-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Chemistry
Determining the Chemical Composition of Corrosion Inhibitor/Metal Interfaces with XPS: Minimizing...
Determining the Chemical Composition of Corrosion Inhibitor/Metal Interfaces with XPS: Minimizing...
JoVE Journal
Chemistry
This content is Free Access.
JoVE Journal Chemistry
Determining the Chemical Composition of Corrosion Inhibitor/Metal Interfaces with XPS: Minimizing Post Immersion Oxidation

Determining the Chemical Composition of Corrosion Inhibitor/Metal Interfaces with XPS: Minimizing Post Immersion Oxidation

Full Text
16,217 Views
07:44 min
March 15, 2017

DOI: 10.3791/55163-v

Monika S. Walczak1, Perla Morales-Gil1,2, Turia Belashehr1, Kiran Kousar1, Paulina Arellanes Lozada1,3, Robert Lindsay1

1Corrosion and Protection Centre, School of Materials,The University of Manchester, 2Laboratorio de Caracterización de Materiales Sintéticos y Naturales,Instituto Mexicano del Petróleo, 3Departamento de Metalurgia y Materiales,Instituto Politécnico Nacional

A protocol to avoid the oxidation of metallic substrates during sample transfer from an inhibited acidic solution to an X-ray photoelectron spectrometer is presented.

The overall goal of this experimental procedure is to prevent the oxidation of metallic substrates during sample transfer from an inhibited acidic solution to an x-ray photoelectron spectrometer. This procedure allows one to more reliably determine the chemical nature of corrosion inhibitor matter interfaces in acidic solutions, which is a key component of mechanistic understanding and performance prediction. A particular advantage of this approach is that it is relatively easy to apply.

And so, can be adopted by other researchers undertaking similar measurements. The protocol is relatively straightforward, but one should practice manipulating samples in the glove box as this is the most exacting segment of the method. Beyond corrosion inhibition, this approach should also be considered in other areas where XPS measurements are undertaken from air sensitive interfaces formed in a fluid environment.

We first decided to try this approach as we were concerned the previous work was compromised by oxidation of the inhibited interface upon exposure to air. To begin this procedure, prepare the carbon-steel substrate and the hydrochloric acid solution with added CI as outlined in the text protocol. Next, pour 25 milliliters of the prepared HCL plus CI solution into a small glass beaker.

Using acid resistant tweezers, pick up the disk shaped carbon-steel sample, then lower it into the HCL plus CI solution. Orient the sample so that the cylindrical faces are in the vertical plane. First, connect the glove box to a source of inert gas such as nitrogen or argon.

Then, adhere a small square of double sided conductive carbon tape onto the XPS sample bar. Insert all of the hardware required to transfer the sample to the XPS instrument into the glove box through an open port. After this, place the glass beaker containing the submerged substrate into the glove box.

Seal every port. Then, purge the glove box with inert gas. Allow the sample to remain submerged for the desired immersion period.

Monitor the relative humidity value within the glove box. Once the relative humidity is below eight percent, reach into the glove box gloves. Then, cover these with nitrile gloves.

Using tweezers, remove the carbon-steel sample from the solution. Immediately blow the sample dry using an empty wash bottle. Next, cover the beaker containing the HCL plus CI solution with a plastic paraffin film.

Affix the dried sample to the small square of tape on the XPS sample bar. After this, vent the XPS load lock chamber to the inert gas. Open the load lock flange, transfer the sample bar into the load lock chamber and slide it onto the sample holding prong.

Then, close the flange. Switch on the turbo rotary pump combination to pump down the chamber. Once the pressure reaches approximately five times 10 to the minus seven millibar, manually transfer the sample into the intermediate chamber using the transfer arm.

Using the keypad, orient the sample to the desired photoelectron emission angle. Next, open the XPS data acquisition software. Navigate to the instrument manual control window.

Input 10 milliamps and 15 killivolts as the values for the anode emission and anode HT parameters respectively. Then, click the On button in the Xray gun section to power up the monochromated aluminum K alpha x-ray source. After this, click the On button in the Neutralizer section to turn on the charge neutralizer.

In the Analyzer section, select the spectrum Hybrid measurement mode from the mode and lens drop down menus. Next, input the desired parameters into the acquisition scan control section. Using the keypad, optimize the sample position to maximize the signal from the selected core level.

