Confirmation of Myocardial Ischemia and Reperfusion Injury in Mice Using Surface Pad Electrocardiography

13.1K views

Cited by 11

09:23 min

November 24th, 2016

10.3791/54814-v

November 24th, 2016

13.1K views

During murine myocardial ischemia/reperfusion surgery, correct placement of the occluding ligature is typically confirmed by visible observation of myocardial pallor. Herein, a method of electrocardiographically confirming ischemia and reperfusion, to supplement observed myocardial pallor, is demonstrated in male C57Bl/6 mice.

Explore More Videos

Myocardial Ischemia Reperfusion

Chapters in this video

0:05

Title

0:39

Electrocardiogram (ECG) Acquisition

1:46

Surgical Procedure and ECG Recording

5:46

ECG Reperfusion Confirmation

7:02

Results: Typical ECG Changes Over the Course of an Ischemia/Reperfusion Surgery