A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section

10.5K views

⸱

DOI:

10.3791/51288

⸱

July 19th, 2016

 , 

In This Article

Summary

Stent implants in stenosed arterial curvatures are prone to "Type IV" failures involving the complete transverse fracture of stents and linear displacement of the fractured parts. We present a protocol for detection of secondary flow (vortical) structures in a curved artery model, downstream of clinically relevant "Type IV" stent failures.

Abstract

The arterial network in the human vasculature comprises of ubiquitously present blood vessels with complex geometries (branches, curvatures and tortuosity). Secondary flow structures are vortical flow patterns that occur in curved arteries due to the combined action of centrifugal forces, adverse pressure gradients and inflow characteristics. Such flow morphologies are greatly affected by pulsatility and multiple harmonics of physiological inflow conditions and vary greatly in size-strength-shape characteristics compared to non-physiological (steady and oscillatory) flows 1 - 7.

Secondary flow structures may ultimately influence the wall shear stress and exposure time of blood-borne particles toward progression of atherosclerosis, restenosis, sensitization of platelets and thrombosis 4 - 6, 8 - 13. Therefore, the ability to detect and characterize these structures under laboratory-controlled conditions is precursor to further clinical investigations.

A common surgical treatment to atherosclerosis is stent implantation, to open up stenosed arteries for unobstructed blood flow. But the concomitant flow perturbations due to stent installations result in multi-scale secondary flow morphologies 4 - 6. Progressively higher order complexities such as asymmetry and loss in coherence can be induced by ensuing stent failures vis-à-vis those under unperturbed flows 5. These stent failures have been classified as "Types I-to-IV" based on failure considerations and clinical severity 14.

This study presents a protocol for the experimental investigation of the complex secondary flow structures due to complete transverse stent fracture and linear displacement of fractured parts ("Type IV") in a curved artery model. The experimental method involves the implementation of particle image velocimetry (2C-2D PIV) techniques with an archetypal carotid artery inflow waveform, a refractive index matched blood-analog working fluid for phase-averaged measurements 15 - 18. Quantitative identification of secondary flow structures was achieved using concepts of flow physics, critical point theory and a novel wavelet transform algorithm applied to experimental PIV data 5, 6, 19 - 26.

Introduction

Secondary flow structures are vortical flow patterns that occur in internal flow geometries with curvatures such as curved pipes and channels. These vortical structures arise due to the combined action of centrifugal forces, adverse pressure gradients and inflow characteristics. In general, secondary flow structures appear in planar cross-sections of curved pipes as symmetric Dean-type vortices under steady inflow and, symmetric Dean- and Lyne-type vortices under oscillatory inflow conditions 1 - 3. Secondary flow morphologies are greatly affected by pulsatility and multiple harmonics of pulsatile, physiological inflow conditions. These structures acquire m....

Access restricted. Please log in or start a trial to view this content.

Protocol

1. Design and Fabrication of Stent Models

Note: The following steps have been followed to create laboratory-scale models of straight and curved stents. The installation of the two stent models will embody a "Type IV" fracture (fragmentation and linear displacement of fractured stent parts).

Note: The authors used Pro/Engineer software at the time of the research for creating CAD models of the stent geometry. The procedure below is generalized and may not include terms generic to the CAD software used. Other CAD packages available can also be used. The steps that follow are applicable for the CAD software that the a....

Access restricted. Please log in or start a trial to view this content.

Results

Results presented in Figure 7A-D were generated after post processing secondary flow velocity data (see Figures 5, 6) acquired from 2C-2D PIV system shown in Figure 3A. The inflow condition supplied to the curved artery test section with an idealized "Type IV" stent fracture was the carotid artery waveform shown in Figure 4B. Our previous studies have demonstrated the sensitivity of secondary flow structures to decelerati.......

Access restricted. Please log in or start a trial to view this content.

Discussion

The protocol presented in this paper describes the acquisition of high fidelity experimental data using particle image velocimetry technique (PIV) and coherent structure detection methods, viz., continuous wavelet transforms, Q and λ<sub>ci</sub> criteria equation; relevant for physics analysis, optimization methods., suited for identification of vortex and shear-dominated flows. Analysis of experime.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Acknowledgements

The authors acknowledge support from NSF grant CBET-0909678 and funding from the GW Center for Biomimetics and Bioinspired Engineering (COBRE). We thank the students, Mr. Christopher Popma, Ms. Leanne Penna, Ms. Shannon Callahan, Mr. Shadman Hussain, Mr. Mohammed R. Najjari, and Ms. Jessica Hinke for help in the laboratory and Mr. Mathieu Barraja for assisting in CAD drawings.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Acrylic tubes and sheetMcMaster-Carr Supply CompanyInlet and outlet pipes and material of the curved artery test section
Object24 Desktop 3D printerStratasysDesktop rapid prototyping machine. http://www.stratasys.com
VeroWhitePlus Opaque materialStratasysBuilding material for Object24 Desktop 3D printer
Fullcure 705StratasysNon-toxic gel-like photopolymer Support material for Object24 Desktop 3D printer
Ubbelohde viscometerCole ParmerYO-98934-12Toward measurement of kinematic viscosity of the blood-analog fluid
VELP scientifica - ESP stirrer VELP ScientificaF206A0179Magnetic stirrer
Ohaus Scout Pro SP 601 The Lab DepotSP4001Weigh scale
RefractometerAtagoPAL-RIToward measurement of refractive index of blood-analog fluid
Beakers, pipettes, syringes and spatulaSigma-Aldrich CLS710110,  CLS10031L, CLS71015, CLS71011 Z193216Toward handling materials required for blood-analog solution preparation
Sodium IodideSigma-Aldrich383112-2.5KG Crystalline
GlycerolSigma-AldrichG5516-1LLiquid
Deionized Water--Liquid
Sodium thiosulfate anhydrousSigma-Aldrich72049-250GPowder
PIV Recording mediumLaVisionImager Intense 10HzPIV Image acquisition CCD camera
PIV Illumination sourceNew Wave ResearchSolo III-15PIV Laser source, Nd:YAG laser, 532 nm, dual pulse 70 mJ/pulse
PIV Imaging softwareLaVisionDaVis 7.2PIV data acquisition and instrument control
PIV Seeding materialThermo-scientific  Flouro-MaxRed fluorescent polymer microspheres (≈ 7 µm); Dry dyed polystyrene (DVB) fluorescent microspheres emit bright and distinct colors when illuminated by the light of shorter  wavelengths than the emission wavelength. 

References

  1. Dean, W. R. Note on the motion of a fluid in a curved pipe. Phil Mag. 7, 208-223 (1927).
  2. Dean, W. R. The streamline motion of a fluid in a curved pipe. Phil Mag. 7, 673-695 (1928).
  3. Lyne, W. H.

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Curved Artery ModelParticle Image VelocimetryBlood-Analog SolutionRefractive Index MatchingWavelet Transform AlgorithmQ-Criterion AnalysisSwirling Strength DetectionCarotid Artery Waveform