Then, acquire XPS data as outlined in the text protocol. In this study, an alternative approach for introducing samples into an ultra high vacuum XPS instrument is used to minimize oxidation after immersion in an acidic solution containing a corrosion inhibitor. The XPS data for a polished sample exhibits three prominent features:the iron 2p signal arises from the carbon-steel composing the sample.

The oxygen 1s signal derives from both a surface oxidic film and absorbates while the carbon 1s signal is due to an adventitious carbon. Submersion in either of the inhibited one molar HCL solutions results in significant changes to the corresponding overview spectrum. A nitrogen signal arises due to surface absorption of the inhibitor while the oxygen signal is nearly eliminated.

The higher resolution oxygen 1s and iron 2p spectral profiles indicate that surface oxidation of the polished sample has occurred resulting in iron oxides and hydroxides. These species are absent from the immersed samples indicating that little, if any, surface oxide or hydroxide remains. The effect of the ambient laboratory atmosphere on an inhibited interface is determined by transferring a sample inside a partially purged glove box.

This sample exposed to a higher concentration of oxygen exhibits signs of surface oxidation. Thus, surface oxidation is minimized only when sample transfer occurs inside a well purged glove box. After watching this video, you should have a good understanding of how to avoid oxidation of corrosion inhibitor matter interfaces prior to XPS measurements.

The procedure is relatively simple, and once mastered, the sample transfer step can be done in less than 30 minutes if it is performed properly. However, while undertaking the procedure, it is important not to touch the surface to be probed by XPS at any time during sample immersion or transfer. Finally, don't forget that working with acids can be hazardous and appropriate care should be taken.

Explore More Videos

XPSCorrosion InhibitorMetal InterfacesOxidationSample TransferCarbon-steel SubstrateHydrochloric Acid SolutionInert GasGlove BoxRelative HumidityNitrile GlovesSample Preparation

Related Videos

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry

05:48

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry

Related Videos

10K Views

The Evolution of Silica Nanoparticle-polyester Coatings on Surfaces Exposed to Sunlight

10:27

The Evolution of Silica Nanoparticle-polyester Coatings on Surfaces Exposed to Sunlight

Related Videos

10K Views

Potentiodynamic Corrosion Testing

08:43

Potentiodynamic Corrosion Testing

Related Videos

18.4K Views

Growth and Electrostatic/chemical Properties of Metal/LaAlO3/SrTiO3 Heterostructures

11:54

Growth and Electrostatic/chemical Properties of Metal/LaAlO3/SrTiO3 Heterostructures

Related Videos

10.8K Views

Metal Corrosion and the Efficiency of Corrosion Inhibitors in Less Conductive Media

10:05

Metal Corrosion and the Efficiency of Corrosion Inhibitors in Less Conductive Media

Related Videos

18.6K Views

Determining Tribocorrosion Rate and Wear-Corrosion Synergy of Bulk and Thin Film Aluminum Alloys

07:12

Determining Tribocorrosion Rate and Wear-Corrosion Synergy of Bulk and Thin Film Aluminum Alloys

Related Videos

11.9K Views

A Continuous-flow Photocatalytic Reactor for the Precisely Controlled Deposition of Metallic Nanoparticles

11:49

A Continuous-flow Photocatalytic Reactor for the Precisely Controlled Deposition of Metallic Nanoparticles

Related Videos

10.3K Views

Imaging Corrosion at the Metal-Paint Interface Using Time-of-Flight Secondary Ion Mass Spectrometry

07:24

Imaging Corrosion at the Metal-Paint Interface Using Time-of-Flight Secondary Ion Mass Spectrometry

Related Videos

8.7K Views

Preparation of Nanoparticles for ToF-SIMS and XPS Analysis

06:24

Preparation of Nanoparticles for ToF-SIMS and XPS Analysis

Related Videos

9K Views

Co-localizing Kelvin Probe Force Microscopy with Other Microscopies and Spectroscopies: Selected Applications in Corrosion Characterization of Alloys

12:18

Co-localizing Kelvin Probe Force Microscopy with Other Microscopies and Spectroscopies: Selected Applications in Corrosion Characterization of Alloys

Related Videos

3.4K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code