-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Behavior
P50 Sensory Gating in Infants
P50 Sensory Gating in Infants
JoVE Journal
Behavior
Author Produced
This content is Free Access.
JoVE Journal Behavior
P50 Sensory Gating in Infants

P50 Sensory Gating in Infants

Full Text
9,682 Views
12:55 min
December 26, 2013

DOI: 10.3791/50065-v

Anne Spencer Ross1,2, Sharon Kay Hunter1, Mark A Groth1, Randal Glenn Ross1

1Department of Psychiatry,University of Colorado School of Medicine, 2Colorado State University

Overview

This article describes methods for recording auditory P50 sensory gating, a physiological marker of cerebral inhibition that reflects early stages of attention in infants. The focus is on how this method can be applied to study attentional deficits associated with various psychiatric disorders.

Key Study Components

Area of Science

  • Neuroscience
  • Psychiatry
  • Developmental Psychology

Background

  • Attentional deficits are prevalent in psychiatric disorders like schizophrenia and ADHD.
  • These deficits often stem from neurodevelopmental issues that begin early in life.
  • P50 sensory gating is a method to measure attention in infants.
  • Understanding sensory gating can provide insights into early brain development and attention mechanisms.

Purpose of Study

  • To demonstrate the P50 sensory gating method in infants.
  • To explore the relationship between sensory gating and attentional deficits.
  • To provide a reliable technique for measuring attention in very young infants.

Methods Used

  • Electroencephalogram (EEG) recordings are taken from infants during sleep.
  • Auditory stimuli are presented to measure the P50 wave response.
  • Electrodes are placed on the scalp, and various signals are amplified and filtered.
  • Data analysis is performed using MATLAB software to assess sensory gating.

Main Results

  • Successful measurement of P50 sensory gating in infants during active sleep.
  • Demonstrated the importance of sleep conditions for accurate assessment.
  • Identified the relationship between sensory gating and attentional capabilities.
  • Provided a framework for future studies on infant attention and neurodevelopment.

Conclusions

  • P50 sensory gating is a valuable tool for studying attention in infants.
  • Understanding sensory gating can help in identifying early signs of attentional deficits.
  • The methods outlined can be adapted for various research settings focusing on infant development.

Frequently Asked Questions

What is P50 sensory gating?
P50 sensory gating is a physiological measure that reflects the brain's ability to filter out repetitive, non-informative sensory information.
Why is measuring attention in infants important?
Measuring attention in infants can help identify early neurodevelopmental issues that may lead to psychiatric disorders later in life.
How is the P50 wave measured?
The P50 wave is measured using EEG recordings while presenting auditory stimuli to the infant.
What conditions are necessary for accurate P50 measurements?
Infants should be in a state of active sleep to ensure accurate measurement of sensory gating.
What are the implications of poor sensory gating?
Poor sensory gating is associated with difficulties in attention and may indicate underlying neurodevelopmental issues.
How can researchers maximize the chances of infants staying asleep during the study?
Scheduling visits during the infant's regular nap time and creating a calm, dark environment can help keep infants asleep.

Methods to record auditory P50 sensory gating, a physiological marker of cerebral inhibition which reflects early stages of attention, are described.

Hi, I'm Ally Newton. I'm Dr.Sharon Hunter. I'm Dr.Randy Ross.

We're part of the Jerome Kern Labs and the developmental research program at the University of Colorado Denver School of Medicine. We're gonna be demonstrating infant P 50 gating a form of auditory sensory gating. Attentional deficits are common in a number of psychiatric disorders, including schizophrenia, bipolar mood disorder, autism, and attention deficit hyperactivity disorder, or A DHD.

There has been an increasing interest in the neurodevelopmental components of these attentional deficits. Neurodevelopmental meaning that while the deficits become clinically prominent in childhood or adulthood, the deficits are the results of problems in brain development that begin very early in life, in infancy or even prenatally. Despite this growing interest, there are a few methods for measuring intention and infancy, particularly methods that can be used in the first few days or weeks after birth.

P 50 sensory gating is one method that can be used in very young infants. Attention has several components. We'll concentrate here on one of the earliest components.

The brain is designed to filter out or gait repetitive non informative sensory information. The sensory gating can be measured using auditory evoke potentials. A novel auditory stimulus elicits a classic ELECTROENCEPHALOGRAPHIC or EEG record waves are designated as either positive P or negative N, and by the latency they occur after the stimulus for a typical adult response.

The early response components include N 40, P 50, and N 100 waves. Latencies in children are longer, but the waves are still termed N 40 P 50 and N 100 to maintain consistency with adult based literature. As soon as the second presentation of a stimulus, the brain inhibitory systems are active and the evoked response decreases.

