Microengineering 3D Collagen Hydrogels with Long-Range Fiber Alignment

Published: September 7, 2022 doi: 10.3791/64457

Summary

This protocol demonstrates the use of a microfluidic channel with changing geometry along the fluid flow direction to generate extensional strain (stretching) to align fibers in a 3D collagen hydrogel (<250 µm in thickness). The resulting alignment extends across several millimeters and is influenced by the extensional strain rate.

Abstract

Aligned collagen I (COL1) fibers guide tumor cell motility, influence endothelial cell morphology, control stem cell differentiation, and are a hallmark of cardiac and musculoskeletal tissues. To study cell response to aligned microenvironments in vitro, several protocols have been developed to generate COL1 matrices with defined fiber alignment, including magnetic, mechanical, cell-based, and microfluidic methods. Of these, microfluidic approaches offer advanced capabilities such as accurate control over fluid flows and the cellular microenvironment. However, the microfluidic approaches to generate aligned COL1 matrices for advanced in vitro culture platforms have been limited to thin "mats" (<40 µm in thickness) of COL1 fibers that extend over distances less than 500 µm and are not conducive to 3D cell culture applications. Here, we present a protocol to fabricate 3D COL1 matrices (130-250 µm in thickness) with millimeter-scale regions of defined fiber alignment in a microfluidic device. This platform provides advanced cell culture capabilities to model structured tissue microenvironments by providing direct access to the micro-engineered matrix for cell culture.

Introduction

Cells reside in a complex 3D fibrous network called the extracellular matrix (ECM), the bulk of which is composed of the structural protein collagen type I (COL1)1,2. The biophysical properties of the ECM provide guidance cues to cells, and in response, cells remodel the ECM microarchitecture3,4,5. These reciprocal cell-matrix interactions can give rise to aligned COL1 fiber domains6 that promote angiogenesis and cell invasion in the tumor environment7,8,9 and influence cell morphology10,11,12, polarization13, and differentiation14. Aligned collagen fibers also promote wound healing15, play a key role in tissue development16, and contribute to long-range cell communication17,18. Therefore, replicating the native COL1 fiber microarchitecture in vitro is an important step toward developing structured models to study cell responses to aligned microenvironments.

Microfluidic cell culture systems have been established as a preferred technology to develop microphysiological systems (MPS)19,20,21,22,23. Leveraging favorable microscale scaling effects, these systems provide precise control over fluid flows, support the controlled introduction of mechanical forces, and define the biochemical microenvironment within a microchannel21,24,25,26,27. MPS platforms have been used to model tissue-specific microenvironments and study multi-organ interactions28. Simultaneously, hydrogels have been widely explored to recapitulate the 3D mechanics and biological influence of the ECM that are observed in vivo29,30. With a growing emphasis on integrating 3D culture with microfluidic platforms, numerous approaches can combine COL1 hydrogels in microfluidic devices31,32,33. However, the methods to align COL1 hydrogels in microfluidic channels have been limited to thin 2D "mats" (<40 µm in thickness) in channels <1 mm wide, offering limited potential to model cell responses in aligned 3D microenvironments31,34,35,36.

To achieve aligned 3D COL1 hydrogels in a microfluidic system, it has been shown that, when a self-assembling COL1 solution is exposed to local extensional flows (velocity change along the streamwise direction), the resulting COL1 hydrogels display a degree of fiber alignment that is directly proportional to the magnitude of the extensional strain rate they experience37,38. The microchannel design in this protocol is unique in two ways; first, the segmented design introduces local extensional strain to the COL1 solution, and second, its "two-piece" construction allows the user to align COL1 fibers and then disassemble the channel to directly access the aligned fibers in an open format. This approach can further be adopted to develop modular microfluidic platforms that develop microphysiological systems with ordered COL1 matrices. The following protocol describes the process of fabricating segmented microchannels and details the use of the channels to align bovine atelo COL1. This protocol also provides instructions for culturing cells on COL1 in an open well format and discusses adding functionality to the platform using a modular, magnetic base layer.

Subscription Required. Please recommend JoVE to your librarian.

Protocol

1. Fabrication of the two-piece channel and modular platform base

NOTE: The microfluidic channel is constructed using two parts — the microfluidic channel "cutout", which is razor cut from a poly dimethyl siloxane (PDMS) sheet of defined thickness, and the channel cover, which reversibly bonds to the cutout and forms the channel. The channel is surrounded by a poly(methyl methacrylate) (PMMA) frame that will acts as a media reservoir (Figure 1). The PMMA frame can also be used to magnetically latch specialized modules for added functionality.

