Lung dysfunction is one of the leading causes of morbidity and mortality in the world. The condition is characterized by inadequate oxygen exchange, synonymous with coughing, chest pains and dyspnea. Respiratory disease accounts for ~10% of mortality worldwide1. According to the World Health Organization, mortality rates are set to rise due to persistent smoking, pollution & occupational irritants. UWBP is a useful addition for studying lung physiology, which strongly compliments traditional biochemical and histological analyses2. Other procedures used for lung assessment do not provide the same advantages as UWBP. Invasive plethysmography is a commonly used technique that requires the animal to be anesthetised3,4 and thus, resulting respiratory measurements are not necessarily reflective of a natural state. Further, the requirement for mechanical ventilation and chemical challenges preclude future measurements3,4. Another method of collecting respiratory data is by forced oscillation, which is more sensitive to finer changes in respiratory parameters compared to UWBP5. Forced oscillation is, however, an invasive technique and requires animal termination for data collection5-7.
UWBP involves placing an animal inside a specialized chamber. During inspiration, the tidal air is warmed and humidified within the lungs increasing water vapor pressure and causes thermal expansion of gas8. This effect causes a net change in air volume creating an increase in pressure within the plethysmograph chamber8. The opposite occurs during expiration creating a respiratory waveform from the animal. Waveform analysis is then used to measure from the respiratory trace: respiration rate (breaths/min), total breathing cycle time (sec), inspiration/expiration time (Ti/ Te, sec) and changes in pressure due to each tidal volume (PT). Figure 1 illustrates each measurements origin from a respiratory trace. These measurements are simple to calculate and multiple respiratory parameters may be derived from these measurements. These parameters include: Tidal volume (the volume of air moved between normal inhalation and exhalation), minute volume (volume of gas inhaled from the lungs per minute), inspiratory duty cycle (the percentage of inspiration time to the total breathing cycle duration) and inspiratory flow rate (the amount of air inspired in a given time).
UWBP provides precise, non-invasive, quantitative analysis of respiratory physiology in animal models and can be used for measuring the progression of respiratory disease and lung function6,9. Contrary to other plethysmography techniques, UWBP avoids the use of anesthesia, restraints and invasive manipulations that produce artefacts and experimental variability6,9. Anesthesia can suppress respiration, alter heart rate and can be challenging to regulate10. Restraints induce an increase in respiration due to additional stress via corticosterone and epinephrine release11,13. The key feature of UWBP is repeated physiological assessment making it amenable to longitudinal studies. UWBP is strongly recommended for the longitudinal assessment of lung physiology and offers a valuable skill for future respiratory drug assessment.
Bleomycin, ovalbumin, and hypoxia have been utilized to induce respiratory challenges in several studies and UWBP has successfully measured accurate lung physiological assessment7,9,13-16. The protocol described is designed for standard adult laboratory mice. However, UWBP has been adapted to other animals such as rats, guinea pigs, and non-human primates17-20. UWBP is not restricted only to assessing pulmonary dysfunction but has also been used for the assessment of lung maturation3. The versatility, simplicity and reproducibility of UWBP have established an excellent technique for assessing pulmonary function in animals. Various software (see materials and equipment table) will be required to follow this procedure. An experienced scientist would be able to perform this protocol with a mouse within 1 hr.