The term "oxidative stress" is frequently cited as a mechanism in toxicology, yet rarely is this term described specifically. Oxidative stress can refer to several intracellular processes, including generation of reactive oxygen species, damage caused by free radicals, the oxidation of antioxidant molecules, and even the activation of specific signaling cascades. A broad range of environmental contaminants1,2 and pharmaceutical agents3,4 have been documented to induce oxidative stress by either direct action of the xenobiotic compound itself5,6 or secondarily by production of oxidant species as part of a cellular response7,8,9,10. It is therefore of great interest in toxicology to accurately observe and characterize the oxidative processes leading to adverse outcomes. Conventional methods of measuring oxidative stress involve identification of oxidized biomolecules11,12,13,14,15 or antioxidants16,17,18,19,20, or direct measurement of reactive species themselves21,22,23,24. However, these methods typically require cellular disruption, which often consumes the sample, eliminates spatial resolution, and potentially introduces artifacts25. The development of more sensitive and specific methods for the detection of oxidant species and markers of oxidative stress is broadly applicable to the investigation of the adverse effects of xenobiotic exposure.
Live-cell microscopy using a new generation of genetically-encoded fluorogenic sensors has emerged as a powerful tool to monitor the intracellular redox status of living cells. These sensors are typically expressed using a vector under the control of a viral promoter that is introduced via transfection or transduction methodologies. High expression efficiencies are not necessary, since cells expressing the fluorescent sensor can be easily identified visually. For toxicological assessments, cells expressing these sensors can be observed using fluorescence microscopy as they are exposed to xenobiotic compounds in real-time. This experimental design permits repeated measurements in the same cell, allowing each cell's established baseline to act as its own control. The high temporal resolution afforded by live-cell imaging is well-suited for the detection of oxidative events, particularly those that are modest in magnitude or transient in nature. In addition to being both sensitive and specific to their target molecules, the fluorescence of some of these sensors can be excited using two wavelengths of light. This phenomenon allows the fluorescent emission to be expressed as a ratio, which permits the discernment of signal changes associated with authentic sensor responses from those caused by artefacts such as variations in sensor expression, cell thickness, lamp intensity, photobleaching, and sensitivity of the fluorescence detector26. Another advantage of the use of fluorogenic sensors is that they can be targeted to specific cellular compartments, creating a level of spatial resolution that is unmatched by conventional methods25,26,27.
A large family of genetically-encoded sensors based on green fluorescent protein (GFP) have been developed and characterized to report on a broad variety of physiological markers, including pH, temperature, calcium concentrations, and the ATP/ADP ratio25,28,29,30,31. Included among these are sensors of the glutathione redox potential (EGSH) and hydrogen peroxide (H2O2). While these sensors were developed for applications in redox biology and physiology, they have also been adapted to study xenobiotic-induced oxidative stress. Specifically, the protocol outlined here describes the use of the EGSH sensor roGFP2 and the H2O2 sensor HyPer.
roGFP2 reports on the redox potential of intracellular reduced and oxidized glutathione (GSH/GSSG) through a redox relay involving glutathione peroxidase (GPx), glutaredoxin (Grx), and glutathione reductase (GR) (Figure 1)25,32,33. Glutathione is the predominant cellular antioxidant molecule and is present primarily in its reduced form (GSH) in millimolar concentrations in the cytosol25,34. While EGSH has not been linked to any functional outcome, it is recognized as an important indicator of intracellular oxidative status34. A relatively small increase in the concentration of GSSG results in an increase in EGSH that is detectable by roGFP2. Equally important, monitoring of EGSH using roGFP2 during xenobiotic exposures can potentially reveal much about the mechanism of action at several points in the redox relay and associated pathways, such as the pentose phosphate shunt (Figure 1)35. The second sensor discussed here, HyPer, is an intracellular H2O2 probe derived from the insertion of yellow fluorescent protein (YFP) into the regulatory domain of bacterial H2O2-sensitive transcription factor OxyR136. Although it has previously been considered a damaging reactive oxygen intermediate, H2O2 is increasingly being recognized as an important intracellular signaling molecule under physiological conditions37,38, suggesting that unrecognized roles for H2O2 exist in toxicology as well. For instance, excess H2O2 induced by a xenobiotic exposure could be a precursor to dysregulation in cellular signaling or a shift in bioenergetics.
Both genetically-encoded fluorogenic sensors have been expressed in several established cell lines, including the human epidermoid carcinoma cell line A431 and the human bronchial epithelial cell line BEAS-2B, to observe changes in EGSH and H2O2 in response to a variety of toxicological exposures. These include gaseous pollutants (ozone35), soluble components of particulate matter (1,2 naphthoquinone39,40 and zinc41), and nickel nanoparticles (unpublished data). These studies represent only a small subset of the possible applications of these two sensors. Theoretically, any cell type that is capable of receiving and expressing the DNA of these sensors through conventional molecular biology techniques can be utilized to assess the effects of xenobiotics suspected to alter the cellular oxidative state. To date, one or more of these sensors has been expressed in various prokaryotes and eukaryotes, including several mammalian, plant, bacterial, and yeast cell types25,26,36,42. The readout for both EGSH and H2O2 sensors is a change in the intensity of fluorescence emitted at 510 nm upon excitation with 488 and 404 nm light. This method is widely adaptable across fluorometric platforms, including various types of microscopy (confocal and wide-field) and plate readers. The method presented here allows for sensitive and specific observation of intracellular EGSH and H2O2 in in vitro toxicological systems.