RESEARCH
Peer reviewed scientific video journal
Video encyclopedia of advanced research methods
Visualizing science through experiment videos
EDUCATION
Video textbooks for undergraduate courses
Visual demonstrations of key scientific experiments
BUSINESS
Video textbooks for business education
OTHERS
Interactive video based quizzes for formative assessments
Products
RESEARCH
JoVE Journal
Peer reviewed scientific video journal
JoVE Encyclopedia of Experiments
Video encyclopedia of advanced research methods
EDUCATION
JoVE Core
Video textbooks for undergraduates
JoVE Science Education
Visual demonstrations of key scientific experiments
JoVE Lab Manual
Videos of experiments for undergraduate lab courses
BUSINESS
JoVE Business
Video textbooks for business education
Solutions
Language
zh_CN
Menu
Menu
Menu
Menu
A subscription to JoVE is required to view this content. Sign in or start your free trial.
Research Article
Please note that some of the translations on this page are AI generated. Click here for the English version.
Erratum Notice
Important: There has been an erratum issued for this article. View Erratum Notice
Retraction Notice
The article Assisted Selection of Biomarkers by Linear Discriminant Analysis Effect Size (LEfSe) in Microbiome Data (10.3791/61715) has been retracted by the journal upon the authors' request due to a conflict regarding the data and methodology. View Retraction Notice
该协议描述了使用定制尺寸的3D打印夹具对肌腱进行高效和可重复的拉伸生物力学测试方法。
肌腱疾病是常见的,影响所有年龄的人,并经常使人衰弱。标准治疗,如消炎药、康复和手术修复,往往失败。为了定义肌腱功能并展示新疗法的疗效,必须准确确定动物模型中肌腱的机械特性。鼠种模型现在被广泛用于研究肌腱疾病和评估肌腱病的新疗法;然而,确定小鼠肌腱的机械特性一直具有挑战性。在这项研究中,为肌腱机械测试开发了一个新的系统,其中包括三维打印的固定装置,这些装置与腐殖质和钙化物的解剖完全匹配,分别用于机械地测试上皮肌腱和跟腱。这些夹具是使用原生骨解剖、固体建模和增材制造的 3D 重建来开发的。新方法消除了工件夹持故障(例如,生长板故障而不是肌腱故障),减少了总体测试时间,并增加了可重复性。此外,这种新方法很容易适应测试其他动物的其他肌腱和肌腱。
肌腱疾病在老化、运动和活跃人群1、2、3中很常见和高度流行。在美国,每年有1640万结缔组织损伤报告,占所有与伤害有关的医生办公室就诊人数的30%, 8.最常见的受影响的部位包括旋转手铐,跟腱,和骨腱9。虽然已经探索了各种非手术和手术治疗,包括消炎药、康复和手术修复,但效果仍然很差,恢复功能有限,失败率高5 6.这些不良的临床结果促使基础和翻译研究寻求了解肌腱病,并开发新的治疗方法。
