The first step to identifying effective cancer treatments is the selection of a robust, unbiased cytotoxicity assay that can be used to examine the effect of treatment. A common choice for low-throughput experiments is the exclusion of trypan blue dye from living cells. This method is favored because it allows a relatively unbiased method for quantifying cell survival. trypan blue passively diffuses into cells whose membranes are compromised, but it is effectively blocked from entering healthy cells1. The quotient of the living cells and the total cells represents the percent viability, which indicates the efficacy of the treatment. The most significant disadvantage of the trypan blue assay is that it is poorly suited for high-throughput methodologies. It has a relatively low signal-to-noise ratio and prolonged staining can result in artifacts due to the staining of viable cells. Consequently, trypan blue exclusion is typically, but not always2, relegated to manual counting. This makes it too slow and introduces the strong possibility of bias due to subjective judgment of the researcher (unless blinding or independent counts are used, which further reduce laboratory throughput). In general, the throughput of this assay is insufficient for modern drug discovery.
Viability assays, which generally have a much higher throughput, allow researchers to circumvent this limitation, but come with significant caveats (see Table 1). These methods generally fall into two groups. One group is comprised of colorimetric assays that are based on the function of cellular redox enzymes. Colorless or non-fluorescent substrates are converted into vibrant products that can be quantified using a spectrophotometer. Classic examples include tetrazolium salts (MTT, WST-1, XTT, etc.) and resazurin. This category also includes luminescent assays that utilize luciferin to evaluate ATP level. Assays of this type have the underlying limitation that they are measuring cellular metabolism, which is not cellular viability per se. It is quite common for cells to become quiescent under adverse conditions, but still retain the ability to divide3,4,5. For example, cancer stem cells are often relatively metabolically quiescent6,7,8,9, and are likely to be difficult to assay using these techniques. Effectiveness of treatments that damage mitochondrial function, such as most mitocans, is also likely to be significantly overestimated.
An alternative methodology leverages the chemical properties of various substances that allow them to either cross or not cross biological membranes. One example are nuclear stains such as SYTOX or propidium iodide (PI). This category also includes assays that are similar in concept but different in function, such as the lactate dehydrogenase (LDH) assay, which measures the release of LDH into the extracellular milieu as an indicator of cellular necrosis (Figure 1, Table 1). These assays are more capable of distinguishing between metabolically inactive and dead cells.
| Assay/dye | Type(s) of cell death detected | Necessary equipment | Key features |
| MTT, CKK-8, Alamar Blue (resazurin) | Apoptosis/Necrosis | Spectrophotometer | Inexpensive, rapid; endpoint assay; dependent on enzymes' activity (exclusively mitochondrial in case of MTT) and does not discriminate between modes of cell death1,10 |
| LDH release | Necrosis | Spectrophotometer | Rapid, independent of mitochondrial enzymes’ activity; expensive for high-throughput tests; detects necrotic cells with compromized plasma membrane11,12 |
| Trypan Blue (TB) | Apoptosis/Necrosis | Microscope | Cell-impermeant; does not discriminate between modes of cell death; laborous and not suitable for high-throughput screening; more difficult to use with adherent cells; prone to subjective judgment of the user, but is considered the standard cell viability measurement method13 |
| Acridine orange (AO) | Apoptosis/Necrosis/ | Fluorescence microscope | A nucleic acid dye with unique spectral properties, can distinguish between apoptosis and necrosis/necroptosis14 |
| Necroptosis |
| Hoechst 33342, DAPI | Apoptosis | Fluorescence microscope or flow cytometer | Cell-permeable; inappropriate on its own to monitor cell death; useful for co-staining; can be used to assess chromatin condensation and nuclei fragmentation in early apoptosis; can be paired with propidium iodide to distinguish apoptosis from necrosis15,16 |
| Propidium Iodide (PI) | Late apoptosis/Necrosis | Fluorescence microscope or flow cytometer | Cell-impermeant intercalator; detects both late apoptosis and necrosis modes of cell death17. Toxic and permeable after long incubation times18 |
Table 1. List of cytotoxicity assays. Cytotoxicity assays, some of which were used in this study, listed along with the brief description of their key features.
Recent studies have demonstrated that mitochondrial metabolism is altered in some cancers19,20,21,22,23,24,25. For example, acute myeloid leukemias (AML) have been shown to upregulate their mitochondrial mass, mtDNA content, and mitochondrial respiration to meet their energy demands19,26,27. On the other hand, some solid tumors are characterized by mitochondrial dysfunction, or rather “metabolic reprogramming”, such as downregulation of mitochondrial proteins involved in OXPHOS or decreased mtDNA content, that has been associated with tumor invasiveness, metastatic potential and resistance to apoptosis-inducing drugs28,29. Furthermore, recently, there has been an increased interest in using mechanistically diverse compounds that affect mitochondrial function (generally called mitocans30), as potential therapies for particular cancers. These drugs target ATP synthesis, mitochondrial DNA, OXPHOS, and ROS production, as well as pro-apoptotic and anti-apoptotic proteins associated with mitochondria30,31. Several studies have shown that this approach has significant promise19,32,33,34. However, these metabolic deviations in cancer cell biology or mitochondria-targeting treatments may significantly affect conventional viability assays that are based on mitochondrial functionality.
Here, an optimized protocol for a differential nuclear staining assay is described. The protocol allows fast and accurate determination of cytotoxicity of mitocans or their combinations with other compounds. Hoechst 33342 is a cell-permeant nuclear dye that readily crosses cell membranes to stain DNA, allowing the total cell count to be obtained. By co-staining with PI, which only enters the nuclei of dead cells, the proportion of living (Hoechst only) and dead (stained with both) cells can be accurately determined. This protocol refines the published assay35 by adding a step for the optimization of the dye concentration (by cross-referencing results with orthogonal trypan blue method) and centrifugation of the plate prior to imaging. Since many cell lines are semi-adherent or suspended, centrifugation increases the proportion of cells that are imaged and strongly improves accuracy. The assay has several advantages, including that staining does not require removal of media or washing. The dye mixture is also inexpensive, easy to prepare, and compatible with multichannel/robotic pipetting systems.
After cells have been stained, they are imaged with an automated microscope. This has the added advantage of creating a permanent record of the images that can be re-analyzed later and the effects of particular compounds can be re-evaluated by visual inspection of captured images. Once images have been obtained, cells can be counted either manually or by using any of several software packages, including both free (e.g., ImageJ, CellProfiler, etc) and commercial software (e.g., Metamorph, Gen5, etc). Automated cell counting is generally preferable since properly developed automated cell counting pipelines are more accurate and less biased than manual counts. They also more effectively disregard cell debris or insoluble complexes. Development of these pipelines is generally straightforward and is simplified by the efficiency of the stains used. The output is quantitative since the actual number of dead cells is automatically calculated with respect to total cell number, and different thresholds can be applied to increase or decrease the stringency of detection35. For convenience, optimized parameters for counting cells using Gen5 v. 3.00 software compatible Cytation 5 Cell Imaging Multi-Mode Reader are included.