  1. Razor cutting channels from PDMS sheets:
    NOTE: The microfluidic channel design for this step is provided in Supplementary Figure 1. The channel consists of five segments of length 5 mm each and widths of 10 mm, 5 mm, 2.5 mm, 1.25 mm, and 0.75 mm. The velocity of the collagen solution, injected at a constant flow rate (50-400 µL·min−1), increases locally along the channel as the channel width is decreased to generate extensional flow.
    1. Mount a 250 µm thick PDMS sheet onto a plastic carrier sheet and razor-cut the microfluidic design using a craft cutter at a blade depth of 0.5 mm, 1 cm·s−1 speed, and high force.
    2. Using an ultrasonic bath, clean the microfluidic channel cutouts for 5 min. Rinse the sonicated channels in deionized (DI) water and dry them on a clean hotplate at 100 ˚C for 5 min.
    3. Store the channels in a clean, covered Petri dish until use.
  2. Fabricating the PDMS cover and surface passivation:
    NOTE: The channel cutout from section 1.1 requires a cover that can be placed on top of it to create an enclosed channel that a COL1 solution can be injected into (Supplementary Figure 1). The cover can be removed after the COL1 has self-assembled. To minimize the chances of the COL1 in the channel binding to the cover, the cover is passivated using bovine serum albumin (BSA). The mold design for the PDMS cover is provided. The mold must be at least 2 mm in thickness and should have a footprint that is equal to the footprint of the microfluidic channel cutout. In this protocol, the mold footprint was 35 mm x 15 mm.
    1. To prepare the mold, affix a sheet of pressure-sensitive adhesive (PSA) to a 2.5 mm thick sheet of PMMA and laser cut the desired mold shape.
    2. Clean the laser-cut PMMA mold with a damp, lint-free wipe and remove the backing from the PSA film. Attach the mold to a 100 mm diameter silicon wafer bt pressing down firmly.
    3. Prepare PDMS in a ratio of 10:1 (base:crosslinker). Mix vigorously for 1 min to ensure proper mixing and degas the mixture in a vacuum chamber to remove air bubbles.
    4. Pour the degassed PDMS solution into the PMMA/silicon mold and cure on a hotplate at 100 ˚C for 20 min. Allow the mold to cool, remove the cured PDMS, and trim any excess with a razor blade.
      NOTE: Make sure the silicon wafer facing sides (flat sides) of the PDMS covers are facing up throughout all the following steps.
    5. Use a 1 mm diameter biopsy punch to create inlet and outlet holes that correspond to the ends of the microfluidic channel. The channel cutout from step 1.1 may be used as a template to guide the position of the holes.
    6. Sonicate the cover in isopropanol (IPA) for 5 min, rinse with DI water, dry with a compressed air source, and then store in a clean, covered Petri dish. Place the Petri dish in a UV sterilization chamber (uncovered) for 1 min to sterilize.
    7. Cover and transfer to a biosafety cabinet (BSC).
    8. Pipette 300 µL of 40 mg•mL-1 bovine serum albumin (BSA) in 1x phosphate buffered saline (PBS) onto the PDMS covers and spread the solution evenly using a pipette tip. Place in a refrigerator at 4 ˚C for at least 4 h before use.
    9. Move the covers from the refrigerator into a BSC, wash 5x with 1x PBS, and let them dry in air for 10 min.
      NOTE: The PDMS covers can be stored in the fridge for up to 1 week after coating them with BSA.
  3. Glutaraldehyde treatment of coverslips
    NOTE: Functionalizing the coverslips with glutaraldehyde covalently bonds COL1 to the coverslip and prevents the hydrogel from detaching.
    1. Prepare a 2% (v/v) aminopropyl triethoxysilane (APTES) solution in a glass beaker by adding 1 mL of APTES to 49 mL of acetone.
    2. Dilute a 25% glutaraldehyde solution to 5% in DI water. Make 2 mL of solution for each 24 mm x 50 mm coverslip. For 24 mm x 24 mm or 22 mm x 22 mm coverslips, make 1 mL of solution for each.
    3. Clean the coverslips in a bath sonicator for 5 min using IPA. Rinse off the IPA from the coverslips using DI water. The IPA is completely rinsed when a smooth film of water can be seen on the coverslip.
    4. Dry the coverslips on a hot plate for 5 min at 100 °C. Place the dried coverslips into clean Petri dishes, ensuring they do not overlap.
    5. Using a corona discharge wand, expose the coverslips to a corona discharge for 1 min each.
      NOTE: This step should be performed in a well-ventilated area or a chemical hood.
    6. Remove the coverslips from the Petri dish and then immerse into the APTES solution for 10 s within 5 min of corona exposure, ensuring the coverslip is submerged.
      NOTE: Make sure to keep track of which side was treated with plasma and keep it facing upward.
    7. Then, immerse the coverslip into acetone for 10 s and dry with compressed air. Place the dry coverslip back into the Petri dish, treated side facing up.
      NOTE: Repeat steps 1.3.5-1.3.7 for all the coverslips.
    8. Pipette 1 mL of glutaraldehyde solution onto the surface of each coverslip. Cover as much surface as possible without allowing the solution to spill over the edge of the coverslip. More glutaraldehyde solution can be added if necessary. Make sure not to scratch the surface with the pipette tip.
    9. Let the coverslips sit in contact with the solution for 30 min and then rinse with DI water for 20 s. Dry the coverslips using compressed air and place them back in the Petri dishes, plasma treated side up.
      NOTE: The coverslips can be stored for up to 1 week at room temperature (RT).
  4. Laser cutting the modular magnetic base
    NOTE: The design of the modular magnetic base is provided in Supplementary Figure 1. The modular base serves as a well to hold the media and can also be used to magnetically attach specialized modules, as described in previously published works22,37,38,39.
    1. Cut out the designs from the PMMA layer using appropriate laser settings such as the number of passes and power.
      NOTE: The laser settings should be adjusted such that the magnets can be press fitted in the PMMA layer. Each laser is different, and the cut parameters must be optimized experimentally. For a 45 W laser, 100% speed, 100% power, and 3 passes are recommended for cutting 2 mm through 2 mm thick PMMA.
    2. Wash the laser-cut part using soap and water to remove debris from the laser-cutting process.
      NOTE: Do not use solvents to clean the laser-cut parts. Solvents may result in the propagation of microcracks in the laser-cut edges.
  5. Assembling the platform
    1. Push magnets (3/16 in diameter, 1/16 in thick) by hand into the laser-cut base. A soft hammer or screw-driver end may be used to help push in the magnet. The thickness of the magnets must be less than the thickness of the PMMA base to ensure the magnets are flush with the surface of the base.
      NOTE: The magnets allow the user to add functionality to the platform by attaching additional modules.
    2. Peel off the backing from the PSA sheet and attach the base to a glutaraldehyde-treated coverslip with the functionalized side facing up.
    3. Gently place the PDMS channel cutout into the cavity defined by the frame. Press down with wide-tip tweezers to remove air bubbles and ensure conformal contact.
    4. Place the BSA-treated channel cover on top of the channel cutout, with the BSA side facing down. Ensure the fluid inlet and outlet ports are aligned with the channel.
    5. The device is ready for the COL1 injection.

