Knee osteoarthritis is frequently seen in the orthopedic department. We introduce in detail the entire knee osteoarthritis treatment process with platelet-rich plasma injection, including preparation, procedures, and evaluation.
A subscription to JoVE is required to view this content. Sign in or start your free trial.
Method Article
* These authors contributed equally
Knee osteoarthritis is frequently seen in the orthopedic department. We introduce in detail the entire knee osteoarthritis treatment process with platelet-rich plasma injection, including preparation, procedures, and evaluation.
Knee osteoarthritis (KOA) is one of the most frequently encountered diseases in the orthopedic department. Existing non-surgical treatments have a limited effect on the repair of cartilage and on bone regeneration. Platelet-rich plasma (PRP) is an autologous bioactive substance that can repair cartilage injury and accelerate bone regeneration effectively. However, reporting of PRP preparation protocols in clinical studies is highly inconsistent, with the majority of studies providing insufficient information to allow the protocol to be reproduced. We describe a repeatable method of preparing PRP visually, the treatment of KOA using PRP intra-articular injection, and methods of evaluating the outcome. PRP was prepared using manual double centrifugation. The PRP layer was extracted from peripheral blood and used for knee joint cavity injection. Evaluations included assessments of blood platelet concentrations and clinical outcomes. Preparation of PRP by manual centrifugation requires less apparatus and is less costly than plasma filtration or centrifugation using equipment. The centrifugation time of our double centrifugation method was 6 and 5 minutes for the respective centrifugations at forces of 800 and 1400 x g, respectively, to allow for the consistent preparation of standardized PRP. However, a manual method is susceptible to operator error, and PRP batch preparation is not available. Intra-articular injection of PRP proved to be an effective treatment for knee osteoarthritis. The entire treatment procedure took less than 30 minutes, the blood platelet concentration of PRP could be standardized, and treatment was proven to be effective when evaluated by follow-up.
Knee osteoarthritis (KOA) is one of the most frequently seen diseases in the orthopedic department; 30%-50% of people over the age of 65 years experience this disease1. At present, the conservative management of KOA mainly includes oral administration of non-steroidal anti-inflammatory drugs and cartilage nutrient drugs, intra-articular injection of sodium hyaluronate, and physiotherapy. However, these methods cannot stop the process of knee joint degeneration2. Articular cartilage defects can cause articular surface wear, joint instability, and metabolic changes, which are part of the pathogenesis of KOA
Access restricted. Please log in or start a trial to view this content.
The methods described were approved by the Ethics Committee of Guangdong General Hospital.
1. Obtain PRP by Manual Centrifugation
Access restricted. Please log in or start a trial to view this content.
As a result, the platelet count of the PRP reached a standard concentration level of 1121 x 103/µL. We conducted the 15 follow-up surveys described in the protocol on a 55-year-old male patient with early KOA. It was obvious that early clinical outcome was satisfactory after the intra-articular administration of PRP (Figure 2). However, medium-term efficacy was slightly inferior. A markedly significant analgesic effect was observed (
Access restricted. Please log in or start a trial to view this content.
The concentration of blood platelets in normal human blood is between 150,000/µL and 350,000/µL, and it is widely believed that blood platelet concentration of PRP should reach 1,000,000/µL, which is 3 to 5 times normal concentrations9. According to the PAW hierarchy system, it is believed that PRP has no obvious effect when the blood platelet concentration is less than three times the normal concentration, while PRP has an inhibiting effect when its blood platelet concentration is .......
Access restricted. Please log in or start a trial to view this content.
The authors have nothing to disclose.
This study was supported by the National Natural Science Foundation of China (81371991) and the Major Program of Science and Technology of Guangdong (2015B020225007).
....Access restricted. Please log in or start a trial to view this content.
| Name | Company | Catalog Number | Comments |
|---|---|---|---|
| Centrifuge | Eppendorf | 5702 | |
| Centrifuge tube | CORNING | 430828 | |
| Horizontal rotor | Eppendorf | LL080 | |
| Anerdian III | Shanghai Likang Disinfectant HiTech Co., LTD | 310173 | Disinfect the skin |
| 1ml Syringe | KDL Medical Equipment Co., LTD | 0.4*13 RWLB | |
| 10ml Syringe | KDL Medical Equipment Co., LTD | 1.2*38 TWSB | |
| 50ml Syringe | KDL Medical Equipment Co., LTD | 0.7*32 TWLB | |
| Medical Tourniquet | Changzhou Jinli Latex Products Co., LTD | 0087-2011 | |
| Single-use sterile rubber surgical gloves | Shanghai jinxiang Latex Products Co., LTD | 17060 | |
| Disposable Draw Blood Needle | KDL Medical Equipment Co., LTD | 0.55*20 L(II) RWLB | |
| Heparin Sodium Injection | SPH No.1 Biochemical & Pharmaceutical Co., LTD | 1706101 | 2ml:12500U |
| Jifro Hand Antiseptic Rinse Free Gel | Shanghai Likang Disinfectant HiTech Co., LTD | 311793 | |
| Medical Cotton Swab | Foshan Kangzheng Medical Supplies Co., LTD | KZ3-12 | Disinfect the skin |
| 10ml Normal Saline | Jiangxi Shuangshi Pharmecutical Co., LTD | 140211458 | |
| Automatic Blood Cell Analyzer | Beckman Coulter | LH-750 | |
| Hole-towe | Sterile | ||
| Anticoagulation Tube(Blood Collection Tubes, K2E 3.6mg) | Becton, Dickinson and Company | CNL17-COO56 | Store in a cool dry place within 4 to 25 degrees Celcius |
| Tweezers | RWD LIFE SCIENCE | F12006-10 | |
| Sterile Gauze | Guangdong Ze Chang Trade Co., LTD | 170915 | |
| Adhesive Plaster | 3M Transpore | 1527C-0 | |
| Skin Marker Pen | Guangzhou Mingjia Medical Device Manufacturing Co., LTD | 10110 |
Access restricted. Please log in or start a trial to view this content.