The Journal of Visualized Experiments (JoVE) is a peer reviewed, PubMed-indexed video journal. Our mission is to increase the productivity of scientific research.

Recommend to Librarian

Refine your search:

Containing Text
Filter by author or institution
GO
Filter by publication date
From:
October, 2006
Until:
Today
Filter by section
General
Neuroscience
Immunology and Infection
Clinical and Translational Medicine
Bioengineering
Applied Physics
Chemistry
 
 
Stents: Devices that provide support for tubular structures that are being anastomosed or for body cavities during skin grafting.
 JoVE General

Imaging In-Stent Restenosis: An Inexpensive, Reliable, and Rapid Preclinical Model


JoVE 1346 9/14/2009

1Department of Cardiothoracic Surgery, Stanford University School of Medicine, 2Stanford University School of Medicine

This video demonstrates how to use a preclinical inexpensive and reliable model to study pathobiological and pathophysiological processes of in-stent restenosis development. Longitudinal in vivo monitoring using OCT (Optical Coherence Tomography) and analysis of OCT images are also demonstrated.

 JoVE Clinical and Translational Medicine

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis


JoVE 50233 5/14/2013

1Institute for Molecular Cardiovascular Research, RWTH Aachen University, 2Institute for Textile Technology and Mechanical Engineering, RWTH Aachen University, 3Institute for Applied Medical Engineering, Helmholtz-Institute of RWTH Aachen University, 4Department of Experimental Molecular Imaging, RWTH Aachen University, 5Department of Oral and Maxillofacila Surgery, RWTH Aachen University

A model of stent implantation in mouse carotid artery is described. Compared to other similar methods, this procedure is very rapid, simple and accessible, offering the possibility to study in a convenient way the vascular wall reaction to different drug-eluting stents and the molecular mechanisms of restenosis.

 JoVE Immunology and Infection

Colon Ascendens Stent Peritonitis (CASP) - a Standardized Model for Polymicrobial Abdominal Sepsis


JoVE 2299 12/18/2010

Department of Surgery, University of Greifswald

The Colon Ascendens Stent Peritonitis (CASP) is a highly standardized model for polymicrobial abdominal sepsis in rodents. This article describes the surgical procedure of CASP. The CASP model and its variants allow the systematic investigation of various problems concerning the subject of sepsis.

 JoVE Clinical and Translational Medicine

Human Internal Mammary Artery (IMA) Transplantation and Stenting: A Human Model to Study the Development of In-Stent Restenosis


JoVE 3663 5/09/2012

1University Heart Center Hamburg, TSI-Lab, Germany, 2Cardiovascular Research Center, University of Hamburg, 3Department of Medicine, Cardiology Division, Pulmonary Hypertension Program, University of Alberta, 4Department of Medicine, Stanford University School of Medicine, 5Department of Biomedical Sciences, Institute of Physiology, Pathophysiology, and Biophysics, University of Veterinary Medicine, Vienna, 6Translumina GmbH, Hechingen, 7Department of Cardiothoracic Surgery, Stanford University School of Medicine

This video shows a model to study the development of intimal hyperplasia after stent deployment using a human vessel (IMA) in an immunodeficient rat model.

 JoVE Clinical and Translational Medicine

Surgical Procedures for a Rat Model of Partial Orthotopic Liver Transplantation with Hepatic Arterial Reconstruction


JoVE 4376 3/07/2013

1Institute for Laboratory Animal Science and Experimental Surgery, RWTH-Aachen University, 2Department of Hepato-Biliary-Pancreatic Surgery and Transplantation, Graduate School of Medicine, Kyoto University

Orthotopic liver transplantation in rats is an indispensable experimental model for biomedical research. Here we present our surgical procedures for orthotopic rat liver transplantation with hepatic arterial reconstruction using a 50% partial graft.

 JoVE Clinical and Translational Medicine

Orthotopic Liver Transplantation in Rats


JoVE 4143 7/01/2012

1Transplantation Division, Department of Surgery, University of Geneva Hospitals, 2Department of Surgery, University of Pavia, 3Department of Surgery, University of Geneva, 4Division of Abdominal Surgery, Department of Surgery, University of Geneva Hospitals

We present an easy-to-establish revision of the classical two-cuff technique for orthotopic liver transplantation in rat.

