Three-Dimensional Printing of a Complex Aortic Anomaly

DOI:

10.3791/58175

November 1st, 2018

In This Article

Summary

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Here, we present a protocol to use three dimensional printed models for pre-operative planning and intra-operative reorganization of complicated vascular locations when handling a congenital aortic anomaly.

Abstract

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Complex congenital aortic anomalies include diverse types of malformations that may be clinically asymptomatic or present with respiratory or esophageal symptoms. These anomalies may be associated with other congenital heart diseases. It is hard to identify the accurate anatomic vessel location from two-dimensional imaging data, such as computed tomography. As an additive manufacturing method, three-dimensional (3-D) printing can covert the acquired imaging data into 3-D physical models. This protocol describes the procedure for modeling the volumetric DICOM imaging into 3-D data and printing it as an anatomically realistic 3-D model. Using this model, surgeons can identify the vessel location of complex aortic anomalies, which is helpful for pre-operative planning and intra-operative guidance.

Introduction

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Congenital aortic anomalies are extremely rare congenital malformations of the aortic arch system. They can be diagnosed either by imaging analysis or by evaluation of entities like dysphagia or subclavian steal1. In clinical scenarios, it is important to identify the anatomical anomaly in the confined surgical space that has limited visualization during the surgery2,3. Currently, conventional planar two-dimensional (2-D) imaging, such as computed tomography (CT) and magnetic resonance imaging (MRI), are usually presented to surgeons before the surgery. However, it is difficult for surgeons to image the anomaly based on the 2-D imaging. Consequently, they could encounter unpredictable difficulties while trying to separate the complex aortic vessels during surgery. Unpredictable injury to the vessel, the trachea and the esophagus could occur and result in disastrous outcomes.

In the last decade, 3-D imaging modeling has been used in cardiac surgery to help surgeons understand the complex anatomic anomaly4,5,6,7. Three-dimensional (3-D) printing technology can help convert the modeling data into a physical model. Compared with the digital reconstruction, 3-D printed physical models could present a better understanding of the anatomical details and provide an intuitional view of the malformation. For aortic anomaly surgery, the printed intuitional 3-D model is significant because poor understanding of aortic locations could be disastrous to patients. During the surgery, any mistake could lead to unpredictable bleeding and injury. Using the printed models, surgeons can fully understand the spatial relationships of aortic branches. During the surgery, the surgeons can also perform real-time review of the 3-D models to avoid confusion of the complex vascular locations.

Here, we present a protocol to apply 3-D printed models for pre-operative planning and intra-operative guidance while dealing with congenital aortic diseases. Kommerell's diverticulum, a type of complex congenital aortic anomaly, was selected as a case study. The steps include diagnosis based on computed tomography angiography (CTA) imaging, partitioning regions of interest, building 3-D models, preoperative surgical planning, and intra-operative reviewing of 3-D printed models8. This 3-D printing strategy could substantially reduce the risk of unpredictable tissue injury during the surgery.

Access restricted. Please log in or start a trial to view this content.

Protocol

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

The present study was approved by the ethics committee of Zhongshan Hospital Fudan University (B2016-142R) and all participants gave their informed consent.

1. Diagnosis of the Aortic Anomaly by Symptoms and Acquisition of Imaging Data

  1. Identify patients who have symptoms such as chest pain, dysphagia, or a blood pressure difference of the upper limbs in out-patient clinic. Exclude patients who may be intolerant of the operation.
  2. Perform CT angiography in these patients to diagnose Kommerell’s diverticulum8.

2. Segmentation of Regions of Interest

  1. Import all the CT angiography images into the software in a DICOM format. The resolution of these images was 512 × 512 pixels, and the slice thickness was 1 mm.
    1. Double click the patient case from case library and open it.
    2. Select the DICOM series and click Model Recon to open the model recon page.
  2. Have an engineer and a team of cardiac surgeons review the DICOM formatted raw data to identify key anatomic features and region of interest (ROI).
  3. Use gray value-based thresholding to segment the ROI.
    1. Click the Threshold Segmentation button and adjust the threshold range for the vascular mask. The default range is between 226 to 3071.
    2. Click the Confirm button for threshold segmentation and the vascular mask will show in the object list. Click the Recon button from the right of the mask and the 3-D vascular mask will be reconstructed and shown in 3-D viewer.
    3. Click the Threshold Segmentation button and adjust the threshold range for the trachea mask. Click the Marquee Segmentation button to limit the region of interest to the mediastinum and the lung. The default range is between -1024 to -520.
    4. Click the Mask Edit button and erase the connection between the trachea and the lung.
    5. Click the Region Grow button and select a seed by clicking any point/pixel at the mask in any one of the 2-D viewers. Check and confirm that the region grows as result, and that the trachea mask will show in the object list.
    6. Click the Recon button on the right of the mask, and the 3-D trachea will be reconstructed in the 3-D viewer.
  4. Save the ROI as masks for 3-D reconstruction.

3. 3-D Reconstruction of the ROI

  1. Adopt the gray value interpolation algorithm to calculate the surface mesh of the 3-D model. Make the surface a triangle to match the outmost voxels of the mask.
  2. Click the Export button to export the 3-D model as an STL file.
  3. Place the model on the center of the building platform. Orient the model by aligning the tangent of the vessel centerline at its extremity to be parallel to the Z axis of the building platform. Supports were automatically generated to the overhangs using the default parameters.
  4. Click the Slice | Save to save as a file ready for 3-D printing.