2. Injecting the COL1 solution into the microchannel and removing the cover for cell culture applications

  1. Preparing the COL1 solution
    1. Place all the required reagents (COL1 stock solution [6 mg·mL−1], ultrapure water, 10x PBS, 0.1 M NaOH) on ice in the biosafety cabinet.
    2. Calculate the volume of reagents as follows
      Equation 1
      Equation 2
      Equation 3
      Equation 4
      NOTE: Therefore, to make 1 mL of 2.5 mg·mL−1 neutralized collagen from a 6 mg·mL−1 stock, add 416.67 µL of collagen, 429.16 µL of DI water, 100 µL of 10x PBS, and 54.16 µL of 0.1 M NaOH for a final pH of 7. Add 20 µL of 0.1 M NaOH to achieve a pH of 9.0.
    3. Add the reagents into an empty 5 mL vial in the following order: i) COL1 stock, ii) DI water, iii) 10x PBS, iv) 0.1 M NaOH.
      NOTE: Use a displacement pipette to handle the COL1 solution. Significant sample loss may occur if a regular pipette is used, leading to fluctuations in final solution concentration.
    4. Raise the pH of the solution to the desired pH (typically between 7-9).
  2. Injecting the COL1 solution
    1. Place a syringe pump, a chilled sterile syringe, chilled neutralized COL1 solution, and a sterile 20 G 90˚ angle tip Luer lock needle into a biosafety cabinet. Load the COL1 solution into the syringe, taking care to avoid introducing bubbles.
    2. Attach the 90˚ 20 G needle tip to the syringe, load the syringe into the syringe pump, needle facing down, and prime the needle with the COL1 solution.
    3. Set the syringe pump to the required flow rate, between 50-2,000 µL/min.
    4. Place prepared PDMS channels (section 1) on a lab jack and level with the needle.
    5. Insert the needle into the inlet port of the PDMS channel (wide side). Inject the channel until a ~30 µL drop of COL1 collects on the outlet side.
    6. Lower the lab jack and gently separate the needle from the newly filled channel.
    7. Repeat steps 2.2.5-2.2.9 until all channels have been filled with COL1 solution.
    8. Load the filled channels into the Petri dishes alongside a clean, lint-free wipe saturated with DI water to prevent dehydration of the newly formed COL1 gel.
    9. Cover the Petri dish and place the loaded channels in the incubator (37 ˚C, 95% humidity) for 2 h before the peel-off step.
  3. Peel off and media equilibration
    1. Expose the polymerized COL1 gel by lifting off the PDMS cover using tweezers. The BSA treatment prevents COL1 from attaching to the cover.
    2. Add 650 µL of EGM to the well.
    3. Leave the devices in the incubator (37 ˚C, 95% humidity) for a minimum of 4 h to equilibrate the gel and media. Replace the media before seeding with cells
  4. Seeding cells
    1. Place warm 0.25% trypsin and culture media along with the required number of 5 mL and 10 mL pipettes in the biosafety cabinet.
    2. Culture human umbilical vein endothelial cells (HUVECs) to 80% confluency in endothelial growth media (EGM) at 37 ˚C, in 95% humidity. Place the tissue culture flask containing HUVECs in the BSC after checking confluency under a microscope.
    3. Discard the media in the T25 flask and wash the cells 2x with 1x PBS. Add 1 mL of Trypsin to the flask and place it in the incubator (37 ˚C, 95% humidity) for 3 min.
    4. Check the flask under the microscope after 3 min to ensure that the cells are completely detached from the surface.
    5. Add 3 mL of EGM (with serum) to the flask to neutralize the trypsin. Next, transfer the cell solution using a 5 mL pipette into a 15 mL conical tube. Centrifuge the conical tube containing cells at 150 x g for 5 min.
    6. Place the conical tube in the biosafety cabinet and discard the supernatant without disturbing the cell pellet. Resuspend the cells in 1 mL of fresh culture media.
    7. Add and mix 15 µL of trypan blue and 15 µL of the resuspended cell solution in a 1 mL conical tube.
    8. Inject trypan blue and cell solution on both sides of a cell counting slide and insert the slide into a cell counting device.
    9. Dilute the cell solution in endothelial growth media to the required concentration based on the cell concentration obtained from the cell counting device.
      NOTE: A T25 flask of HUVECs at 80% confluency will yield ~750,000 cells·ml−1 if diluted in 1 mL of media. The volume of the cell suspension to be seeded is calculated as area of the culture surface × cell density/concentration of cell suspension. Example: To seed 20,000 cells·cm−2 in the 35 mm x 15 mm well, one will need ~140 µL of the cell suspension.
    10. Aspirate the media on the engineered COL1 matrix.
    11. Add the required volume of the cell solution onto the COL1 substrate and let the cells settle for a minimum of 4 h before imaging.
  5. Labeling the cell nucleus and cytoskeleton
    1. Aspirate the media from the cells and wash 3x with 1x PBS, 500 µL in each wash. Cover the cell layer with 4% paraformaldehyde for 15 min at RT.
    2. Aspirate the paraformaldehyde and wash with 1x PBS Tween-20 for 5 min.
    3. Permeabilize the cell membrane using 500 µL of 0.1% Triton-X solution in PBS for 15 min. Wash with 1x PBS Tween-20 for 5 min.
    4. Block the non-specific binding sites with 500 µL of 4% BSA in PBS for 30 min at RT.
    5. Dilute the phalloidin-actin fluorescent label solution in 4% BSA (1 µL of stock in 400 µL of BSA).
    6. Aspirate the BSA solution, add the phalloidin solution to the cells, and wait for 30 min at RT.
    7. Dilute the nuclear stain in 4% BSA (1 µL in 500 µL), aspirate the phalloidin, add the working nuclear stain solution, and wait for 15 min at RT.
    8. Aspirate the nuclear stain working solution, wash with PBS Tween-20 3x for 5 min each, and replace with 1x PBS before imaging.
    9. Image using an epifluorescent microscope using the FITC channel (ex 491 nm/em 516 nm) and DAPI channel (ex 360 nm/em 460 nm) with a 40x lens. Image the collagen using a laser scanning confocal in the reflectance mode using the 488 nm laser line (15% power) and 40x water-immersion objective.