 JoVE Bioengineering

Graphene Coatings for Biomedical Implants


JoVE 50276 3/01/2013

1Department of Physics, Clemson University, 2Department of Pharmacology and Toxicology, East Carolina University, 3Department of Bioengineering, Clemson University, 4Center for Optical Materials Science and Engineering Technologies, Clemson University

Graphene offers potential as a coating material for biomedical implants. In this study we demonstrate a method for coating nitinol alloys with nanometer thick layers of graphene and determine how graphene may influence implant response.

 JoVE Clinical and Translational Medicine

A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis


JoVE 50124 12/28/2012

1Orvis School of Nursing, University of Nevada, Reno, 2The State University of New York at Buffalo, St. Joseph's Medical Center, 3Strong Memorial Hospital, University of Rochester Medical Center

Continuous 12-lead electrocardiographic (ECG) monitoring can identify transient myocardial ischemia, even when asymptomatic, among patients with suspected acute coronary syndrome (ACS). In this article we describe our method for initiating patient monitoring using a Holter device, downloading the ECG data for off-line analysis, and how to utilize the ECG software to identify transient ischemia.

 JoVE Clinical and Translational Medicine

Using Quantitative Real-time PCR to Determine Donor Cell Engraftment in a Competitive Murine Bone Marrow Transplantation Model


JoVE 50193 3/07/2013

Division of Hematology-oncology, Department of Medicine, Medical University of South Carolina

Determining donor cell engraftment presents a challenge in mouse bone marrow transplant models that lack well-defined phenotypical markers. We described a methodology to quantify male donor cell engraftment in female transplant recipient mice. This method can be used in all mouse strains for the study of HSC functions.

 JoVE Clinical and Translational Medicine

In vivo Near Infrared Fluorescence (NIRF) Intravascular Molecular Imaging of Inflammatory Plaque, a Multimodal Approach to Imaging of Atherosclerosis


JoVE 2257 8/04/2011

1Cardiovascular Research Center and Cardiology Division, Massachusetts General Hospital, Harvard Medical School, 2Institute for Biological and Medical Imaging, Helmholtz Zentrum München und Technische Universität München, 3Department of Electrical and Computer Engineering, Northeastern University

We detail a new near-infrared fluorescence (NIRF) catheter for 2-dimensional intravascular molecular imaging of plaque biology in vivo. The NIRF catheter can visualize key biological processes such as inflammation by reporting on the presence of plaque-avid activatable and targeted NIR fluorochromes. The catheter utilizes clinical engineering and power requirements and is targeted for application in human coronary arteries. The following research study describes a multimodal imaging strategy that utilizes a novel in vivo intravascular NIRF catheter to image and quantify inflammatory plaque in proteolytically active inflamed rabbit atheromata.

 JoVE Clinical and Translational Medicine

Implantation of a Carotid Cuff for Triggering Shear-stress Induced Atherosclerosis in Mice


JoVE 3308 1/13/2012

1European Institute for Molecular Imaging, Westfälische Wilhelms-University Münster, 2British Heart Foundation Cardiovascular Sciences Unit, Imperial College London, 3Department of Bioengineering, Imperial College London, 4Biomedical Engineering, Eindhoven University of Technology

The constricting cuff presented in this article is designed to induce atherosclerosis in the murine common carotid artery. Due to the conical shape of its inner lumen the implanted cuff generates well-defined regions of low, high and oscillatory shear stress triggering the development of atherosclerotic lesions of different inflammatory phenotypes.

 JoVE Bioengineering

Autologous Endothelial Progenitor Cell-Seeding Technology and Biocompatibility Testing For Cardiovascular Devices in Large Animal Model


JoVE 3197 9/09/2011

1Department of Biomedical Engineering, Duke University, 2School of Medicine, Duke University, 3Department of Surgery, Duke University Medical Center, 4School of Medicine, University of Pennsylvania

A method for seeding titanium blood-contacting biomaterials with autologous cells and testing biocompatibility is described. This method uses endothelial progenitor cells and titanium tubes, seeded within minutes of surgical implantation into porcine venae cavae. This technique is adaptable to many other implantable biomedical devices.

More Results...
Waiting
simple hit counter