The mitral valve apparatus is a complex structure consisting of the mitral valve annulus, leaflets, chordae tendineae and left ventricular papillary muscles1,2. Pediatric mitral valve disease consists of an extensive range of morphologic abnormalities associated with congenital and acquired heart anomalies3. The description of the morphology of mitral valve disease and its underlying mechanisms are key parameters for the surgical planning4. This requires the use of accurate diagnostic imaging modalities. Echocardiography is established as one of the primary diagnostic techniques used in pediatric mitral valve disease5. Specifically, two-dimensional (2D) echocardiography in pediatric mitral valve disease remains the most widely used diagnostic method. However, due to the nature of 2D imaging, the sonographer, the cardiologist and the surgeon must mentally reconstruct this complex 3D structure to determine the pathological mechanisms.
With the ability to produce anatomically correct views and an infinite number of cut planes, three-dimensional (3D) echocardiography has the ability to enhance mitral valve imaging. The value of 3D echocardiography is shown in its ability to provide specific information about annular shape and dynamics, leaflet scallop prolapse and the zone of leaflet coaptation6,7. While 3D transesophageal echocardiography (TEE) has been shown to be the most accurate ultrasound modality in identifying adult mitral valve pathology8, 3D transthoracic echocardiography (TTE) is more feasible in children due to a better acoustic window. 3D TTE has been proven to be highly accurate in discerning simple vs. complex mitral valve lesions and the need for surgical intervention9. Additionally, acquiring a 3D volumetric dataset allows surgeons and cardiologists to collaborate in post-processing, further enhancing surgical planning.
3D TTE technology has continued to improve with advancement in probe technology, ultrasound processing power, and post-processing efficiencies. The current 3D matrix probes can now acquire a full volume single-beat data set at a volume rate of approximately 25 volumes per second10. It is possible to further increase the volume rate of a single-beat data set above 25 volumes per second depending on the ultrasound vendor, probe technology and volume optimization. However, if the ECG gated (sub volumes) full volume method is used, this number can more than double, providing volumes rates that are needed in children. The higher heart rates in children compared to adults require higher temporal 3D resolution for diagnostic accuracy. Additionally, the development of specific pediatric 3D probe technology allowed for a higher scanning frequency, providing better spatial resolution that is crucial regarding the small size of the mitral valve and its apparatus11. Despite all these technological improvements, the vendors have managed to produce probes with footprints adapted to the anatomy of small children to maintain an optimal acoustic window. Lastly, new post-processing features, such as a quick cropping tools, allow for efficient post-processing.
In this paper, we describe the technique for 3D TTE assessment of the mitral valve in children, which can be applied to any ultrasound system with 3D TTE application. Additionally, post-processing of the 3D data will be reviewed and its benefit in the surgical planning. Finally, we will discuss some clinical applications of 3D imaging in children and include some examples.