A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

A Strain Gauge Monitor (SGM) for Continuous Valve Gape Measurements in Bivalve Molluscs in Response to Laboratory Induced Diel-cycling Hypoxia and pH

8.3K views

⸱

DOI:

10.3791/57404

⸱

August 1st, 2018

 , 

In This Article

Summary

Understanding the behavioral responses of bivalve suspension-feeders to environmental variables, such as dissolved oxygen, can explain some ecosystem processes. We have developed an inexpensive, laboratory-based, strain gauge monitor (SGM) to measure valve gape responses of oysters, Crassostrea virginica, to diel-cycling hypoxia and cyclical pH.

Abstract

An inexpensive, laboratory-based, strain gauge valve gape monitor (SGM) was developed to monitor the valve gape behavior of bivalve molluscs in response to diel-cycling hypoxia. A Wheatstone bridge was connected to strain gauges that were attached to the shells of oysters (Crassostrea virginica). The recorded signals allowed for the opening and closing of the bivalves to be recorded continuously over two-day periods of experimentally-induced diel-cycling hypoxia and diel-cycling changes in pH. Here, we describe a protocol for developing an inexpensive strain gauge monitor and describe, in an example laboratory experiment, how we used it to measure the valve gape behavior of Eastern oysters (C. virginica), in response to diel-cycling hypoxia and cyclical changes in pH. Valve gape was measured on oysters subjected to cyclical severe hypoxic (0.6 mg/L) dissolved oxygen conditions with and without cyclical changes in pH, cyclical mild hypoxic (1.7 mg/L) conditions and normoxic (7.3 mg/L) conditions. We demonstrate that when oysters encounter repeated diel cycles, they rapidly close their shells in response to severe hypoxia and close with a time lag to mild hypoxia. When normoxia is restored, they rapidly open again. Oysters did not respond to cyclical pH conditions superimposed on diel cycling severe hypoxia. At reduced oxygen conditions, more than one third of the oysters closed simultaneously. We demonstrate that oysters respond to diel-cycling hypoxia, which must be considered when assessing the behavior of bivalves to dissolved oxygen. The valve SGM can be used to assess responses of bivalve molluscs to changes in dissolved oxygen or contaminants. Sealing techniques to better seal the valve gape strain gauges from sea water need further improvement to increase the longevity of the sensors.

Introduction

Hypoxia, i.e., dissolved oxygen concentrations [DO] sufficiently low to negatively affect biological and ecological processes but often functionally defined as [DO] of < 2 mg/L1, and anoxia (functionally defined as [DO] of 0.0-0.2 mg/L) are occurring more frequently and severely in the world's coastal waters, estuaries and the deep ocean2,3 and are often exacerbated by increasing eutrophication4,5. With an increasing areal extent of hypoxia and anoxia, macrofauna are negatively affected and lose habitat extent and habit....

Access restricted. Please log in or start a trial to view this content.

Protocol

1. Construction of the Wheatstone Bridge for the Valve Gape Apparatus

NOTE: The strain gauge is nominally 1000 Ω, so to fully balance and null the bridge, all components should be 1000 Ω.

  1. As in Figure 1, solder two 1 kΩ precision resistors to each other and then to a ~976 Ω resistor and a 100 Ω 10 turn potentiometer. The typical strain gauge range is a few Ω off of the 1000 Ω nominal, so only this resistance needs to be matched. Use a fixed 976 Ω resistor and an adjustable resistor (10 turn potentiometer) for this purpose.
  2. Bring one side of the variable arm and one side of the 1 kΩ resisto....

Access restricted. Please log in or start a trial to view this content.

Results

Oysters exposed to uninterrupted normoxic estuarine water (no hypoxia during the low plateau phase of the daily cycle) were open most of the time and only briefly closed infrequently (Figure 5). When they closed varied from oyster to oyster. This pattern has also been found by Loosanoff and Nomejko 194644 and Higgins 198039. Oysters also did not respond to the difference in dark and light phases.

Access restricted. Please log in or start a trial to view this content.

