Morbidity rates for cardiovascular diseases are the largest in America, with many resulting from unhealthy vasculature. Healthy arteries consist of elastic tissue, with soft luminal surface coated with an endothelial cell (EC) monolayer. Arterial flow may be modeled as an oscillating wave function with positive mean flow rate. The pulsatility index (PI) is the quotient of oscillation magnitude and mean flow (PI = (Max. - Min.) / Mean),1 and has been modeled in vitro with variable vessel elasticity.2 Arterial elasticity is important in storage of flow energy from heart contractions, dilating under systolic pressure, and plays a significant role in modulating blood flow PI. Because the heart maintains a consistent, pulsatile, volumetric flow, arterial expansion increases cross-sectional area, enhancing flow stability by reducing flow velocity, shear stress, and PI. Frequently, unhealthy arteries present changes to elasticity or compliance, displaying stiffening from vascular remodeling, scar tissue or calcification3,4. Additionally, other vascular disorders, such as neointimal hyperplasia (NIH),5 aneurysm and hypertension6 and vascular fibrosis4, may constrict vessel diameter. However, current drug treatment and device treatment of vascular diseases often neglect the importance of vessel wall compliance or blood flow dynamics in vascular disease which is often complicated by changes in vessel morphology and properties. Neither balloon angioplasty nor stenting answer the complication of wall elasticity7. Therefore, in vitro modeling of blood flows resulting from arterial disease and treatments is important in investigating disease pathologies and future efficacy of treatment. Herein, we describe a method of replicating physiological and pathological blood flow designed to determine cell response in vascular disease pathologies. Fluid flow causes shear stress at the vessel wall, which is an important mechanical signal in vessel health, affecting all cells within the vasculature. Several mechanical sensors on the vascular endothelium for fluid shear have been identified, including primary cilium shown in recent studies for endothelial mechanosensing8. Endothelial cell activity and morphology are affected by flow velocity, direction, and pulsatility. Additionally, smooth muscle cell (SMC) migration can be affected by mechano-signals of low velocity flow through interstitial fluid9, and can also be through the paracrine signaling from endothelial cells through their response to flow and mechano-transduction of flow signals via cytokine release10. The “dose” dependence of mean shear, PI, and paracrine signaling may also be interdependent. To this end, the determination of vascular cell response to fluid shear with varied “dosing” in monolayer culture or co-culture in vitro could provide mechanistic insights into vascular remodeling and improve disease and treatment prediction. The flow system used in this experiment consists of a blood pump, an upstream flow damping air reservoir, a downstream flow meter only used during experimental setup, a downstream cell culture, parallel-plate flow chamber, and media reservoir. Control of vascular flow variables such as mean flow rate, beats per minute, and PI may be achieved through controlling flow rate, pulse frequency, and introduction of pressure damping. Pulsatile blood pumps are available with variable stroke displacement, at controlled stroke frequency, relating directly to mean volumetric flow rate, and pulse frequency. Introduction of an air reservoir within the flow circuit allows for pressure damping, reducing flow oscillation magnitude. Media is an incompressible fluid, while air within the damping chamber is compressible, allowing excess pressure from the flow wave to be absorbed by air compression. The air to media ratio allows for control over how much damping occurs. A custom cell culture flow chamber 75 mm in length by 50 mm in width was created from acrylic. Flow enters through the inlet port, and expands through the inlet manifold, providing consistent flow across the entirety of the flow chamber. Similar flow and structures are present at chamber outlet. Cells are seeded onto functionalized slides, and subsequently attached to the flow chamber. This allows for large populations, easily retrieved after the study. Co-culture experiments may use a porous polycarbonate membrane to eliminate cell-to-cell contact between cultures while allowing cytokine/flow transport. This system has previously been used to model high PI flow and its effect on endothelial monolayer culture and EC/SMC co-culture1,10, to investigate cell response to pathologically high PI disease. By describing the protocol used to model these flow conditions, we hope to aid others in determining flow signal contribution to cell response.