This work presents the methodology of applying high intensity-focused ultrasound to block the action potentials of diabetic neuropathic nerves.
A subscription to JoVE is required to view this content. Sign in or start your free trial.
Method Article
This work presents the methodology of applying high intensity-focused ultrasound to block the action potentials of diabetic neuropathic nerves.
Nerve conduction block with a high intensity-focused ultrasound (HIFU) transducer has been performed in normal and diabetic animal models recently. HIFU can reversibly block the conduction of peripheral nerves without damaging the nerves while using an appropriate ultrasonic parameter. Temporary and partial block of the action potentials of nerves shows that HIFU has the potential to be a useful clinical treatment for pain relief. This work demonstrates the procedures for suppressing the action potentials of neuropathic nerves in diabetic rats in vivo using an HIFU transducer. The first step is to generate adult male diabetic neuropathic rats by streptozotocin (STZ) injection. The second step is to evaluate the peripheral diabetic neuropathy in STZ-induced diabetic rats by an electronic von Frey probe and a hot plate. The final step is to record in vivo extracellular action potentials of the nerve exposed to HIFU sonication. The method showed here may benefit the study of ultrasound analgesic applications.
Oral medications, acupuncture1, and electrical nerve stimulation2 have been used for the treatment of painful diabetic polyneuropathy. However, the side effects of the oral medications, invasive operation of acupuncture, and electrical nerve stimulation hamper the therapeutic efficacy and patient's adherence. Ultrasound block of peripheral nerves in animal models has been investigated for decades3,4,5. The conduction of in vitro sciatic nerves of the large green frog was inhibited reversibly after the treatment of 1....
Access restricted. Please log in or start a trial to view this content.
The Institutional Animal Care and Use Committee of the National Health Research Institutes in Taiwan approved all animal protocols.
1. Induction of Diabetic Model in Male Adult Sprague - Dawley (SD) Rats
Access restricted. Please log in or start a trial to view this content.
The in vivo study demonstrated that, with an HIFU dose of 3 s sonication at an intensity of 2,810 W/cm2, the CMAPs were suppressed by 20% of baseline, but they were completely recovered after 30 min (Figure 2A, diamonds) and were almost constant in the period of 28 days (Figure 2B, diamonds). For the 5 s HIFU exposure at the same intensity, the CMAPs decreased to 65.4% (9.5%) of baseline at 4 min and recovered.......
Access restricted. Please log in or start a trial to view this content.
Partial and temporary suppression of action potentials of the neuropathic nerves from diabetic rats in vivo and instant occurrence of the blocking effect after HIFU treatment both were observed. The 28-day follow-up study on CMAPs demonstrated that a safe blockade of the nerve conduction could be carried out at an appropriate HIFU exposure. As a result, the above protocol of the HIFU treatment can provide an alternative solution for the reversible conduction block of sciatic nerves in diabetic rats.
Access restricted. Please log in or start a trial to view this content.
The authors have nothing to disclose.
The study was supported by the Ministry of Science and Technology (Project MOST 105-2221-E-400 -001) and the National Health Research Institutes (Project BN-105-PP-10), Taiwan.
....Access restricted. Please log in or start a trial to view this content.
| Name | Company | Catalog Number | Comments |
|---|---|---|---|
| streptozotocin | Sigma | 85882 | |
| citric acid monohydrate | Sigma | C1909 | |
| trisodium citrate dihydrate | Sigma | W302600 | |
| glucose meters | Roche Accu-Check Active | GC | |
| electronic von Frey device | IITC Life Science | 2390 | |
| hot plate | IITC Life Science | ||
| Biopac MP36 acquisition system | Biopac Systems, Inc. | ||
| HIFU transducer | Sonic Concepts | H108 | |
| function generator | Agilent | 33250A | |
| power amplifier | Electronics & Innovation | 1040L | |
| Rats | Biolasco taiwan | Sprague-Dawley | |
| Puralube vet ointment | Dechra | ||
| isoflurane vaporizer | Parkland Scientific | V3000PS | |
| Isoflurance | Attane | ||
| Restraint bag (Decapicones) | Braintree Scientific | DC 200 |
Access restricted. Please log in or start a trial to view this content.