We focus on the P 50 wave as occurring very early in sensory processing without conscious thought. We'll demonstrate later how to quantify this, but in general, a reduction in response to the second sound relative to the first is good sensory gating and an important first step in attention. Failure to inhibit response to the second sound represents poor sensory gating and is associated with difficulties and attention.

Because the participant is not asked to do anything, this task is ideally suited for use with young infants. There is one additional important issue. This automatic preattentive inhibitory process is ineffective during periods of heightened arousal.

Placing electrodes on a baby is enough to arouse and prevent accurate assessment of sensory gating. To counter this, babies need to be allowed to enter active sleep, the infant version of rapid eye movement or REM sleep prior to recording P 50. Sensory gating Silver, silver chloride electrodes filled with conductive pace are attached to the child with adhesive medical tape.

Electroencephalogram, EEG, and auditory evoke potentials are recorded from the vertex of the scalp at site zz. For aid in sleep staging, bipolar electrogram or EOG is recorded from electrodes directly superior and lateral to either the left or right eye. Submental, electromyogram or EMG is also recorded.

Signals are amplified 5, 000 times and filtered between 0.05 and a hundred hertz. EOG signals are amplified a thousand times and filtered between one and 200 hertz and EMG signals are amplified 10, 000 times and filtered between one and 2200 hertz. Sampling rate is set at a thousand hertz.

The data is converted to ACI format. Further analysis utilizes MATLAB software available from MathWorks and NA Massachusetts USA once the child is determined to be asleep and the electrode impedances are below 10 kilos paired clicks 50 milliseconds in duration and 500 milliseconds apart are presented through two speakers positioned on either side of the head. Inter stimulus interval between click pairs is consistent at 10 seconds.

Volume is adjusted so that each click yields an 85 decibel. Sound pressure level at the year recording is continued as long as the infant remains asleep, generally yielding between 30 and 90 minutes of continuous data. Sleep periods of greater than 60 minutes are generally necessary to identify sufficient periods of active sleep.

For analysis, The Best data is obtained while The baby is asleep. The goal is at least 15 minutes of uninterrupted active sleep. In order to obtain this amount, we generally record for an hour to an hour and a half.

There are many things that can be done to maximize the chances that the infant participant will stay asleep. This includes scheduling a visit at the infant's regular nap time, using a quiet room away from other activities, darkening the room, having a crib, baby swing and rocking chair available for whichever the baby prefers. A sheet is laid down for the baby's head at the head of the swing or Crip.

It is important to have everything ready before the baby arrives, including clean electrodes, conductive, EEG paste recording apparatus, such as a neuro scan made by com medics, neuro scan in Charlotte, North Carolina. Finally, and perhaps most importantly, you will need to schedule more time than you think you'll need. Babies are barometers for stress, and if the experimenter feels pressured, then the baby will feel stressed and not sleep as well.

When the baby arrives, be sure it is fed, burped, and it's diaper is clean before you start swaddle. If the baby prefers wipe the head with an electrode prep pad to minimize impedance, conductive, EEG paste and cloth tape are Used to hold the electrodes in place. An electrode is Placed on the forehead or behind the ears for the ground, which acts to reduce the impact of environmental noise.

An electrode is put on the right or left mastoid for a reference electrode. The reference can also be placed on the nose as long as it lies on the same line of the face as the mastoid. A tape measure is sometimes used to measure the halfway point on the head for the CZ electrode Placement.

An electrode is placed at cz. For the EEG Two are placed to record EOG or eye movements, one on the bone above the eyebrow and one on the Bone to the right of the eye, one is put on the chin for an EMG to measure muscle tone, we check impedance levels Using neuros scan. The reading should ideally be dark blue or black indicating low impedance.

Sometimes it's beneficial to wait for the pace to warm up on the baby's head, as that will create a lower impedance reading. It may also be necessary to press the electrodes down to try and get the desired impedance Levels. The room is normally darkened at this Time, but for filming purposes, we will keep it lit.

Comments about the process are recorded concurrently, such as if eyes are open or closed, any body movement, if the electrodes are moved or displaced by the baby's movement, or to get a better reading, any extraneous noise and possible times of active sleep. If heart rate is present in tracing, move the EMG electrode to a bony or part of the chin. If the reading is noisy or messy, it may be caused by electronic interference from something in the room such as a cell phone.

The electrode not seated securely, in which case the electrode can be pushed down to make more secure, or the wires are touching another electrical source, which can be avoided by taping the wires down. When the baby wakes up, an adhesive remover facilitates the removal of the tape and paste. Baby wipes are used to clean excess paste off the baby's head.