Subscription Required. Please recommend JoVE to your librarian.

Representative Results

When a self-assembling COL1 solution flows through a channel with decreasing cross-sectional area, the streamwise velocity (vx) of the COL1 solution increases locally by a magnitude, ∂vx, along the length of the constriction between the two segments (∂x), resulting in an extensional strain rate (ε̇) where ε̇ = ∂vx/∂x. The extensional strain rate can be calculated from the fluid velocity, which is measured using particle image velocimetry (PIV), as seen in Figure 2.

Previously, it has been shown that local extensional strain promotes long-range COL1 fiber alignment37,38,40 (Figure 3). The alignment of COl1 is directly influenced by the magnitude of the extensional strain rate in the constriction and can be observed to extend uniformly throughout the 5mm length of the segment. To measure the fiber alignment, confocal reflectance microscopy (CRM) images of fibers were used to create a histogram of fiber alignment. The coefficient of alignment (CoA) is the fraction of fibers aligned within ±15˚ of the mode value in the histogram38,42,43,44. CoA ranges from 0-1 with values >0.5 were considered aligned.

Injecting a 3D hydrogel into traditional, sealed microchannels limits where media and cells can be introduced to the matrix. The two-piece channel in this protocol overcomes the limitation of accessing a hydrogel in a channel by allowing the user to lift off the channel cover and directly access the entire COL1 matrix. Channel lift-off is enabled by functionalizing the glass coverslip with glutaraldehyde to promote COL1 attachment using amine-aldehyde-amine interactions and functionalizing the PDMS cover with BSA to prevent COL1 adsorption on the cover. The COL1 fiber alignment remains unaffected after lifting off the cover, as seen visually in Figure 4.

Aligned COL1 substrates are known to influence cell alignment by directing protrusions9,12,45,46 and, in turn, the organization of stress filaments. Endothelial cells in the unaligned and aligned COL1 segments were imaged to investigate the cellular response to the COL1 matrices developed using this protocol. The cells were fixed and stained 4 h after seeding. Representative images of the HUVECs cultured on the aligned segment of the matrix showed increased actin fiber alignment compared to the HUVECs on the segment with random fibers (Figure 5).

