$$\rightleftharpoonup{xx}$$
$$\longleftharp{xx}$$,
$$\longrightharp{xx}$$,
The electrochemiluminescence immunoassay (ECLIA) is based on a process that utilizes labels designed to emit luminescence when electrochemically stimulated. It is a broadly applicable technique for the quantitative detection of biological analytes in basic industry and academic research, food industry as well as in clinical diagnostics1. Commonly, a disposable 96-well plate with carbon ink electrodes is used. These electrodes act as a solid-phase carrier for the immunoassay. A secondary antibody is conjugated to an electrochemiluminescent label and when electricity is applied to the system, light emission of the chemical label is triggered. An ultra-low noise charge-coupled device (CCD) records the light intensity which is directly proportional to the antigen bound to the capture antibody resulting in the quantification of the targeted analyte of the sample2. Compared to the enzyme-linked immunosorbent assay (ELISA), ECLIA is considered to be advantageous as it offers higher sensitivity and reproducibility as well as better automation and consistency3.
Here we analyzed the methyl-CpG binding protein 2 (MeCP2) levels in samples of human and murine origin as well as different variants of the recombinant protein using the newly developed ECLIA system. MecP2 is an X-linked nucleic acid-binding protein known to interact with methylated DNA sequences. This protein has been implicated in the regulation of gene expression4,5. Loss-of-function mutations in the gene which encodes this protein are the main culprits causing Rett syndrome (RTT), a severe neurodevelopmental disorder6. Another MeCP2-related disorder, MECP2 duplication syndrome, also leads to neurological symptoms that can overlap with those of RTT7. Notably, females are mostly affected by RTT while males are mostly afflicted by MECP2 duplication syndrome6,7.
These disorders are associated with insufficient or excess MeCP2 levels respectively in the central nervous system (CNS). Hence, treatment options for RTT that involve increasing MeCP2 levels in the CNS would need to avoid the detrimental effects associated with excess of MeCP27. Due to this fact, a highly sensitive and accurate quantification of MeCP2 protein levels, as provided by the ECLIA system, is crucial for the advancement of RTT as well as MECP2 duplication syndrome research. The precise measurements of endogenous and exogenous MeCP2 levels from human cell lines and mouse tissue samples as well as a recombinant protein consisting of human MeCP2 isoform B (also known as isoform e1), and a minimal N-terminal HIV-TAT transduction domain (TAT-MeCP2) that has the potential to cross the blood-brain-barrier8,9 are presented in this work.