Discussion

Typical studies focus on the continuous, extended time periods of low oxygen conditions and the response, often measured as the survival, of animals. However, at present, our understanding of the behavioral responses of animals to diel-cycling hypoxia is minimal63. Thus, more studies should focus on the behavior of organisms in response to diel-cycling hypoxia which occurs regularly over the summer in many estuaries7,8.

Access restricted. Please log in or start a trial to view this content.

Disclosures

We don't have anything to disclose.

Acknowledgements

We thank Melinda Forseth for taking photos of oysters and measuring their gape width in ImageJ. We thank Denise Breitburg for access to the aquaria with diel cycling hypoxia and cyclical pH conditions. We thank the Smithsonian Environmental Research Center, Edgewater, Maryland, for space for the experiments. The hypoxia experiments were funded by a National Oceanic and Atmospheric Administration - Center for Sponsored Coastal Ocean Research grant No. NA10NOS4780138 and the Smithsonian Hunterdon Fund to Denise Breitburg. The valve gape measurements during the hypoxia experiments were funded by a Faculty Enhancement Grant by Washington College to Elka T. Porter.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Campbell CR 10x data loggerCampbell Scientific, Logan, UtahOr other data logger. At Campbell the CR 10X has been replaced with the CR 1000
Campbell CR 10x multiplexerCampbell Scientific, Logan, UtahData logger needs to have space for 12 channels
Dsub connector male crimp pinsTE Connectivity205089-1pins for gape sensor leads
PCA tapeMicro Measurements Corp, NCTo seal the strain gauge
Duro Quick GelAce HardwareSuperglue
SG13/1000-LY43 or LY41Omega Engineering Inc., Stanford, CTStrain gauges
32 AWG (7/40) teflon Alpha wiresAlphaWire, Elizabeth, NJ2840/7Sensor cables, different colors are available
1/16" heat shrink tubingQualtekB01A3QKKO6To seal the leads of the sensor cable
Weller WES51 Analog Soldering StationAmazonLots of soldering, need a good soldering iron. https://www.amazon.com/Weller-WES51-Analog-Soldering-Station/dp/B000BRC2XU/ref=sr_1_23?s=hi&ie=UTF8&qid=1505654295
&sr=1-23&keywords=soldering+iron
Rosin Soldering Flux PasteAmazonNeeded for soldering
60-40 Tin Lead Rosin Core Solder WireAmazonNeeded for soldering
Aquarium sealantHome DepotAttach sensors to bivalve
PC LaptopAny old PC to run Campbell gape program
heat gunAmazonshrink shrink tubing
DrillHardware store, Amazonfor twisting wires to make sensor cables
AC to DC power moduleAcopianDB15-30Wheatstone bridge power supply
PoteniometerClarostat733AWheatsone bridge nulling
isolating BNC connectorSterren Electronics"200-148Wheatstone bridge output for multimeter
Fused AC receptical panel moduleAdam technologiesIEC-GS-1-200Wheatstone bridge power supply connector
976 ohm 1% resistorVishay DaleCMF50976R00FHEBWheatstone bridge resistor
1 kohm 1% resistorVishay DaleCMF501K0000FHEBWheatstone bridge resistor
Potentiometer scale dialKilo International46210 turn dial for nulling potentiometer
DB25 male panel connectorTE connectivity1757819-8Data logger connector on Wheatstone bridge
DB25 female panel connectorTE connectivity1757819-8Sensor connector to Wheatstone bridge
perforated circuit boardVector electronics64P44WEcircuit board for mounting of bridge components
enclosureHammond Manufacturing1444-29Enclosure for sensor readout electronics

References

  1. Vaquer-Sunyer, R., Duarte, C. M. Thresholds of hypoxia for marine biodiversity. Proceedings of the National Academy of Sciences of the United States of America. 105 (40), 15452-15457 (2008).
  2. Diaz, R. J., Rosenberg, R. Spreading dead zones and conseque....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Valve Gape BehaviorEastern OystersWheatstone BridgeSensor SealingAquarium SealantOxygen LevelsSensor Calibration