The initial steps of extraction and isolation of the HA in this method are relatively straightforward. Because the isolation of the HFA involves column chromatography, obtaining repeatable results comes with strict adherence to the details of each step and practice. In particular, correct preparation of the resins is of primary importance. It is extremely important that the polymethylmethacrylate DAX-8 resin is prepared and packed properly. Correct packing of the resin affects both the yield and quality of the HFA. If channeling exists, then neither pretreatment (i.e. acidification) or adsorption of HFA will be complete, and the separation will lead to inaccurate results. If channels or spaces in the resin are observed prior to sample loading the column should be removed and shaken to redistribute the resin beads, by allowing them to settle without channels, and then re-packed by pumping clean DI H2O through the resin. In addition, as mentioned in the protocol, maintaining a volume of liquid above the resin when loading the FF onto the resin, will allow the FF to mix prior to entering the resin and result in more effective adsorption. For the strong cation H+-exchange resin (Table of Materials), complete regeneration cannot be rushed. The Na+/H+ exchange takes time and therefore this is best done in a bulk treatment so that the resin can be mixed while being re-acidified. Mixing the resin while rinsing with DI H2O helps remove the excess HCl. When rising the acidified resin to remove excess acid, mixing the resin help removing the HCl. It is extremely important to remove the acid to the point where an electrical conductivity of ≤ 0.7 µS/cm is reached. If not, the HCl will be carried over with the HFA.
Finally, when desorbing the HFA from the DAX-8 resin, once the absorbance of the influent equals the absorbance of the effluent, it is a good practice to let the column sit for a couple hours to see if any additional HFA will be released. If so, it will be seen as a yellowing of the liquid above the resin. If this occurs, the additional HFA can be removed by continued desorption until influent/effluent absorbances are equal again.
One of the disadvantages of the HFA isolation is that the entire process is time consuming. The complete desorption of HFA from the DAX-8 resin and complete removal from the H+-exchange resin both result in a significant volume of HFA that has to be reduced by rotary evaporation. This is definitely a bottleneck in the analysis. In an effort to reduce this time, desorbing the HFA from the DAX-8 resin using acetone rather than 0.1 M NaOH has been suggested14. The authors claimed that by using 50% acetone as desorbent in place of NaOH, a similar HFA result was obtained and the DAX-8 was adequately regenerated and thus the H+-exchange step could be eliminated. This modification resulted in a greatly reduced analysis time as a result of decreased volume produced and quicker rotary evaporation of acetone compared to water. This modification deservers further study.
This method is limited to the analysis of organic matter that has undergone the process of humification, and for the case of peat and soft coals, the further processes of peatification and both peatification and coalification, respectively. Humification is the process whereby dead, primarily plant material, is decomposed by a sequence of microbes that consume and modify increasingly recalcitrant substrates. Abiotic processes also participate in decomposition and re-synthesis reactions. Humification ultimately results in the production of relatively recalcitrant materials comprising heterogeneous mixtures of thousands of molecules that form a range of molecular weight and carbon, oxygen and hydrogen contents that form HS. HS are further modified by peatification and coalification. Therefore, this method is not appropriate for plants materials that have been modified by chemical processes. For example, lignosulfonate is widely used as an HFA adulterant. Lignosulfonate is a by-product of the sulfite pulping process. Therefore, this material has not been produced by the process of humification. In addition, there are many substances that bind to the DAX-8 resin. For example, DAX-8 resin has been used to adsorb pesticides from solution15. Obviously, pesticides are not HS. Thus, binding of a material to DAX-8 resin does not justify a claim that it is an HFA. The prerequisites are both production by humification and binding to DAX-8 resin.
As more is learned about the contribution of the various components of HS in different applications, it may become advantageous to further fractionate HS and thus modify the method accordingly. As it exists, the method does not quantify the HYFA. However, this fraction might also have activity e.g. in plant biostimulation, where the whole FF is generally applied in agricultural treatments rather than purified HFA.