A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

The Application of Remote-Controlled High-Definition Capsule Endoscopy in Canine Bladder Examination

681 views

⸱

DOI:

10.3791/66990

⸱

May 30th, 2025

 ,  ,  ,  ,  , 

In This Article

Summary

Here, we present a protocol for examining the canine bladder using a high-definition capsule endoscope, surgically implanted and maneuvered to capture images of the bladder wall and urination dynamics. The procedure offers insights for developing precise urodynamic studies.

Abstract

This study investigated the feasibility and potential applications of capsule endoscopy for bladder examination using a canine model. Three adult male Beagle dogs underwent surgical implantation of capsule cystoscopes and were divided into three groups, each group with one Beagle: Group A (Beagle A) remained in a fixed supine position for 8 h, Group B (Beagle B) moved freely for 8 h, and Group C (Beagle C) had manually adjusted positions (prone, supine, squatting) for 20 min each. The implanted capsule endoscopes functioned successfully in all dogs. Group A primarily captured images of the bladder base (6 h 27 min). Group B acquired images of the bladder neck and base (7 h 12 min), including dynamic visualization of the bladder neck, prostatic fossa, and external urethral sphincter during natural urination. Group C yielded images of the bladder neck, base, and apex (56 min). The findings of this study demonstrate the ability of capsule endoscopy to provide dynamic, high-quality images of the canine bladder wall and suggest its potential for developing accurate and urodynamic assessments.

Introduction

Transurethral cystoscopy, a common diagnostic tool in urological surgery, is widely used clinically not only as a reliable method for diagnosing bladder cancer but also as an important means for treatment and postoperative follow-up1. However, traditional cystoscopic examination, whether rigid or flexible, often causes discomfort to patients and may lead to complications such as urethral damage and retrograde infection2. Additionally, traditional urodynamic tests, by disturbing the normal physiological activity of the urinary tract and the mental and psychological activities of patients, inevitably introduce certain erro....

Access restricted. Please log in or start a trial to view this content.

Protocol

This research was approved by the Medical Ethics Committee of the Affiliated Kunshan Hospital of Jiangsu University, strictly adhering to the Guidelines for the Ethics and Welfare of Experimental Animals. The ethical approval document number is 2021-06-008-K01.

1. Subjects

  1. Use three healthy adult male Beagles for the study. Randomly divide them into groups A, B, and C, with one dog per group.
  2. Inclusion criteria: Include animals that are 24 months old, approximately 12 kg in weight, and are free from cardiovascular, renal diseases, and other chronic conditions.
  3. Exclusion criteria: Exclude anim....

Access restricted. Please log in or start a trial to view this content.

Results

In this study, each Beagle (n = 3) received one capsule endoscope surgically implanted into its bladder, and all animals demonstrated normal post-operative recovery. The capsule endoscopes functioned properly and remained safely within the dogs, as confirmed by imaging studies (Figure 2). Under remote control, the devices captured clear images of all anatomical regions of the bladder at various stages, including the dome, posterior wall, anterior wall, neck, and both the right and left side .......

Access restricted. Please log in or start a trial to view this content.

Discussion

In recent years, with the advancement of endoscopic technology, both rigid and flexible cystoscopes have been widely applied in clinical practice. The conventional application of rigid cystoscopy is often cumbersome, with numerous blind spots and significant trauma. Patients experience high psychological stress during the procedure and may encounter discomfort or pain, as well as physiological responses such as increased heart rate, elevated blood pressure, and psychological stress reactions7. Fle.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have nothing to disclose.

Acknowledgements

Funding: This work was supported by the Kunshan Science and Technology Development Special Project (KS18062), the Jiangsu University Clinical Science and Technology Development Project (JLY20180110), and the First People's Hospital of Kunshan's Scientific Education and Health Promotion Project (CXTD21-D02).

AUTHOR CONTRIBUTION:
Yang Yuan conceived the study, conducted experiments, and drafted the manuscript. Leyi Liu analyzed the data. Dingli Hu and Shihao Zhang provided critical resources and helped with data interpretation. Bing Wang contributed to literature review and manuscript editing. Yunlong Li, as the....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
2-0 Silk sutureEthicon Inc. (Beijing)20193021851
20 G intravenous catheterShanghai Zhangdong Medical Technology Co., Ltd.383012
4-0 absorbable sutureEthicon Inc. (Beijing)20193021851
8 mm endotracheal tubeHenan Yadu Industrial Co., Ltd.Not applicable
AmpicillinChengdu Better Pharmaceutical Co., Ltd.H19993625
Animal anesthesia machineNanjing Suprex Medical Equipment Co., Ltd.Not applicable
Animal ECG monitorSmiths Medical (US)Not applicable
Animal laryngoscopeShanghai Maiben Medical Technology Co., Ltd.Not applicable
BeagleSchool of Agriculture and Biology, Shanghai Jiao Tong UniversityNot applicable
Gauze SpongesGauze Sponges13-761-52
IsofluraneAbbott Laboratories (Shanghai)H20059911
OMOM intelligent capsule endoscopeChongqing Jinshan Science & Technology (Group) Co., Ltd.NCG100
Povidone-iodine solutionChengdu Yongan Pharmaceutical Co., Ltd.H51022885
Propofol injectionXi'an Libang Pharmaceutical Co., Ltd.H19990281
Scalpel bladeShanghai Pudong Golden Ring Medical Supplies Co., Ltd.35Y1004
Sterile normal salineShijiazhuang No.4 Pharmaceutical FactoryH20066533
Surgical instrumentsJohnson & Johnson Medical (Shanghai)Not applicable
Dexmedetomidine hydrochlorideJiangsu Hengrui Medicine Co., Ltd.H20190407

References

  1. Matulewicz, R. S., Delancey, J. O., Meeks, J. J. Cystoscopy. JAMA. 317 (11), 1187(2017).
  2. Von Rundstedt, F. C., Lerner, S. P. New imaging techniques for nonmuscle invasive bladder cancer. Curr Opin Urol. 24 (5), 532-539 (2014).
  3. Chan, G., Qu, L. G., Gani, J.

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Canine ModelHigh-Definition ImagingRemote-Controlled EndoscopyCapsule CystoscopeUrodynamic AssessmentBladder Wall ImagingBladder Neck VisualizationProstatic Fossa

This article has been published

Video Coming Soon