A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Long-term Blood Pressure Measurement in Freely Moving Mice Using Telemetry

20.9K views

⸱

DOI:

10.3791/53991

⸱

May 17th, 2016

 ,  , 

In This Article

Summary

The goal of this protocol is to assess systemic blood pressure in conscious freely moving mice using implantable radio-telemetry devices.

Abstract

During the development of new vasoactive agents, arterial blood pressure monitoring is crucial for evaluating the efficacy of the new proposed drugs. Indeed, research focusing on the discovery of new potential therapeutic targets using genetically altered mice requires a reliable, long-term assessment of the systemic arterial pressure variation. Currently, the gold standard for obtaining long-term measurements of blood pressure in ambulatory mice uses implantable radio-transmitters, which require artery cannulation. This technique eliminates the need for tethering, restraining, or anesthetizing the animals which introduce stress and artifacts during data sampling. However, arterial blood pressure monitoring in mice via catheterization can be rather challenging due to the small size of the arteries. Here we present a step-by-step guide to illustrate the crucial key passages for a successful subcutaneous implantation of radio-transmitters and carotid artery cannulation in mice. We also include examples of long-term blood pressure activity taken from freely moving mice after a period of post-surgery recovery. Following this procedure will allow reliable direct blood pressure recordings from multiple animals simultaneously.

Introduction

Hypertension is one of the major risk factors for cardiovascular diseases, arguably it is a major public health issue both in developed and developing countries1. Several animal models of experimental hypertension have been developed to mimic hypertensive responses like those observed in humans2. Among others, the ambulatory mouse represents an excellent model to study the genesis and the progression of hypertension allowing in vivo analysis of the consequences of chronic exposure to hypertension.

Blood pressure (BP) monitoring in mice has helped researchers to unravel several mechanisms involved in the p....

Access restricted. Please log in or start a trial to view this content.

Protocol

Ethics statement: All animal procedures mentioned in this video-article were reviewed and approved by the Animal Care and Use Committee (IACUC) at the University of Tennessee Health Science Center.

Note: Use sterile microsurgery instruments throughout the surgical procedure. Surgical instruments may be sterilized utilizing an infrared sterilizer at an optimum sterilizing temperature of 1,500 °F (815.6 °C). Telemeters can be reused, however, before inserting it in the animal make sure to sterilize the entire transmitter according to the manufacturer instructions and that the tip of the catheter has been refilled with a special gel provided by the manufacturer.

Access restricted. Please log in or start a trial to view this content.

Results

Data can be acquired remotely by a receiver; traces are visualized on a computer screen for quality control (Figure 1a). Details such as animal ID, diastolic blood pressure and systolic blood pressure are also shown (Figure 1b). Arterial BP can be recorded continuously (24/7), or for short programmed intervals (i.e., 60 sec acquisition every hour). Data can be automatically stored in a hard disk for later analysis. Averaged BP data from a 3-day c.......

Access restricted. Please log in or start a trial to view this content.

Discussion

Implantable radio-telemetry has improved significantly over the last decade; smaller probe size makes the implant less traumatic for the animal, prolonged battery life helps to reduce the costs, and independent telemeter frequencies eliminate crosstalk between receivers. Telemetry is considered the state-of-the-art method for collecting a wide variety of physiological parameters from freely moving animals without the artifacts associated with the use of restraint, human interaction, or anesthesia that are required by oth.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have nothing to disclose.

Acknowledgements

This work was supported by the National Institutes of Health (NIH/NHLBI) [Grant no. HL114869] and the support from UTHSC to SM.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Small animal anesthesia systemKent Scientific Corp, Torrington, Connecticut, USAlow-flow small animal anesthesia system
Pad warmer and mouse termometerKent Scientific Corp, Torrington, Connecticut, USAallows monitoring body temperature, and homeothermic control in small animals
Binocular MicroscopeKent Scientific Corp, Torrington, Connecticut, USAKSCXTS-1121binocular body with boom stand pole and top LED
Hemostat ForcepsKent Scientific Corp, Torrington, Connecticut, USAINS750451used to clamp blood vessels or tag sutures
Small metal Clips, 7 mm, Stainless SteelKent Scientific Corp, Torrington, Connecticut, USAINS750344used for skin closure
Betadine solutionPurdue Products L.P., Stamford, CT, USANDC-67618-150-0110% povidone iodine topical solution
Normal saline solutionAbott Laboratories04930-04-10needed for preventing tissue from drying.
Nair (Hair remover lotion)needed for fur removal from the site of incision/surgery
Braide silk sutureTeleflex Medical OEM, Coventry, Connecticut, USASize 5.0, 6.0, 7.0
Ethanol271670% ethanol for disinfection
Spring scissors Fine Science Tool15000-10for minor dissection
Scissors (angled to side)Fine Science Tool14063-011No. 3 handle
Scalpel blade2976-0No. 10
Forceps (curved)Fine Science Tool11150-10for holding tissue
Forceps (straight)Fine Science Tool11151-10for holding tissue
Needle holder Fine Science Tool12002-12for suturing
Fine needle nose ForcepsFine Science Tool
IsofluraneHenry Schein Animal Health, Melville, New York, USAa general inhalation anesthetic agent
SterilizerBenchmark Scientific, 116 Corporate Blvd, South Plainfield, NJ, USAB1000sterilize surgical tools in 5-10 seconds using infrared heating
Gauze PadsJohnson & Johnson, New Brunswick, NJ, USAJJ8513to use for wound cleaning, prepping, scrubbing or dressing
Telemetry DeviceData Sciences International, St. Paul, MN, USADSI-PA-C10to record blood pressure in freely moving mice
Telemetry receiver system  coumpled with a PCData Sciences International, St. Paul, MN, USA
TubingInstech Laboratories, Plymouth Meeting, PA USABTPE-90
Vessel Cannulation Forceps, 13 cm, 0.5 mm ODWorld Precision Instruments503374special vessel cannulation forceps
Tissue adhesive3M Animal Care Products, St. Paul, MN, USANAC No.: 11380041use to close minor wounds, often eliminating the need for sutures and/or bandages
Weighing scale BB300precision analytical laboratory balance

References

  1. Danaei, G., et al. The preventable causes of death in the United States: comparative risk assessment of dietary, lifestyle, and metabolic risk factors. PLoS Med. 6 (4), e1000058(2009).
  2. Dornas, W. C., Silva, M. E. Animal models ....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Telemetry ImplantationCarotid Artery CannulationRadio Transmitter ImplantSubcutaneous Pocket CreationVessel Cannulation TechniquePost Surgery RecoveryContinuous Blood Pressure RecordingCircadian Rhythm Monitoring