Figure 1
Figure 1: Schematic showing the assembly of the layers. This figure was adapted with permission from Ahmed et al.38. Please click here to view a larger version of this figure.

Figure 2
Figure 2: Stepped channel and extensional strain rates. (A) Schematic of the stepped channel with dimensions. Outset shows the calculation of the extensional strain rate. The extensional strain rate in each constriction is calculated from the velocity measured using particle image velocimetry (PIV). (B) The extensional strain rates in each constriction. This figure was adapted with permission from Ahmed et al.38. Please click here to view a larger version of this figure.

Figure 3
Figure 3: Confocal reflectance images of COL1 fibers in each microchannel segment after COL1 polymerization. The increase in the degree of fiber alignment from segment (a) to segment (e) can be visually observed. Scale bar = 25 µm. This figure was adapted with permission from Ahmed et al.38. Please click here to view a larger version of this figure.

Figure 4
Figure 4: Confocal reflectance images of COL1 fibers showing that the fiber alignment remains unaffected by removing the channel cover. Scale bar = 25 µm. This figure was adapted with permission from Ahmed et al.38. Please click here to view a larger version of this figure.

Figure 5
Figure 5: Representative images of cells and COL1 fibers. Representative images of cells and COL1 fibers in segment (e) of the COL1 matrix and segment (a) of the COL1 matrix. Please click here to view a larger version of this figure.

Supplementary Figure 1: Figure showing laser-cut components with dimensions. (A) Channel, (B) magnetic base, and (C) channel cover mold. All dimensions in millimeters. Please click here to download this File.

Subscription Required. Please recommend JoVE to your librarian.

Discussion

Protocols to generate COL1 matrices with aligned fibers have been described using magnetic methods, the direct application of mechanical strain, and microfluidic techniques47. Microfluidic approaches are commonly used to create microphysiological systems because of their well-defined flow and transport characteristics, which enable precise control over the biochemical microenvironment. Since aligned COL1 fibers provide key instructive cues during pathophysiological processes such as wound healing, tumor cell invasion, and tissue development, generating aligned COL1 matrices in microfluidic systems is a step toward developing biologically relevant microphysiological systems.

This protocol provides the ability to fabricate millimeter-scale, aligned COL1 matrices with regions of defined fiber alignment. To induce alignment, a microfluidic channel with stepwise reductions in width is used. As a self-assembling COL1 solution flows through the channel at a constant flow rate, the solution flow velocity increases at the constrictions, resulting in local extensional strain and long-range alignment of the self-assembling COL1 fibers. Compared to shear flow-induced fiber alignment, we observed fiber alignment in channels up to 250 µm in thickness, allowing us to create 3D hydrogels in a microfluidic channel. Since COL1 fiber alignment relies upon the extensional strain rate, users may modify the provided channel or develop custom channel designs to generate extensional flow and create COL1 matrices of the desired size and shape. Additional flexibility is provided through the soft lithography-free fabrication of the channels, allowing for the rapid prototyping of channel designs.

The two-piece channel approach presented in this protocol overcomes the limitations of accessing a 3D hydrogel in microchannels. A two-piece channel provides direct access to the COL1 hydrogel, wherein the channel cover can be lifted off to reveal the COL1 matrix in the channel. Directly accessing the COL1 after polymerization eliminates the need for cells to be mixed into the COL1 precursor solution, allowing a user to manipulate the COL1 precursor solution for extended periods at non-physiological pH and low temperatures. Further, a modular approach can be used to position the cells and provide layer-by-layer biofabrication capabilities, as shown in our earlier work. Modules can be used to introduce membranes for co-culture, introduce continuous perfusion, and also create multi-layered ECM constructs22,38,39. Custom modules can also be fabricated depending on experimental needs. Coupled with magnetic latching, the modular approach is also well suited to experiments that require adding functionality with time.

There are some critical steps that need to be considered in this protocol. All components, including the channel cutout, cover, coverslips, and modular base, should be cleaned appropriately to ensure proper bonding and chemical functionalization. The collagen should be prepared on ice, and all the components must be kept cold to ensure consistency. Once prepared, the collagen solution should be used within 10 min of preparation. The final pH of the collagen solution must be measured using a pH probe to ensure consistency. A clean, moist wipe must be placed in the Petri dish with the collagen to ensure that the collagen does not dry out in the warm incubator.

Some modifications and troubleshooting of the protocol include the following. (i) If media leaks during cell culture, one should ensure that the PMMA frame and coverslips are attached without any gaps in the adhesive layer. (ii) If the magnets are not set flush in the base layer, they will prevent the coverslip from adhering to the base, resulting in gaps. (iii) The glutaraldehyde coating on the coverslip can also be of a lower concentration if needed (down to 0.1%). The optimal concentration of glutaraldehyde to prevent toxicity should be experimentally determined for each cell line to be used in the experiment since glutaraldehyde may present toxicity to cells. (iv) One may include additional materials such as hyaluronic acid, fibronectin, or fluorescent beads along with collagen to customize the matrix further. (v) If needed, the channel design can be modified to have longer or shorter segments to avoid boundary and edge effects48.

