Simultaneous Plethysmography and Electromyography Recording in an ALS Mouse Model

0 views • 2:00 min • April 28th, 2025

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Begin with a mouse with amyotrophic lateral sclerosis or ALS, a motor neuron degenerative disease.

The mouse carries an implanted transmitter with electrode connections inserted into the scalene and trapezius muscles, which are involved in breathing.

Place this mouse in a plethysmography or a respiratory chamber positioned over a receiver and allow it to move freely.

In the chamber, the airflow is continuously monitored during the mouse's breathing while resting or moving and recorded as plethysmography signals.

Bring a magnet near the mouse to activate the transmitter, turning the receiver light on and confirming electrode activation.

These electrodes detect the electrical signals from the muscles and transmit these electromyography or EMG signals wirelessly to the recording device.

Compare the plethysmography and EMG signals from both muscles to analyze the muscle activity during breathing in resting and moving states in the ALS mouse.

Place the mouse in the plethysmography chamber for at least one hour to acclimate it prior to recording EMG and plethysmography. Prior to recording, but after calibration, turn on the transmitter by placing a strong magnet within one inch of the implanted animal. A red light on the front of the receiver will indicate when the transmitter is on.

Begin acquisition using the pull down menu labeled acquisition and choose Start Acquisition. Although the recording duration may vary by experiment, a typical plethysmography and EMG recording lasts one to three hours.

08:51

Measuring Respiratory Function in Mice Using Unrestrained Whole-body Plethysmography

Related Videos

0 Views

09:24

Repeated Measurement of Respiratory Muscle Activity and Ventilation in Mouse Models of Neuromuscular Disease

Related Videos

0 Views

06:35

In Vivo Electrophysiological Measurement of Compound Muscle Action Potential from the Forelimbs in Mouse Models of Motor Neuron Degeneration

Related Videos

0 Views

08:00

Ambulatory ECG Recording in Mice

Related Videos

0 Views

13:07

Simultaneous Intracellular Recording of a Lumbar Motoneuron and the Force Produced by its Motor Unit in the Adult Mouse In vivo

Related Videos

0 Views

03:26

Measuring Compound Muscle Action Potentials in Mouse Forelimb Muscles In Vivo

Related Videos

0 Views

12:39

High-density Electroencephalographic Acquisition in a Rodent Model Using Low-cost and Open-source Resources

Related Videos

0 Views

10:07

Simultaneous Recordings of Cortical Local Field Potentials, Electrocardiogram, Electromyogram, and Breathing Rhythm from a Freely Moving Rat

Related Videos

0 Views

11:54

Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy

Related Videos

0 Views

05:26

Low-Cost Electroencephalographic Recording System Combined with a Millimeter-Sized Coil to Transcranially Stimulate the Mouse Brain In Vivo

Related Videos

0 Views

Last updated: 27 June 2026