The family is then thanked and the recording moves to offline analysis. Here's a Portion of a tracing from a typical infant. The first step is to identify periods of active sleep and periods of quiet sleep.

In particular, we're looking for a period of active sleep lasting longer than 15 minutes. Active sleep will have large eye movements, active brain waves, which are characterized by their high frequency and low voltage, similar in appearance to when the child is awake. There will also be low muscle tone indicated by a flattened EMG and notes gathered during the recording will indicate the baby's eyes are closed and that the baby has irregular breathing.

After recording filters are applied to the tracings, including ones that remove waves that occur at about a frequency of 60 hertz. 60 hertz waves are generated by most US electronics. We also use a filter that takes out frequencies below one hertz and these are generated by just irrelevant drifts in the energy field.

This helps us distinguish brainwaves from those waves that are generated by the environment. Zooming in on a three second epic. You can see where the clicks occurred.

However, identifying specific evoked potential waves is difficult from a single two second epic. We thus the epics together, the more epics the clearer each component becomes. Here with 75 epics averaged together, you can see the waves we are interested in measuring.

The first large positive wave after the stimulus is presented is termed P one or P 50. It's followed by a second wave that is negative going called the N 100 Note. In babies, these occur later than seen than is seen in adults.

The P 50 for this baby actually occurred approximately 75 milliseconds after the stimulus versus the 50 milliseconds seen in adults. We measured the amplitude of the P 50 from the preceding trough to the peak after measuring response to the first and second sounds. The second amplitude is divided by the first.

To identify a gating ratio, the latency is measured at the highest point of the peak. Here's an example of a baby who has a ratio close to one that is who failed a gate and baby who has a ratio closer to zero, reflecting a well-functioning inhibitory process, which allows normal sensory gating. A distinct cutoff for what percentage is considered normal gating has not been established.

We use a 0.5 cutoff while keeping in mind that any percentage of gating is better than none. P 50 sensory gating is an effective method for measuring an early preattentive component of attention. The method is usable even in very young infants as young as a few hours old.

This method may provide insight into early development. It may also be useful as a mechanism to assess novel interventions aimed at preventing some attentional difficulties long before they become clinically relevant. We at the Jerome Kern Laboratories hoped his presentation was helpful at providing basic instruction for assessing P 50 sensory gating in young infants.

Explore More Videos

P50 Sensory GatingAttentional DeficitsNeurodevelopmental DisordersInfant Auditory P50 Sensory GatingSensory GatingEEGCerebral InhibitionAttentional Development

Related Videos

Electrophysiological Measurements and Analysis of Nociception in Human Infants

09:18

Electrophysiological Measurements and Analysis of Nociception in Human Infants

Related Videos

17.8K Views

Habituation and Prepulse Inhibition of Acoustic Startle in Rodents

08:38

Habituation and Prepulse Inhibition of Acoustic Startle in Rodents

Related Videos

76K Views

Quantitative Assessment of Cortical Auditory-tactile Processing in Children with Disabilities

09:38

Quantitative Assessment of Cortical Auditory-tactile Processing in Children with Disabilities

Related Videos

11.4K Views

Infant Auditory Processing and Event-related Brain Oscillations

06:34

Infant Auditory Processing and Event-related Brain Oscillations

Related Videos

17K Views

Behavioral Assessment of Hearing in 2 to 4 Year-old Children: A Two-interval, Observer-based Procedure Using Conditioned Play-based Responses

14:05

Behavioral Assessment of Hearing in 2 to 4 Year-old Children: A Two-interval, Observer-based Procedure Using Conditioned Play-based Responses

Related Videos

29.8K Views

Classical Short-Delay Eyeblink Conditioning in One-Year-Old Children

07:36

Classical Short-Delay Eyeblink Conditioning in One-Year-Old Children

Related Videos

40.5K Views

The Power of Interstimulus Interval for the Assessment of Temporal Processing in Rodents

10:27

The Power of Interstimulus Interval for the Assessment of Temporal Processing in Rodents

Related Videos

7.4K Views

Exploring Infant Sensitivity to Visual Language using Eye Tracking and the Preferential Looking Paradigm

06:07

Exploring Infant Sensitivity to Visual Language using Eye Tracking and the Preferential Looking Paradigm

Related Videos

9.2K Views

How to Obtain Reliable Visual Event-related Potentials in Newborns

07:39

How to Obtain Reliable Visual Event-related Potentials in Newborns

Related Videos

6.8K Views

Pupillometry to Assess Auditory Sensation in Guinea Pigs

09:25

Pupillometry to Assess Auditory Sensation in Guinea Pigs

Related Videos

2.4K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code