Method Article

Standardized Ileal Bladder Augmentation For Enterocystoplasty In Rats via Midline Laparotomy

DOI:

10.3791/71123

June 12th, 2026

In This Article

Summary

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

This protocol describes a standardized rat enterocystoplasty model using a pedicled, vascularized, and detubularized ileal patch with temporarily externalized urinary diversion via a cannula tube to achieve reproducible bladder augmentation.

Abstract

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Bladder augmentation using intestinal segments remains a cornerstone reconstructive procedure for patients with low-capacity or poorly compliant bladders when conservative therapies fail. Despite its clinical relevance, experimental progress and in-depth study are limited by the lack of standardized, reproducible protocols that reliably model surgical principles in a controlled preclinical setting. Here, we present a step-by-step rat enterocystoplasty protocol that uses a vascularized, detubularized ileal patch as a pedicled flap to augment the native bladder. The procedure includes midline laparotomy, controlled exposure, and stabilization of the bladder with holding sutures, urinary diversion via an exteriorized cannula tube Foley, isolation of a short ileal segment with an intact mesenteric pedicle, detubularization, and tension-free anastomosis with the bladder wall. Emphasis is placed on maintaining mesenteric perfusion, preventing pedicle torsion, ensuring watertight suturing, and securing catheter patency, which are critical for procedural success and reproducibility. Representative intraoperative validation using hyperspectral imaging (HSI) in eight non-survival rats demonstrated preserved tissue oxygenation and perfusion of the bowel segment after key operative steps, supporting tissue viability at the end of this procedure. Thus, this protocol provides a standardized experimental approach for reproducible surgical implementation of rat enterocystoplasty. Potential downstream applications of the model include the investigation of metabolic and electrolyte alterations, infection susceptibility, mucus production, and induction of dysplasia or malignancy, and remain to be addressed in future survival investigations.

Introduction

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

A physiological urinary bladder function is fundamental to maintaining a high quality of life, as effective urine storage and voiding are critical for continence, social well-being, and overall health. Disorders affecting bladder function can result in substantial morbidity, including urinary incontinence, recurrent infections, renal impairment, and a profound negative impact on daily life.

Both congenital and acquired bladder pathologies can cause significant functional impairment, often necessitating surgical intervention when conservative and pharmacological treatments prove insufficient. Congenital anomalies such as posterior urethral v....

Access restricted. Please log in or start a trial to view this content.

Protocol

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

All animal procedures outlined in this document were carried out within accredited facilities and have been granted approval by the institutional animal care and use committee (IACUC) of the Baden-Württemberg Regional Council in Karlsruhe, Germany (35-9185.81/G-62/23). Experimental animals were handled in accordance with institutional protocols and in compliance with German legislation governing animal welfare, as well as adhering to the guidelines set forth by the European Community Council (2010/63/EU) and the ARRIVE guidelines. Male Sprague-Dawley rats (n = 8), aged 8–12 weeks and weighing 400 g, obtained from Janvier Labs, were used following a one-week acclimatiz....

Access restricted. Please log in or start a trial to view this content.

Results

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

To confirm tissue viability after this protocol, tissue oxygenation and perfusion were assessed during the procedure in eight rats (Table 1). Before enterocystoplasty, hyperspectral imaging (HSI) of the small bowel was performed to visualize tissue oxygen saturation (StO₂) and perfusion (NIR) (Figure 5A.1). As a negative control, maximal hypoperfusion was induced by clamping of the aorta (Figure 5A.2). HSI of re.......

Access restricted. Please log in or start a trial to view this content.

Discussion

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

This work provides a reproducible surgical protocol for enterocystoplasty in rats using a midline laparotomy, extracorporeal cannulation, and incorporation of a detubularized ileal segment. The technique follows the principles described by Tizzoni and Foggi for bladder augmentation and adapts them to a rodent model by combining precise anesthesia, aseptic preparation, exteriorized cannulation for urine diversion, and the harvesting of a vascularized small‑bowel patch.

