This protocol presents an optimized rotator cuff repair technique that combines the medial knot-tying suture-bridge repair with a rip-stop configuration, designed to enhance cuff healing and minimize the risk of retear.
A subscription to JoVE is required to view this content. Sign in or start your free trial.
Method Article
This protocol presents an optimized rotator cuff repair technique that combines the medial knot-tying suture-bridge repair with a rip-stop configuration, designed to enhance cuff healing and minimize the risk of retear.
Rotator cuff tears remain one of the most common injuries encountered by shoulder surgeons. Although arthroscopic suture-bridge repair has demonstrated superior biomechanical properties and achieved promising clinical results, tendon retears remain a persistent challenge. To address this issue, we have introduced several refinements to optimize the existing repair techniques. One such refinement is the incorporation of a medial knot in the suture-bridge repair, which can decrease gap formation and enable a watertight repair, thereby improving tendon-bone healing. Another critical modification is the use of a rip-stop configuration in the medial row, which can reduce potential suture cut-out, strengthen the resistance of the suture-tendon interface, and lower the risk of type II retear. Therefore, we propose a novel hybrid repair technique that integrates medial knot-tying suture-bridge repair and rip-stop configuration into a single construct. Additionally, this new repair technique offers the benefit of reducing the number of suture passages and suture anchors required, thereby streamlining the repair process. In summary, this method represents a viable and effective alternative for the treatment of rotator cuff tears and may contribute to reducing the incidence of postoperative retears.
Rotator cuff tears remain the most common pathologies encountered by shoulder surgeons, with their prevalence increasing with age1,2,3,4. Arthroscopic suture-bridge repair has become a widely adopted technique for reattaching the torn cuff tendons to their anatomic footprints on the greater tuberosity of the proximal humerus5,6,7. This technique not only exhibits superior biomechanical properties, but also achieves higher healing rates compared to traditional single- and double-row repairs7,8,9,10,11,12.
Suture-bridge repair can be further categorized based on the presence of medial row knots. Previous studies have shown that the inclusion of medial knots significantly increases the footprint contact area and interface pressure, enhances load to failure strength, and provides greater stability and stiffness compared to knotless configurations13,14,15. Despite these advantages, retear remains a common complication, with the majority occurring at the medial site (type 2 retear) in medial knot-tying suture-bridge repairs5,7,16.
As the tendon-suture interface appears to be the weakest link in the repair construct, suture cut-out is believed to contribute significantly to type 2 retear17,18,19. Given the poor functional outcomes and the complexity of revision surgery associated with type 2 retear, there is a pressing need to optimize the current medial knot-tying suture-bridge repair5,20. The rip-stop configuration has demonstrated potential in mitigating suture cut-out, thereby improving the integrity of the suture-tendon interface21,22,23. In light of this, we propose a new surgical technique that incorporates the rip-stop configuration into the medial knot-tying suture-bridge repair. This technique is designed to improve tendon healing and reduce the risk of retear in patients with small to massive, retractable rotator cuff tears and compromised tendon quality.
Access restricted. Please log in or start a trial to view this content.
Informed consent was obtained from the patient for publication, and the surgical protocol was approved by the institutional review board at our hospital (No. K2022-077-00).
NOTE: The inclusion and exclusion criteria are as follows:
Inclusion criteria include: (i) symptomatic full-thickness rotator cuff tears. (ii) failed conservative treatment. (iii) double-row repair. (iv) complete repair.
Exclusion criteria include: (i) irreparable rotator cuff tears. (ii) partial-thickness rotator cuff tears. (iii) Goutallier grade > 3. (iv) Arthritic changes of the glenohumeral joint. (v) neurologic involvement.
1. Surgical procedure
2. Postoperative protocol
Access restricted. Please log in or start a trial to view this content.
A 65-year-old female patient with a medium-sized rotator cuff tear in her right shoulder underwent the arthroscopic rotator cuff repair using the described technique, performed by a senior shoulder surgeon with over 20 years' clinical experience. At the 1-year follow-up, her Visual Analogue Scale (VAS) pain score improved significantly from 6 preoperatively to 0. The American Shoulder and Elbow Surgeons score (ASES) increased markedly from 53.33 to 91.67. The patient achieved full restoration of shoulder range of motion,...
Access restricted. Please log in or start a trial to view this content.
In recent years, the development of various suture-bridge repair techniques has significantly advanced the treatment of rotator cuff tears5,6,7,11,12. Despite their clinical success, challenges persist in enhancing tendon-bone healing and reducing retear rates. A crucial factor for successful healing is achieving a watertight seal at the joint, which prevents ...
Access restricted. Please log in or start a trial to view this content.
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Special thanks are given to Hui Yu for the schematic illustrations.
Access restricted. Please log in or start a trial to view this content.
| Name | Company | Catalog Number | Comments |
|---|---|---|---|
| 4.5 mm HEALIX ADVANCE BR ANCHOR | Depuy Mitek | 222296 | Medial anchor |
| 4.75 mm HEALIX ADVANCE BR ANCHOR | Depuy Mitek | 222330 | Lateral anchor |
| Spectrum I Suture Hook, 45°Left Curve | Conmed | 97.14115 | |
| Spectrum I Suture Hook, 45°Right Curve | Conmed | 97.14215 | |
| Suture Retriever | Arthrex | AR-13971W |
Access restricted. Please log in or start a trial to view this content.