4. 3-D Printing

  1. Perform stereolithographic printing with a 3-D printer. Use the following parameters: a slice distance of 1 mm, a resolution of 512 × 512 pixels, a building layer thickness of 0.1 mm, and a laser spot diameter of 80 μm.
  2. Use ultraviolet light at 405 nm to harden the photosensitive resin by scanning the contours sliced by the software. The ultraviolet light laser speed is 3 m/s.
    NOTE: When one slice of the digital 3-D model was built, the building platform went up 0.1 mm for the next slice. The physical model was built layer by layer. The next layer was formed on top of the previous layer. The 3-D physical model was built layer by layer in this way.

5. Preoperative Planning and Intraoperative Review Using 3-D Printed Models

  1. Before the surgery, have surgeons make detailed and accurate surgical plans for each patient by learning the 3-D printed models.
  2. During the surgery, place the 3-D printed models in the operation room and have a nurse hold them. The anatomic details were reviewed by surgeons during the vascular location and separation.
    NOTE: The surgical treatment included resection of diverticulum and reconstruction of aortic branches. The impregnated woven polyester tube graft was applied to replace the resected aorta1,2,3,9. All patients were sent to cardiac surgery intensive care unit after surgery.

Access restricted. Please log in or start a trial to view this content.

Results

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Acquisition of CT angiography images, digital modeling and 3-D printing were all done in a hospital. Two hours were spent to get the 3-D model from the CT angiography image ready for the 3-D printing. Using the procedure and 3-D printer here, a patient-specific 3-D physical model can be sent to physicians quickly and the surgical decision can be made in time. The workflow from acquisition of CT angiography data to 3-D printing was shown in Figure 1. From the ...

Access restricted. Please log in or start a trial to view this content.

Discussion

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Congenital aortic anomalies comprise a rare spectrum of cardiovascular diseases, which often show complex aortic anomalies. Medical imaging, such as CT and MR, are required to elucidate complex aortic arch anomalies, the abnormal branching pattern, their relationship with the trachea and the esophagus, and other associated pathologies. Both CT and MR angiography can provide 2-D information of aortic vessel locations. With 3-D digital reconstruction of 2-D imaging, the anatomical relationship of the aortic vessels can be ...

Access restricted. Please log in or start a trial to view this content.

Disclosures

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

The authors have nothing to disclose.

Acknowledgements

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

The authors acknowledge funding from National Natural Science Foundation of China (No. 81771971), Shanghai Pujiang Program (No. 14PJD008 and 17PJ1401500), "Chen Guang" Project Supported by Shanghai Municipal Education Commission and Shanghai Education Development Foundation (No. 14CG06), Natural Science Foundation of Shanghai (Nos. 17411962800 and 17ZR1432900), and Science and Technology Commission of Shanghai Municipality (17JC1400200). W.Z. acknowledges funding from the National Natural Science Foundation of China (31501555 and 81772007, and 21734003), the China's 1000 Young Talents Program, Education Commission of Shanghai Municipality (Young Eastern Professorship Award), and Science and Technology Commission of Shanghai Municipality (17JC1400200 and 16391903900).

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
3D printerMeditool Enterprise Co., LtdFor 3D printing
Chaos Version 2.0Meditool Enterprise Co., LtdFor 3D segmentation and reconstruction

References

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,
  1. Tanaka, A., Milner, R., Ota, T. Kommerell's diverticulum in the current era: a comprehensive review. General Thoracic and Cardiovascular Surgery. 63 (5), 245-259 (2015).
  2. Rosu, C., Dorval, J. F., Abraham, C. Z., Cartier, R., Demers, P. Single-stage hybrid repair of right aortic arch with Kommerell's Diverticulum. The Annals of Thoracic Surgery. 103 (4), e381-e384 (2017).
  3. Idrees, J., et al. Hybrid repair of Kommerell diverticulum. The Journal of Thoracic and Cardiovascular Surgery. 147 (3), 973-976 (2014).
  4. Kankala, R. K., et al. Fabrication of arbitrary 3-D components in cardiac surgery: from macro-, micro- to nanoscale. Biofabrication. 9 (3), 032002(2017).
  5. Vukicevic, M., Mosadegh, B., Min, J. K., Little, S. H. Cardiac 3-D printing and its future directions. JACC Cardiovascular Imaging. 10 (2), 171-184 (2017).
  6. Yoo, S. J., Spray, T., Austin, E. H., Yun, T. J., van Arsdell, G. S. Hands-on surgical training of congenital heart surgery using 3-dimensional print models. The Journal of Thoracic and Cardiovascular Surgery. 153 (6), 1530-1540 (2017).
  7. Hermsen, J. L., et al. Scan, print, practice, perform: Development and use of a patient-specific 3-dimensionalprinted model in adult cardiac surgery. The Journal of Thoracic and Cardiovascular Surgery. 153 (1), 132-140 (2017).
  8. Sun, X., Zhang, H., Zhu, K., Wang, C. Patient-specific three-dimensional printing for Kommerell's diverticulum. International Journal of Cardiology. 255, 184-187 (2018).
  9. Ota, T., Okada, K., Takanashi, S., Yamamoto, S., Okita, Y. Surgical treatment for Kommerell's diverticulum. The Journal of Thoracic and Cardiovascular Surgery. 131 (3), 574-578 (2006).
  10. Agematsu, K., Ueda, T., Hoshino, S., Nishiya, Y. Rupture of Kommerell diverticulum after total arch replacement. Interactive Cardiovascular and Thoracic Surgery. 11 (6), 800-802 (2010).

Access restricted. Please log in or start a trial to view this content.