This protocol was c.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

No conflicts of interest declared.

Acknowledgements

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

The authors gratefully acknowledge the data storage service SDS@hd supported by the Ministry of Science, Research, and the Arts Baden-Württemberg (MWK) and the German Research Foundation (DFG) through grant INST 35/1314-1 FUGG and INST 35/1503-1 FUGG. Furthermore, the authors gratefully acknowledge the support from the NCT (National Center for Tumor Diseases in Heidelberg, Germany) through its structured postdoc program and the Surgical Oncology program. We also acknowledge the support through state funds approved by the State Parliament of Baden-Württemberg for the Innovation Campus Health + Life Science Alliance Heidelberg Mannheim from the structured post....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Atraumatic preparation forcepsAesculapFB395RDE BAKEY ATRAUMATA atraumatic forceps, straight
Blunt overholt clampsAesculapBJ012RBABY-MIXTER preparation and ligature clamp, bent, 180 mm
Cannula tube foley for flusing and diversionMdk Mart23-CA-CD-UL-CDCannula G18 (only the tube is used to flush the diversion cannula)
Carprofencp pharma115Carprofen 0,5% (5% with 50 mg/mL diluted 1:10) (Carprosol)
Cotton whool swabsAmazonASIN: B0FPDB8ZGSNon-sterile cotton whool swabs (autoclave for survival experiments)
Fast resorbable polyfilament 4-0 suturesCOVIDIENSV-494Single-armed polyfilament surgical suture from resorbable polyglactin with one P-13 needle
Fixation rodslegefirm‎500343896Tuning forks used as y-shaped metal fixation rods
Foley catheterB. Braun4242010-0220 Gauge 50 mm Introcan Safety 2 Catheter as diversion cannula
Gauze swabsMedrullASIN: B09164D1JGSterile gauze swabs
Heating padRoyal GardineerIP67Royal Gardineer Heating Pad Size S, 20 Watt
Hyperspectral imaging camera systemDiaspective VisionTIVITA Tissue HalogenHSI system for validation
IsofluranePiramal Critical CarePZN / EAN 09714675 / 4150097146757100% isoflurane 250 mL
Isoflurane vaporizerUNO ROESTVASTSTAAL BV180000002Isoflurane vaporizer
Isotonic sodium chloride solutionB. BraunASIN: B007PZJOQ40,9% sodium chloride solution
Ketaminecp pharma1202Ketamine 10% (100 mg/mL)
Metal cannulaBD (Beckton, Dickinson)301300BD Microlance 3 cannula 20 Gauge as preparation hooks
Neontal face maskasia connectionME03016-0Neontal face mask size #0 for neonate
Non-resorbable monofilament 4-0 suturesCOVIDIENSP-670Single-armed monofilament surgical suture from non-resorbable poly-propylene with one C-16 needle
Non-resorbable monofilament 6-0 suturesCOVIDIENVP-733-XDouble-armed monofilament surgical suture from non-resorbable poly-propylene with two CV-22 needles
Ophthalmic ointmentBayer Vital GmbH15786815% dexpanthenol
Plastic perfusor tubeM. Schilling GmbHS702NC150Connecting tube COEX 150 cm
Preparation scissorsAesculapBC177RJAMESON preparation scissors, bent, fine model, blunt/blunt, 150 mm (6")
Rat induction chamberwpiincEZ-1785Induction chamber for narcosis
Steel plateMaschinenbau Feld GmbHC010206Galvanized sheet plate, 40 x 50 cm, thickness 4.0 mm
Xylazinecp pharma1206Xylazine 0,2% (2% with 20 mg/mL diluted 1:10) (Xylavet)

Reprints and Permissions

Request permission to reuse the text or figures of this JoVE article

Request Permission

Tags

Bladder AugmentationIleal Bladder AugmentationEnterocystoplasty Rat ModelMidline LaparotomyDetubularized Ileal PatchMesenteric PerfusionTension Free AnastomosisHyperspectral ImagingUrinary DiversionCatheter Patency

Related Articles