates. In these cases diluting the antiserum does not improve the quality of the reagent, but satisfactory reagents can usually be produced by omitting the centrifugation and wash steps8,22.
Antibody coated latex particles are used commonly in diagnostic microbiology for detection, identification or serotyping of many different microbes15,20. As such, the method described here may be suitable for preparing latex reagents for other purposes, provided suitable antisera is available and adequate QC procedures are adopted.