This protocol has the following limitations. Atelo bovine collagen is a soft material (G' <100 Pa) at 2.5 mg·mL−1. To increase the gel stiffness, researchers may use higher concentrations of collagen or introduce crosslinking agents. Although this protocol has only been validated for aligning collagen matrices up to 250 µm in thickness, thicker matrices can be developed by increasing the channel thickness and optimizing the flow rates to introduce adequate extensional strain rates.

It is anticipated that this protocol will be of use to researchers seeking to develop tissue-specific ordered microenvironments. It may also be used as a guide for creating modular fluidic platforms to establish microphysiological systems.

Subscription Required. Please recommend JoVE to your librarian.

Disclosures

All authors declare no competing interests.

Acknowledgments

This work was supported in part by the National Institute of Health under award number R21GM143658 and by the National Science Foundation under grant number 2150798. The content is solely the responsibility of the authors and does not necessarily represent the official views of the funding agencies.

Materials

Name Company Catalog Number Comments
(3-Aminopropyl)triethoxysilane, 99% (APTES) Sigma Aldrich 440140-100ML
20 Gauge IT Series Angled Dispensing Tip Jensen Global JG-20-1.0-90
3/16" dia. x 1/16" thick Nickel Plated Magnet KJ Magnetics D31
3M (TC) 12X12-6-467MP DigiKey 3M9726-ND
ACETONE ACS REAGENT ≥99.5% Signa Aldrich 179124-4L
BD-20AC LABORATORY CORONA TREATER Electro-Technic Products 12051A
Bovine Serum Albumin (BSA), Fraction V, 98%, Reagent Grade, Alfa Aesar VWR AAJ64100-09
Clear cast acrylic sheet McMaster-Carr 8560K181
Corning 100 mL Trypsin 10x, 2.5% Trypsin in HBSS [-] calcium, magnesium, phenol red, Porcine Parvovirus Tested VWR 45000-666
Countess II Automated Cell Counter Thermo Fisher Scientific AMQAX1000
CT-FIRE software LOCI - University of Wisconsin
EGM-2 Endothelial Cell Growth Medium-2 BulletKit, (CC-3156 & CC-4176), Lonza CC-3162, 500 mL Lonza CC-3162
Glutaraldehyde 50% in aqueous solution, Reagent Grade, Packaging=HDPE Bottle, Size=100 mL VWR VWRV0875-100ML
Graphtec CELITE-50 Graphtec CE LITE-50
HEPES (1 M) Thermo Fisher Scientific 15-630-080
High-Purity Silicone Rubber .010" Thick, 6" X 8" Sheet, 55A Durometer McMaster-Carr 87315K62
Human Umbilical Vein Endothelial cells Thermo Fisher Scientific C0035C
Invitrogen Trypan Blue Stain (0.4%) Thermo Fisher Scientific T10282
Isopropanol Fisher Scientific A4154
Laser cutter Full Spectrum 20x12 H-series
Microfluidics Syringe pump New Era Syringe Pumps NE-1002X
Microman E Single Channel Pipettor, Gilson, Model M1000E Gilson FD10006
Molecular Probes Alexa Fluor 488 Phalloidin Thermo Fisher Scientific A12379
Molecular Probes Hoechst 33342, Trihydrochloride, Trihydrate Thermo Fisher Scientific H3570
Nutragen Bovine Atelo Collagen Advanced BioMatrix 5010-50ML
Pbs (10x), pH 7.4 VWR 70011044.00
PBS pH 7.4 Thermo Fisher Scientific 10010049.00
Phosphate-buffered saline (PBS, 10x), with Triton X-100 Alfa Aesar J63521
Replacement carrier sheet for graphtec craft ROBO CC330L-20 USCUTTER GRPCARSHTN
Restek Norm-Ject Plastic Syringe 1 mL Luer Slip Restek 22766.00
Silicon wafer University wafer 452
Sodium Hydroxide, ACS, Packaging=Poly Bottle, Size=500 g VWR BDH9292-500G
Sylgard 184 VWR 102092-312
Thermo Scientific Pierce 20x PBS Tween 20 Thermo Fisher Scientific 28352.00

