方法文章

Purification of Adeno-Associated Virus Particles by Polyethylene Glycol Precipitation and Ultracentrifugation

10 次观看

⸱

2026年10月29日

本文内容

摘要

Source: Zhang, T., et al. Streamlined and Standardized Procedure for Generating High-Titer, High-Quality Adeno-Associated Virus Vectors Utilizing a Cell Factory Platform. J. Vis. Exp. (2024).

This video demonstrates the purification of adeno-associated virus (AAV) from an infected mammalian cell culture. It shows how polyethylene glycol and salt are used to aggregate the viral particles, followed by centrifugation and density gradient separation to isolate full AAV capsids. Finally, the process includes dialysis and concentration steps to obtain purified virus for downstream analysis.

方案

1. AAV purification by iodixanol gradient ultracentrifugation

  1. Prepare the iodixanol gradients freshly before loading the AAV according to the number of ultracentrifugation tubes used (Table 1).
    NOTE: Phenol red was used to observe the layers.
  2. Overlay each solution into a round-top polypropylene ultracentrifuge quick-seal tube slowly using a 10 mL syringe attached with a 16 G punted long needle. Avoid bubbles.
  3. Carefully add up to 17 mL of AAV solution on top of the gradient with a 22 G syringe. Use AAV dialysis buffer to top off the tube.
    NOTE: Add the AAV solution by loading drops against the wall in the ultracentrifuge tube. Don't disturb the gradient layers.
  4. Seal the ultracentrifuge tubes with an electric sealer.
    NOTE: Balance the tubes before sending them to ultracentrifuge with ±0.2 g difference.
  5. Centrifuge at 350,000 x g for 2 h in a Ti70 rotor at 4 °C.
  6. Carefully remove the tubes from the rotor and place them in the ultracentrifuge tubes rack.
    NOTE: Ensure that the gradients are not disturbed.
  7. Collect AAV fractions following the steps below:
    1. Stabilize the tube on a stand holder.
    2. Puncture the ultracentrifuge tubes slightly below the 40%-60% interface with a 19 G needle attached to a 10 mL syringe.NOTE: The opening of the needle should be up, facing the 40% gradient.
    3. Punch a hole in the top of the tube with a 16 G needle.
    4. Collect up to 5 mL per tube. Avoid collecting the protein contamination at the 25%-40% interface.
    5. Repeat for each ultracentrifuge tube.
      NOTE: Transfer the AAV fractions to a 50 mL conical tube.

2. Second round iodixanol gradients ultracentrifugation

NOTE: This step is optional. This step is to reduce the empty AAV ratio for a higher quality full AAV capsid.

  1. Dilute AAV >1:1 with AAV dialysis buffer.NOTE: AAV collected from the first round of ultracentrifugation was at 40% iodixanol layer. It should be diluted by at least 50% to be able to be loaded on top of the 30% iodixanol layer.
  2. Overlay each solution (Table 2) into an ultracentrifugation tube using a 16 G punted needle and slowly attach a 10 mL syringe. Avoid bubbles.
  3. Carefully add 20 mL of diluted AAV solution on top of the gradient with a 22 G syringe. Use AAV dialysis buffer to top off the tube.
  4. Repeat the steps 6.4 to 6.7.

3. AAV dialysis and concentration

  1. Transfer the AAV virus into the dialysis cassette using a new 18 G needle and 10 mL syringe. Slowly inject the virus into the cassette and remove air from it.
  2. Add a stir bar to the beaker containing AAV dialysis buffer and place it on a stir plate.
  3. Put the dialysis cassette into the dialysis buffer with a float buoy. Stir at 4 °C. Change 2-3 times the AAV dialysis buffer.
    NOTE: Use enough buffer to allow the cassette to float and perform the buffer exchange. Cover the beaker with aluminum foil.
  4. Using a 10 mL syringe attached with an 18 G needle, collect the virus from the cassette into a centrifugal filter unit.
  5. Centrifuge at 4,000 x g for 15-30 min at 4 °C.
    NOTE: Rince the AAV with AAV dialysis buffer 2-3 times. Concentrate the AAV until ~200 µL of remaining is on top of the filter.
  6. Collect the concentrated AAV from the filter unit. Rinse the filter with another 300 µL of AAV dialysis buffer and transfer it to the concentrated AAV.
  7. Filter the virus through a 0.22 µm syringe filter using a 1 mL tuberculin luer slip syringe. To ensure the least amount of volume loss, use the 10 mL syringe to push air through the filter 2-3 times.
  8. Store the purified AAV virus at 4 °C temporally for titration.
    NOTE: Titrate the virus, aliquot, and store at -80 °C within 1 week.
Table 1. Preparation of iodixanol gradient.     
Volume of each layer (mL)LayerNumber of gradients
%Solutions (mL)12468
615DPBS + high salt59.919.829.739.6
60% iodixanol1.73.36.69.913.2
625DPBS + low salt3.97.715.423.130.8
60% iodixanol2.85.51116.522
Phenol red0.10.10.20.30.4
540DPBS + low salt1.83.77.31114.7
60% iodixanol3.77.314.72229.3
560DPBS + low salt5.511223344
Phenol red0.10.10.20.30.4
Table 2. Preparation of second round iodixanol gradient.    
Volume of each layer (mL)LayerNumber of gradients
%Solutions (mL)12468
830DPBS + low salt48162432
60% iodixanol4.18.216.424.632.8
Phenol red0.10.20.40.60.8
540DPBS + low salt1.83.77.31114.7
60% iodixanol3.77.314.72229.3
560DPBS + low salt5.511223344
Phenol red0.10.10.20.30.4

材料

本文使用的材料清单
姓名公司目录编号评论
40% PEG solutionSigmaP1458-50ML 
AAV6 reference full capsidsCharles River LaboratoriesRS-AAV6-FL 
Centrifugal Filter UnitMilliporeSigmaUFC905024 
Corning PES Syringe FiltersFisher Scientific09-754-29 
Dialysis Cassettes, 10 K MWCOFisher ScientificPI66810 
Disposable PES Filter Units 1 L 0.2 µmFisher ScientificFB12566506 
Disposable PES Filter Units 1 L 0.45 µmFisher ScientificFB12566507 
Disposable PES Filter Units 500 mL 0.2 µmFisher ScientificFB12566504 
pAAV-CMV-GFPAddgene105530 
pAAV-DJCell BioLabVPK-420-DJ 
pAAV-RC6Cell BioLabVPK-426 
pAdDeltaF6Addgene112867 
PEG 8000PromegaV3011 
Type 70 Ti Fixed-Angle Titanium RotorBeckman Coulter337922 

探索更多文章

病毒纯化密度梯度病毒颗粒分离聚乙二醇沉淀透析盒离心滤膜AAV浓缩