拉伸生物力学特性是定义肌腱功能的主要定量结果。因此,肌腱病变和治疗效果的实验室表征必须包括对肌腱拉伸特性的严格测试。许多研究描述了从动物模型(如大鼠、绵羊、狗和兔子10、11、12)中确定肌腱的生物力学特性的方法。然而,很少有研究测试过肌腱的生物力学特性,这主要是因为难以抓住小组织进行拉伸测试。由于鼠模型在机械研究肌腱病方面有许多优点,包括基因操作、广泛的试剂选择和低成本,因此需要开发准确、高效的生物力学方法来检测鼠组织。
为了正确测试肌腱的机械特性,必须有效地抓住组织,而不会在抓斗界面处打滑或被工器撕裂或生长板破裂。在许多情况下,特别是对于短肌腱,骨头被抓住一端,肌腱抓住另一端。骨骼通常通过嵌入环氧树脂13和聚甲基丙烯酸酯14、15等材料来固定。肌腱通常放置在两层沙纸之间,用氰丙烯酸酯粘附,并使用压缩夹(如果横截面平坦)或冷冻介质(如果横截面较大)15、16、17 固定.这些方法已应用于生物力学试验鼠肌腱,但由于标本体积小,生长板的符合性,从未出现过18种,因此出现了挑战。例如,鼠头的直径只有几毫米,因此很难抓住骨头。具体来说,对肌腱到骨骼样本的拉伸测试通常会导致生长板的失效,而不是在肌腱或肌腱上。同样,对跟腱进行生物力学测试也极具挑战性。虽然跟腱比其他肌腱大,但卡内肌很小,使得抓住这个骨头变得困难。骨骼可以去除,然后抓住两个肌腱末端;然而,这排除了肌腱到骨骼附件的测试。其他团体报告使用定制的夹具19,20,锚定在夹21,固定在自固化塑料水泥22或使用锥形槽22,但这些以前的方法仍然受到低重现性、高夹持故障率和繁琐的准备要求的限制。
目前的研究目标是开发一种准确而有效的方法,用于对肌腱进行拉伸生物力学测试,以上皮肌腱和跟腱为例。利用来自原生骨骼解剖、实体建模和增材制造的 3D 重建组合,开发了一种控制骨骼的新方法。这些夹具有效地固定了骨骼,防止了生长板故障,减少了试样制备时间,并增加了测试的可重复性。新方法很容易适应测试其他鼠肌腱以及大鼠和其他动物的肌腱。
动物研究得到了哥伦比亚大学机构动物护理和使用委员会的批准。本研究中使用的小鼠具有 C57BL/6J 背景,是从杰克逊实验室(美国梅港巴港)购买的。他们被安置在无病原体屏障条件下,并向他们提供食物和水。
1. 开发用于夹持骨的定制贴合 3D 打印夹具
2. 鼠腱的生物力学试验
3D打印的固定装置用于测试8周大的鼠超脊柱和跟腱。所有经过机械测试的样品在检测时均失败,其特点是微CT扫描、目视检查和拉伸测试后的视频分析。图3对实验室中以前和当前超皮肌腱测试方法的一对一比较。在上一种方法28,29,30中,腐殖质骨被嵌入环氧树脂中,一个回形针被放置在腐殖质头部,以防止生长板断裂。需要4-6小时才能使环氧树脂完全固化(图3),只允许6-8个样本在典型的一天内进行测试。该方法的进一步限制是回形针放置的与用户相关的有效性,以防止生长板断裂。使用这些先前方法的测试结果是高度可变的,大多数参数的变化系数约为30%,生长板故障率约为10%~20%。如图3所总结,使用新方法的试样制备时间缩短至5~10分钟,因此每天测试16-20个样品是可行的。此外,还消除了生长板故障。
与其他人报告用于测试肌腱的方法相比,14、15、17、25、28、29、30、31 ,32,33, 新方法更有效,更可重复.对于超脊柱肌腱,结构特性(如最大负载(3.8 ± 0.6 N)和刚度(12.7 ± 1.8 N/mm))以及标准化材料特性(如最大应力(8.7 ± 3.0 MPa)和模量(51.7 ± 13.5 MPa)的系数大大降低。与文献结果相比的变化(表1)。对于跟腱,机械特性,如最大负载(7.8 ± 1.1 N)和刚度(13.2 ± 1.9 N/mm)与文献19、21、22的结果相比,变化系数较低,32,33,34,35,36,37,38, 而最大应力 (24.2 × 5.4 MPa) 和模量 (73.2 °22.1 MPa) 的变异系数与文献中报告的系数相似(表2)。
动物性对上皮肌腱和跟腱的机械特性有显著影响(图4)。当比较雄性和雌性上皮肌腱时,最大力(p = 0.002)和工作屈服(p = 0.008)显著增加。两组之间有刚度(p = 0.057)、应力(p = 0.068)、模量(p = 0.061)和弹性(p = 0.078)之间的趋势。当比较男性和女性跟腱时,最大应力(p = 0.0006)和弹性(p = 0.0019)显著增加。两组工作屈服(p = 0.079)和模量(p = 0.074)之间存在趋势,最大力(p = 0.1880)和刚度(p = 0.6759)无差异。