DOWNLOAD MATERIALS LIST

References

  1. Frantz, C., Stewart, K. M., Weaver, V. M. The extracellular matrix at a glance. Journal of Cell Science. 123 (24), 4195-4200 (2010).
  2. Bosman, F. T., Stamenkovic, I. Functional structure and composition of the extracellular matrix. The Journal of Pathology. 200 (4), 423-428 (2003).
  3. Cox, T. R., Erler, J. T. Remodeling and homeostasis of the extracellular matrix: Implications for fibrotic diseases and cancer. Disease Models & Mechanisms. 4 (2), 165-178 (2011).
  4. Cross, V. L., et al. Dense type I collagen matrices that support cellular remodeling and microfabrication for studies of tumor angiogenesis and vasculogenesis in vitro. Biomaterials. 31 (33), 8596-8607 (2010).
  5. Lu, P., Takai, K., Weaver, V. M., Werb, Z. Extracellular matrix degradation and remodeling in development and disease. Cold Spring Harbor Perspectives in Biology. 3 (12), 005058 (2011).
  6. Piotrowski-Daspit, A. S., Nerger, B. A., Wolf, A. E., Sundaresan, S., Nelson, C. M. Dynamics of tissue-induced alignment of fibrous extracellular matrix. Biophysical Journal. 113 (3), 702-713 (2017).
  7. Provenzano, P. P., et al. Collagen reorganization at the tumor-stromal interface facilitates local invasion. BMC Medicine. 4 (1), 38 (2006).
  8. Provenzano, P. P., et al. Collagen density promotes mammary tumor initiation and progression. BMC Medicine. 6 (1), 11 (2008).
  9. Szulczewski, J. M., et al. Directional cues in the tumor microenvironment due to cell contraction against aligned collagen fibers. Acta Biomaterialia. 129, 96-109 (2021).
  10. Aubin, H., et al. Directed 3D cell alignment and elongation in microengineered hydrogels. Biomaterials. 31 (27), 6941-6951 (2010).
  11. Gruschwitz, R., et al. Alignment and cell-matrix interactions of human corneal endothelial cells on nanostructured collagen type I matrices. Investigative Ophthalmology & Visual Science. 51 (12), 6303-6310 (2010).
  12. Wang, W. Y., et al. Extracellular matrix alignment dictates the organization of focal adhesions and directs uniaxial cell migration. APL Bioengineering. 2 (4), 046107 (2018).
  13. Wang, W. Y., Lin, D., Jarman, E. H., Polacheck, W. J., Baker, B. M. Functional angiogenesis requires microenvironmental cues balancing endothelial cell migration and proliferation. Lab on a Chip. 20 (6), 1153-1166 (2020).
  14. Lanfer, B. The growth and differentiation of mesenchymal stem and progenitor cells cultured on aligned collagen matrices. Biomaterials. 30 (30), 5950-5958 (2009).
  15. Brauer, E., et al. Collagen fibrils mechanically contribute to tissue contraction in an in vitro wound healing scenario. Advanced Science. 6 (9), 1801780 (2019).
  16. Ingber, D. E. From mechanobiology to developmentally inspired engineering. PhilosophicalTransactions of the Royal Society B: Biological Sciences. 373 (1759), 20170323 (2018).
  17. Wang, H., Abhilash, A. S., Chen, C. S., Wells, R. G., Shenoy, V. B. Long-range force transmission in fibrous matrices enabled by tension-driven alignment of fibers. Biophysical Journal. 107 (11), 2592-2603 (2014).
  18. Reinhart-King, C. A., Dembo, M., Hammer, D. A. Cell-cell mechanical communication through compliant substrates. Biophysical Journal. 95 (12), 6044-6051 (2008).
  19. Ahadian, S., et al. Organ-on-a-chip platforms: A convergence of advanced materials, cells, and microscale technologies. Advanced Healthcare Materials. 7 (2), 1700506 (2018).
  20. Hou, X., et al. Interplay between materials and microfluidics. Nature Reviews Materials. 2 (5), 17016 (2017).
  21. Abhyankar, V. V., et al. A platform for assessing chemotactic migration within a spatiotemporally defined 3D microenvironment. Lab on a Chip. 8 (9), 1507-1515 (2008).
  22. Abhyankar, V. V., Wu, M., Koh, C. Y., Hatch, A. V. A reversibly sealed, easy access, modular (SEAM) microfluidic architecture to establish in vitro tissue interfaces. PLoS One. 11 (5), 0156341 (2016).
  23. Williams, M. J., et al. A low-cost, rapidly integrated debubbler (RID) module for microfluidic cell culture applications. Micromachines. 10 (6), 360 (2019).
  24. Hsu, M. C., et al. A miniaturized 3D printed pressure regulator (µPR) for microfluidic cell culture applications. Scientific Reports. 12, 10769 (2022).
  25. Huh, D., Torisawa, Y. S., Hamilton, G. A., Kim, H. J., Ingber, D. E. Microengineered physiological biomimicry: organs-on-chips. Lab on a Chip. 12 (12), 2156-2164 (2012).
  26. Abhyankar, V. V., Lokuta, M. A., Huttenlocher, A., Beebe, D. J. Characterization of a membrane-based gradient generator for use in cell-signaling studies. Lab on a Chip. 6 (3), 389-393 (2006).
