Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section

10.4K views

Cited by 5

11:00 min

July 19th, 2016

10.3791/51288-v

July 19th, 2016

10.4K views
 , 

Stent implants in stenosed arterial curvatures are prone to "Type IV" failures involving the complete transverse fracture of stents and linear displacement of the fractured parts. We present a protocol for detection of secondary flow (vortical) structures in a curved artery model, downstream of clinically relevant "Type IV" stent failures.

Explore More Videos

Curved Artery Model

Chapters in this video

0:05

Title

1:00

Blood-analog Solution

1:56

Fabrication and Installation of Stent Models

3:27

Setup and Data Acquisition

6:24

Post-processing

8:15

Results: Flow Velocity Data Analysis

9:59

Conclusion