图 1:用于腐殖质(上行)和卡卡内乌斯(下排)的夹具的代表性 3D 模型。(A) 骨骼的 3D 模型.(B) 拆卸的夹具型号。(C) 夹具的装配型号。请点击此处查看此图的较大版本。

图 2:代表性的 3D 打印夹具。(A) 用于在腐殖质和上皮肌腱之间以 180° 角对 8 周大小鼠的上皮肌腱进行生物力学测试的夹具。(B) 用于8周大小鼠上皮肌腱的生物力学测试夹具,其角度为胡同肌腱和上皮肌腱之间的角度为135°。(C) 用于在钙化物和跟腱之间以 120° 角对鼠跟腱进行生物力学测试的夹具。(D) 用于对成年斯普拉格道利大鼠的上皮肌腱进行生物力学测试的夹具,在腐殖质和上皮肌腱之间的角度为 180°。比例尺:5毫米。请点击此处查看此图的较大版本。

图3:对鼠皮上肌腱进行机械测试的以往和当前方法的比较。(A) 在机械测试之前,我们实验室使用以前的标本制备方法:腐殖质被灌在环氧树脂中,以稳定骨骼,将回形针放在腐殖质头上,以防止生长板断裂,以及对于环氧树脂固化,在机械测试前将样品留在室温中4-6小时。(B) 当前研究中使用的标本制备方法(步骤 1.2 和 2.1.4):左上角显示由实体建模程序生成的夹具的 3D 表示形式。3D 打印夹具可重复使用,易于组装和拆卸。试样骨端插入夹具中,固定生长板并露出肌腱进行夹持和测试。肌腱末端粘在折叠的薄纸巾之间,并插入手柄。每个试样的准备时间是10~15分钟。(C) 使用现有方法用于超皮肌腱拉伸测试的代表性载荷变形曲线。(D) 代表载荷变形曲线,用于超皮肌腱的拉伸测试,显示生长板故障。请点击此处查看此图的较大版本。

图4:对超皮质(SST)和阿基里斯(ACHT)肌腱的机械特性的性影响。基于未配对的t-测试([性效应,p<0.05)》,性对许多机械特性有显著影响。数据显示为均值 = 标准偏差。请点击此处查看此图的较大版本。

图5:微CT的横截面面积测量。(A) 沿上皮肌腱长度的最小横截面面积测量。(B) 沿跟腱长度的最小横截面面积测量。应仅选择肌腱本身进行测量。请点击此处查看此图的较大版本。
| 结构属性 | 材料属性 | |||||||||
| 动物 | 最大力 (N) | 硬度(N/mm) | 最大应力(Mpa) | 模组 (MPa) | ||||||
| 作者 | N | 背景 | 平均 = SD | COV(%) | 平均 = SD | COV (%) | 平均 = SD | COV (%) | 平均 = SD | COV (%) |
| 比森等人《肩部和肘部手术杂志》(2013)15 | 10 | C57Bl/6 | 0.93±0.34 | 36.56 | 95.1[39.8] | 41.85 | 3.40±1.56 | 45.88 | 312.8±127.0 | 40.60 |
| 贝尔等人骨科研究杂志(2014)31 | 6 | C57Bl/6 | 1.22 ± 0.52 | 42.62 | 2.37 × 1.6 | 67.51 | 星期日 | 星期日 | ||
| 康等人骨科研究杂志(2018)17 | 8 | C57Bl/6 | 5.38 × 2.404# | 44.68 | 4.25 × 1.67# | 39.29 | 星期日 | 星期日 | ||
| 康尼佐等人生物医学工程年鉴(2014)32 | 10 | NR(db/+) | 星期日 | 84.44 ± 27.23° | 32.25 | 星期日 | 476 × 186.27° | 39.13 | ||
| 康尼佐等人生物医学工程杂志(2013)14 | 星期日 | C57/BL6 | 星期日 | 星期日 | 星期日 | 297 × 148.90* | 50.13 | |||
| 戴美尔等人Acta 生物材料(2019)28 | 12 | CD-1 IGS 鼠标 (WT) | 5.0 × 0.7 | 14 | 9.2 × 2.9 | 31.52 | 33 × 35 | 106.06 | 星期日 | |
| Eekhoff等人生物医学工程杂志(2017)33 | 13 | 埃尔恩 [/] | 星期日 | 8.50 ± 2.95 | 34.71 | 5.96 × 3.23 | 54.19 | 101.2 × 50.8 | 50.20 | |
| 基里安等人FASEB 杂志(2016)29 | 8 | C57BL/6 | 星期日 | 星期日 | 7.79 ± 2.61° | 33.50 | 58.32 ± 31.73° | 54.41 | ||