  27. Hasan, M. R., et al. One-step fabrication of flexible nanotextured PDMS as a substrate for selective cell capture. Biomedical Physics & Engineering Express. 4 (2), 025015 (2018).
  28. Meyvantsson, I., Beebe, D. J. Cell culture models in microfluidic systems. Annual Review of Physical Chemistry. 1, 423-449 (2008).
  29. Ma, Y., et al. Viscoelastic cell microenvironment: Hydrogel-based strategy for recapitulating dynamic ECM mechanics. Advanced Functional Materials. 31 (24), 2100848 (2021).
  30. Ma, Y., et al. 3D spatiotemporal mechanical microenvironment: A hydrogel-based platform for guiding stem cell fate. Advanced Materials. 30 (49), 1705911 (2018).
  31. Lee, P., Lin, R., Moon, J., Lee, L. P. Microfluidic alignment of collagen fibers for in vitro cell culture. Biomedical Microdevices. 8 (1), 35-41 (2006).
  32. Del Amo, C., Borau, C., Movilla, N., Asín, J., García-Aznar, J. M. Quantifying 3D chemotaxis in microfluidic-based chips with step gradients of collagen hydrogel concentrations. Integrative Biology. 9 (4), 339-349 (2017).
  33. Shi, N., et al. A 3D, magnetically actuated, aligned collagen fiber hydrogel platform recapitulates physical microenvironment of myoblasts for enhancing myogenesis. Small Methods. 5 (6), 2100276 (2021).
  34. Lanfer, B., et al. Aligned fibrillar collagen matrices obtained by shear flow deposition. Biomaterials. 29 (28), 3888-3895 (2008).
  35. Saeidi, N., Sander, E. A., Ruberti, J. W. Dynamic shear-influenced collagen self-assembly. Biomaterials. 30 (34), 6581-6592 (2009).
  36. Saeidi, N., Sander, E. A., Zareian, R., Ruberti, J. W. Production of highly aligned collagen lamellae by combining shear force and thin film confinement. Acta Biomaterialia. 7 (6), 2437-2447 (2011).
  37. Ahmed, A., et al. Microengineered 3D collagen gels with independently tunable fiber anisotropy and directionality. Advanced Materials Technologies. 6 (4), 2001186 (2021).
  38. Ahmed, A., et al. Local extensional flows promote long-range fiber alignment in 3D collagen hydrogels. Biofabrication. 14 (3), 035019 (2022).
  39. Mansouri, M., et al. The modular µSiM reconfigured: Integration of microfluidic capabilities to study in vitro barrier tissue models under flow. Advanced Healthcare Materials. , (2022).
  40. Paten, J. A., et al. Flow-induced crystallization of collagen: a potentially critical mechanism in early tissue formation. ACS Nano. 10 (5), 5027-5040 (2016).
  41. Liu, Y., Eliceiri, K. W. Quantifying fibrillar collagen organization with curvelet transform-based tools. Journal of Visualized Experiments. (165), e61931 (2020).
  42. Bredfeldt, J. S., et al. Automated quantification of aligned collagen for human breast carcinoma prognosis. Journal of Pathology Informatics. 5 (1), 28 (2014).
  43. Bredfeldt, J. S., et al. Computational segmentation of collagen fibers from second-harmonic generation images of breast cancer. Journal of Biomedical Optics. 19 (1), 016007 (2014).
  44. Carey, S. P., et al. Local extracellular matrix alignment directs cellular protrusion dynamics and migration through Rac1 and FAK. Integrative Biology. 8 (8), 821-835 (2016).
  45. Carey, S. P., Kraning-Rush, C. M., Williams, R. M., Reinhart-King, C. A. Biophysical control of invasive tumor cell behavior by extracellular matrix microarchitecture. Biomaterials. 33 (16), 4157-4165 (2012).
  46. Ahmed, A., et al. Engineering fiber anisotropy within natural collagen hydrogels. AmericanJournal of Physiology-Cell Physiology. 320 (6), 1112-1124 (2021).
  47. Mohammadi, H., Janmey, P. A., McCulloch, C. A. Lateral boundary mechanosensing by adherent cells in a collagen gel system. Biomaterials. 35 (4), 1138-1149 (2014).

Tags

Microengineering 3D Collagen Hydrogels Long-range Fiber Alignment Microfluidic Approach Cell Behavior Topographically Defined 3D Environments PDMS Sheet Microfluidic Design Ultrasonic Bath Deionized Water Hot Plate Petri Dish PDMS Cover Layer Functionalize Aminopropyl Triethoxysilane Solution Acetone Glutaraldehyde Solution Cover Slips
Microengineering 3D Collagen Hydrogels with Long-Range Fiber Alignment
Play Video
PDF DOI DOWNLOAD MATERIALS LIST

Cite this Article

Ahmed, A., Joshi, I. M., Goulet, M.More

Ahmed, A., Joshi, I. M., Goulet, M. R., Vidas, J. A., Byerley, A. M., Mansouri, M., Day, S. W., Abhyankar, V. V. Microengineering 3D Collagen Hydrogels with Long-Range Fiber Alignment. J. Vis. Exp. (187), e64457, doi:10.3791/64457 (2022).

Less
Copy Citation Download Citation Reprints and Permissions
View Video

Get cutting-edge science videos from JoVE sent straight to your inbox every month.

Waiting X
Simple Hit Counter