$$\rightleftharpoonup{xx}$$
$$\longleftharp{xx}$$,
$$\longrightharp{xx}$$,
Accurate and sensitive measurement of cAMP is crucial for understanding its role in various cellular processes and for studying the activity of cAMP-dependent signaling pathways. There are several methods commonly employed to measure cAMP levels, including ELISA, radioimmunoassay, FRET biosensors, and the GloSensor cAMP assay14,15,16,17,18. Each cAMP assay has strengths and weaknesses. The protocol allows the real-time detection and monitoring, ranging from minutes to hours, and measurement of cAMP dynamics within living cells without the need to include phosphodiesterase inhibitors. This latter point is critical for researchers interested in studying the role of phosphodiesterase isoforms in regulating cAMP signaling19. The biosensor is available commercially (see Table of Materials) in multiple versions: a green fluorophore that decreases fluorescence upon cAMP binding, a red fluorophore that exhibits increased fluorescence upon cAMP binding, and a green fluorophore that exhibits increased fluorescence upon cAMP binding. The downward version of the biosensor is most useful since the main limiting factor is the level of expression of the biosensor, and this version will display maximal fluorescence at baseline prior to starting an experiment, alleviating the need to assess biosensor expression by adding a maximal cAMP stimulus. The biosensor is also available in versions that are targeted to membrane microdomains, primary cilia, or to the nucleus. These different versions enable measurements of cAMP simultaneously in cytosolic and membrane/cilial compartments within the same cell. These novel tools are uniquely adept at the visualization and quantification of cAMP dynamics across different cellular components, a rapidly evolving and important area of study20.
The biosensors offer a straightforward method to effectively monitor real-time cAMP dynamics, enabling researchers to observe rapid changes in cAMP levels with exceptional temporal resolution. One of the key strengths of the biosensor lies in its high sensitivity, which allows for the detection of both subtle and significant variations in cAMP concentrations8. An example of this in the cAMP oscillations is observed at low levels of isoproterenol stimulus in HEK-293 cells with no phosphodiesterase inhibitor present (Figure 2B). This oscillatory behavior is not understood and appears unique to these cells, but the sensitivity and rapid kinetics of the biosensor enable their detection. It should be noted, however, that the biosensor can be readily saturated, so this biosensor can be limited in quantifying the differences between medium and large cAMP signals. This limiting feature is particularly relevant when employing phosphodiesterase inhibitors that cause global increases in cAMP levels when a receptor stimulus is also present. While we present the infection of HASM in this study, it's important to acknowledge the challenge associated with infecting primary cells using the BacMam vector. The Conditions should be optimized for individual cell types in order to achieve sufficient expression of the biosensor. Nonetheless, the sensitivity and scalability of the biosensor make it well-suited for high-throughput assays.
Another improvement of using this biosensor over FRET-based sensors is the minimization of photobleaching. Many fluorescent biosensors are subject to photobleaching following prolonged and repeated excitation. The protocols described here involve short-duration excitations that are spaced 30 s apart. The biosensor is also extremely bright, thus limiting potential photobleaching for this type of analysis. Photobleaching would be observed during the initial baseline read as a drift. If baseline drift were to occur, one could subtract the drifting baseline from the data before fitting the curve or increase the sampling interval to reduce the frequency of excitation.
Like other cAMP biosensors, this biosensor has high specificity for binding to cAMP. Consequently, the signals generated by this assay directly correlate to cAMP levels, significantly reducing the potential interference from other cellular components and providing reliable results. Furthermore, the versatility of the biosensor is worth highlighting. While the GloSensor assay is widely used in the field, it does have certain limitations. For instance, relying on transient transfection may result in inefficiencies in specific cell types, and the analysis of multiple parameters or processes within the same cell is a challenge. Additionally, the assay relies on luciferase enzymes that can be influenced by certain compounds, potentially leading to compromised result accuracy21. On the other hand, the biosensor, can be employed in various cell types and experimental systems, including adherent and suspension cells. Its compatibility with diverse cellular contexts allows researchers to investigate cAMP dynamics across different biological systems22,23,24. The integration of this biosensor assay with fluorescence microscopy enhances its utility even further since cell morphological information can also be gathered25,26,27.
This assay provides researchers with great flexibility in experimental design, enabling a wide range of investigations related to cAMP signaling. It serves multiple purposes, allowing for the measurement of basal cAMP levels, the study of cAMP fluctuations in response to diverse stimuli or treatments, and the exploration of cAMP dynamics in various physiological or pathological conditions. One of the key strengths of the assay is its compatibility with other techniques, which allows for a more comprehensive understanding of cAMP signaling. By combining the biosensor with methods such as immunofluorescence staining or genetic manipulation10, researchers can gain deeper insights into the precise spatial and temporal regulation of cAMP within specific cellular compartments or signaling pathways. Through this integration, researchers can investigate the diverse functions of cAMP in various contexts, leading to valuable insights into the complexities of cAMP-mediated cellular processes. Employing these techniques allows researchers to visualize and quantify cAMP levels at both the individual cell and population level, offering a comprehensive understanding of its distribution within the cell, including the identification of cAMP pools. As a result, the combination of these methods enables the acquisition of precise data, contributing significantly to our knowledge of cAMP signaling.
While traditional methods have been valuable for cAMP analysis, the introduction of cADDis represents a promising advancement in this field. Its specificity, sensitivity, and real-time capabilities make it a valuable addition to the researcher's toolkit, particularly due to its compatibility with living cells. With the ability to monitor cAMP levels in real-time and its high sensitivity, the biosensor offers a significant advantage in various experimental settings. This progress contributes to a deeper understanding of the dynamic nature of cAMP signaling and its functional implications in both physiological and pathological processes.