| 施瓦茨等人骨(2014)25 | 20 | CD-1 IGS 鼠标 (WT) | 4.11 ± 0.79° | 19.22 | 8.58 ± 3.78° | 44.06 | 12.29 ± 5.95° | 48.41 | 133.80 ± 59.41° | 44.40 |
| 施瓦茨等人发展(2015)30 | 12 | (罗萨-DTA (DTA) x Gli1-CreERT2 )ScxCre;斯莫夫尔/fl (WT) | 4.16 ± 0.29° | 6.97 | 11.04 ± 1.98° | 17.93 | 26.24 × 5.81 | 22.14 | 121.89 × 44.18 | 36.25 |
| 平均 COV | 27.34 | 平均 COV | 38.64 | 平均 COV | 51.70 | 平均 COV | 45.02 | |||
| 新方法 | 10 | C57BL/6J | 3.79 ± 0.62 | 16.41 | 12.73 × 1.81 | 14.20 | 8.71 × 3.04 | 34.91 | 51.67 × 13.54 | 26.20 |
表1:上皮肌腱的机械特性。平均 = SD 和变异系数 (COV),用于使用新方法估计的结构和材料属性 (COV),与文献中报告的方法相比。[NR:未报告,=从数字估计,*从报告的标准误差计算的标准偏差,*使用光学染色线测量变形*。
| 结构属性 | 材料属性 | |||||||||
| 动物 | 最大力 (N) | 硬度(N/mm) | 最大应力(Mpa) | 杨的模量 (MPa) | ||||||
| 作者 | N | 背景 | 平均 = SD | COV(%) | 平均 = SD | COV (%) | 平均 = SD | COV (%) | 平均 = SD | COV (%) |
| Boivin等人的肌肉,韧带和肌腱杂志 (2014)19 | 6 | 非糖尿病精益控制小鼠 | 8.1 × 0.6 | 7.41 | 3.9 × 0.7 | 17.95 | 星期日 | 16 × 3.7 | 23.13 | |
| 康尼佐等人生物医学工程年鉴 (2014)32 | 10 | db/* | 星期日 | 20.39 ± 2.43° | 11.92 | 星期日 | 152.94 × 44.12° | 28.85 | ||
| Eekhoff等人生物力学工程杂志 (2017)33 | 8 | 埃尔恩 [/] | 星期日 | 18.86 × 3.37 | 17.87 | 10.55 × 2.97 | 28.15 | 443.8 × 131.7 | 29.68 | |
| Mikic等人骨科研究杂志 (2006)34 | 20 | C57BL/6-J x 129SV/J | 星期日 | 星期日 | 18 × 5 | 27.78 | 61 × 20 | 32.79 | ||
| Probst等人调查性外科杂志 (2000)22 | 20 | 巴尔布/c | 8.4 × 1.1 | 13.10 | 6.3 × 1.2 | 19.05 | 星期日 | 星期日 | ||
| Shu 等人对等 J (2018)21 | 9 | C57BL/6 | 9.6 × 3.84 | 39.96 | 8.19 × 3.63 | 44.32 | 27.55 × 10.54 | 38.26 | 星期日 | |
| Sikes等人骨科研究杂志 (2018)35 | 7 | C57BL/6 | 星期日 | 星期日 | 19.53 × 7.03 | 0.36 | 62.82 × 20.20 | 32.16 | ||
| 王等人骨科研究杂志 (2006)36 | 9 | A/J | 8.4 × 1.2 | 14.29 | 12.2 × 2.8 | 22.95 | 78.2 × 8.6 | 11.00 | 713.9 × 203.7 | 28.53 |
| 王等人骨科研究杂志 (2006)36 | 8 | C57BL/6J | 10.2 × 1.4 | 13.73 | 13.1 × 2.5 | 19.08 | 97.4 × 11.4 | 11.70 | 765.1 × 179.6 | 23.47 |
| 王等人骨科研究杂志 (2006)36 | 7 | C3H/HeJ | 12.5 × 1.7 | 13.60 | 14.1 × 3.2 | 22.70 | 97.5 × 10.9 | 11.18 | 708.6 × 127.8 | 18.04 |
