$$\rightleftharpoonup{xx}$$
$$\longleftharp{xx}$$,
$$\longrightharp{xx}$$,
Cardiac arrhythmias are common, affecting millions of patients worldwide1. Ageing populations show a growing incidence and thus a major public health burden resulting from cardiac arrhythmias and their morbidity and mortality2. Current treatment strategies are limited and often associated with significant side effects and remain ineffective in many patients3,4,5,6. Novel and innovative therapeutic strategies that causally target arrhythmia mechanisms are urgently needed. To study the complex pathophysiology of arrhythmias, suitable animal models are necessary; mice have been proven to be an ideal model species to evaluate the genetic impact on arrhythmias, to investigate fundamental molecular and cellular mechanisms, and to identify potential therapeutic targets7,8,9. Continuous ECG recording is a well-established concept in the clinical routine of arrhythmia detection10.
Implantable telemetry devices are among the most powerful tools available to study electrophysiology in mice as they allow continuous recording of the ECG (a common approach is to implant the leads in a lead-II position) over a period of several months in freely moving, awake mice11,12. However, due to the huge number of data points (up to more than 1 million QRS complexes per day) and limited knowledge of murine standard values, the analysis of telemetry data remains challenging. Commonly available telemetry transmitters for mice last up to 3 months, leading to the recording of up to 100 million QRS complexes. This means that pragmatic analysis protocols are much needed to reduce the time spent with each individual dataset and will allow researchers to handle and interpret this huge amount of data. To obtain a clean ECG signal upon recording, transmitter implantation needs to be optimal-the lead positions should be as far apart as possible to allow higher signal amplitudes.
The interested reader may be referred to a protocol by McCauley et al.12 for more information. Further, to minimize noise, cages and transmitters must be placed in a silent environment not prone to any disturbance, such as a ventilated cabinet with controlled environmental factors (temperature, light, and humidity). During the experimental period, lead positioning must be checked regularly to avoid loss of signal due to lead perforation or wound healing issues. Physiologically, there is a circadian alteration in ECG parameters in rodents as in humans, generating the need for a standardized approach to obtaining baseline ECG parameters from a continuous recording. Rather than calculating mean values of ECG parameters over a long period, analysis of a resting ECG similar to that in humans should be performed to obtain basic parameters such as resting heart rate, P wave duration, PR interval, QRS duration, or QT/QTc interval. In humans, a resting ECG is recorded over 10 s, at a normal heart rate of 50-100/min. This ECG includes 8 to 17 QRS complexes. An analysis of 20 consecutive QRS complexes is recommended in the mouse as "resting ECG equivalent". Because of the above-mentioned circadian alteration, a simple approach is to analyze two resting ECGs per day, one at daytime and one at night time. Depending on the light on/off cycle in the animal facility, suitable times are selected (e.g., 12 AM/PM), and basic parameters are obtained.
Next, a heart rate plot over time is used to detect relevant tachy- and bradycardia, with consecutive manual exploration of these episodes to get a first impression. This heart rate plot then leads to the important parameters of maximum and minimum heart rate over the recorded period as well as heart rate variability over time. After that, the dataset is analyzed for arrhythmias. This article describes a step-by-step approach to obtain these baseline ECG data from long-term telemetry recordings of awake mice over a recording period of up to three months. Further, it describes how to detect arrhythmias using the software, Ponemah version 6.42, with its analysis modules, ECG Pro and Data Insights, developed by Data Sciences International (DSI). This version is compatible with both Windows 7 (SP1, 64 bit) and Windows 10 (64 bit).