The electrocardiogram (ECG), a test that measures the electrical activity of one’s heartbeat, is a valuable tool for evaluating the cardiac conduction system. The parameters that are measured by an ECG include heart rate, PR interval, QRS duration, and QT interval. In brief, PR interval corresponds to the time that is required for an electrical impulse to travel from the atrial sinus node through the atrioventricular node to the Purkinje fibers; QRS duration is the time for ventricular depolarization to occur through the Purkinje system and ventricular myocardium; and QT interval is the duration of ventricular repolarization.
ECG recordings in mice have helped researchers examine cardiac function and determine the physiological and pathophysiological mechanisms of cardiac phenotypes, such as arrhythmia, atrial fibrillation, and heart failure. Most cardiovascular research has involved studies in genetically engineered mouse models. It is often challenging to obtain meaningful data on ECG recordings from small mice that have been genetically manipulated.
There are several methods for performing ECGs in mice1. Studies suggest that ECG recordings in conscious animals are preferred over anesthetized animals when possible since the effects of anesthesia on cardiac function have been well established2. Two protocols that record ECG in conscious mice are of note1. The ECG radiotelemetry system is the gold standard for continuous long term monitoring of ECG in conscious mice1,3. Despite their strength in being recorded in a conscious state, radiotelemetry-coupled ECG measurements have several limitations, including the high expense for setup and for the implant, its requirement of a highly experienced operator, a stabilization period of over 1 week, its need for large mice (> 20 g), and acquisition of only a single lead of ECG recording1. Another system that uses paw-sized conductive electrodes embedded in a platform allows ECG recordings in conscious mice without anesthesia or implants1,4. This non-invasive system is an alternative method in situations in which radiotelemetry systems are unavailable since it has many advantages: no requirement of surgical treatment, no need of anesthesia, low cost per mouse (only the initial setup is expensive), short time for measurement, and affordability of neonates1,4. The main disadvantage of this system is that it is not suited for continuous long term monitoring1.
Here we introduce another inexpensive, simple, and fast ECG recording method in anesthetized mice and demonstrate its validity and sensitivity by performing an ECG after autonomic blockade/stimulation of the cardiac conduction system. We suggest this ECG method for screening the effects of pharmacological agents, genetic modifications, and disease models in mice.