| 王等人骨科研究杂志 (2011)37 | 7 | C57BL/6 | 6.6 × 1.7 | 25.76 | 8.2 × 1.4 | 17.07 | 13.4 × 3.7 | 27.61 | 86.8 × 15.5 | 17.86 |
| 张等人矩阵生物学 (2016)38 | 星期日 | CD-1 和 C57BL/6J | 6.73 ± 3.74° | 55.57 | 12.03 ± 3.34° | 27.76 | 25.4 ± 15.14° | 59.61 | 632.31 × 113.79° | 18.00 |
| 平均 COV | 22.93 | 平均 COV | 22.07 | 平均 COV | 23.96 | 平均 COV | 25.25 | |||
| 新方法 | 12 | C57BL/6J | 7.8 ± 1.08 | 13.91 | 13.19 × 1.86 | 14.08 | 24.16 × 5.42 | 22.45 | 73.17 × 16.14 | 22.06 |
表2:跟腱的机械特性。均值 = SD 和 COV,用于使用新方法估计的结构和材料属性,与文献中报告的方法相比。[NR:未报告,= 从数字估计,= 从报告的标准误差计算的标准偏差]。
补充文件。 请点击此处下载此文件。
作者没有什么可透露的。
该协议描述了使用定制尺寸的3D打印夹具对肌腱进行高效和可重复的拉伸生物力学测试方法。
该研究得到了NIH/NIAMS(R01 AR055580,R01 AR057836)的支持。
| 琼脂糖 | Fisher Scientific | BP160-100 | Dissovle 1g 溶于 100 ml 超纯水中,制成 1% 琼脂糖 |
| 布鲁克 microCT | Bruker BioSpin Corp | Skyscan 1272 | 作者使用 |
| ElectroForce | TA Instruments | 3200 | 测试平台 |
| 乙醇 200 证明 | Fisher Scientific | A4094 | 稀释至 70% 并按照方案中的建议使用 |
| 固定装置连接夹具 | 定制 | 作者 | |
| Kimwipes | Kimberly-Clark | 使用S-8115 | 如方案中建议 |
| MicroCT CT 分析仪 (Ctan) | Bruker BioSpin Corp | 作者用于可视化和分析显微 CT 扫描 | |
| MilliQ 水 (超纯水) | Millipore Sigma | QGARD00R1 (或相关净化器) | 100 ml |
| Meshmixer | Autodesk | http://www.meshmixer.com/ | 作者用来优化网格 |
| Objet EDEN 260VS 的免费工程软件 | Stratasys LTD | 精密原型 | |
| Objet Studio | Stratasys LTD | 作者使用 | |
| PBS - 磷酸盐缓冲盐水 | ThermoFisher Scientific | 10010031 | 2.5 L of 10% PBS |
| S&T 镊子 | 精细科学工具 | 00108-11 | 作者使用 |
| 手术刀刀片 - #11 | 精细科学工具 | 10011-00 | 作者使用 |
| 手术刀手柄 - #3 | 精细科学工具 | 10003-12 | 作者使用 |
| SkyScan 1272 | Bruker BioSpin Corp | 作者用于可视化和分析显微 CT 扫描 | |
| Skyscan CT-Vox | Bruker BioSpin Corp | 作者用于可视化和分析显微 CT 扫描 | |
| SkyScan NRecon | Bruker BioSpin Corp | 作者用于可视化和分析显微 CT 扫描 | |
| SolidWorks CAD | Dassault Systèmes | SolidWorks Research Subsription | Solid modeling 计算机辅助设计 作者使用 |
| SuperGlue | Loctite | 234790 | 根据协议中的建议 |
| 测试浴 | 定制 | 作者使用 | |
| 薄膜握把 | 定制 | 作者使用 | |
| VeroWhitePlus | Stratasys Ltd | NA | 作者使用的 3D 打印材料 |
| WinTest | 作者用于收集数据的 | WinTest 软件 |