2023年10月6日
Here, we describe a straightforward protocol that enables in vitro assessment of the abundance of fluorescently labeled microRNAs to study the dynamics of microRNA packaging and export into extracellular vesicles (EVs).
My lab works on studying microRNAs and we have known for decades that microRNAs are depleted in cancer. However, the mechanism as to how these microRNAs are lost has not been actively understood. Our recent work on extracellular vesicles suggests that microRNAs that are depleted in cancer are being actively loaded into these extracellular vesicles.
Our goal now is to really get to the mechanism as to how these RNAs are actively loaded into these extracellular vesicles in the process of tumorigenesis. The protocol helps understand and capture the dynamic process of microRNA release into extracellular vesicles, which is one of the challenging areas in studying extracellular vesicle biology. Our findings provide a tool to advance the study of pathways that regulate depletion of microRNAs in cancer.
We plan on identifying functional and phenotypic consequences of the loss of specific subsets of microRNA via extracellular vesicles in cancer. Once we identify the factors that are involved in loading these microRNAs into extracellular vesicles, our goal is to downregulate these factors and evaluate the phenotypic consequence. Moreover, because we identified a motif that's contained in these small RNAs, we're curious to know whether this motif is both necessary and sufficient for loading these RNAs into the extracellular vesicles.
To begin, take Calu-6 cells transfected with fluorophore-conjugated EV-microRNA and cell-microRNA. Filter the cell suspension through a 35 micrometer strainer cap, included with the round bottom polystyrene FACS tubes. Then set up the flow cytometry instrument, switch on the flow cytometer and allow it to warm up for 30 minutes before use.
Prime the fluidics system with sheath fluid. After that, verify and adjust the laser alignment. For quality control, load ultrapure filtered water into the flow cytometer and run it at an appropriate flow rate, ensuring an adequate acquisition time.
Then set the threshold for capturing the signal from Calu-6 cells at FSC 5, 000. To account for spectral overlap between fluorophores, prepare compensation controls using untransfected cells and cells transfected with only fluorophore. Perform expression analysis in transfected cells using the FSC, SSC, FITC, and PE channels set at 258, 192, 269, and 423 voltage units respectively.
Then introduce the negative control sample into the flow cytometer. Capture cell signals after defining FSC and SSC intensities in a custom worksheet. Select FSC for the x-axis and SSC for the y-axis in the plot.
Draw a polygon around the population of interest to create a gate on the axis. To create a new plot using the gated population, set the x-axis to fluorescent signal one for cell-microRNA detection and the y-axis to fluorescence signal two for EV-microRNA detection. Establish compensation parameters for the individual fluorophores using cells independently transfected with each of the fluorescently-tagged microRNAs.
Flow cytometry analysis of cells transfected with cell-microRNA and EV-microRNA revealed a sequential decrease of fluorescent signal corresponding to EV-microRNA. In contrast, the signal corresponding to the cell-microRNA was retained in the cells, indicating that the fluorophore does not impact the retention of microRNAs by the cells. To begin, take EVs isolated from Calu-6 cells transfected with fluorophore-conjugated EV-microRNA and cell-microRNA.
Dilute the EVs in an appropriate volume of ultra filtered PBS to prepare the extracellular vesicle suspension for flow cytometry analysis. Use the nano flow cytometry to analyze nano-sized particles. Launch the software and configure the instrument according to the recommended calibration instructions.
Using performance nano beads, conduct the performance test. The instrument's performance is deemed optimal if the nano beads are detected within the standard size range. Determine the suitable flow rate for EV particle detection.
Now perform a quality control check using ultra pure filtered water to verify the instrument's fluidics and assess the performance of detectors and lasers. Configure the parameters to evaluate the sensitivity and resolution of different populations in the bead mix as per the manufacturer's protocol. Then apply appropriate gating to distinguish the bead population from instrument noise.
Next, thoroughly vortex the samples to ensure the even distribution EVs before loading them for analysis. Launch the flow cytometry data analysis software and introduce ultra filtered PBS. Using ultra filtered PBS, set up gating for EV particles, ensuring that the gating corresponds to the appropriate size of particles based on the calibration.
Take EVs that have been transferred and vortexed in an Attune compatible tube and load the tube into the instrument. Capture EV signals while plotting FSC on the x-axis and SSC on the y-axis. For cell-microRNA detection, on the x-axis, select fluorescent signal one, and for EV-microRNA detection on the y-axis, choose fluorescent signal two.
Using the EV samples isolated from cells transfected with a single microRNA, establish compensation parameters for the fluorophores. Flow cytometry revealed a time-dependent accumulation of miR-451a Alexa Fluor 488 in EVs supporting efficient packaging and release. In contrast, the fluorescence of cell-miR-67 was not observed in EVs.
查看完整文字稿并访问数千部科学视频
本研究旨在探讨在癌症背景下微小RNA(microRNA)被包装并分泌到细胞外囊泡(EVs)中的动态过程。通过采用一种简单的体外评估方案,作者试图阐明在癌症中通常减少的微小RNA如何被主动装载进入EVs,从而为肿瘤发生机制提供新的见解。
对miRNA向细胞外囊泡(EVs)中转运的定量追踪,填补了在疾病相关体系中理解细胞间通讯及miRNA耗竭机制的关键空白。本实验方案通过阐明miRNA装载进入EVs的动力学特征与特异性,可在靶点验证阶段实现机制层面的风险评估。此类研究结果有助于提升早期发现及转化研究流程的可预测性与可信度。
本方案通过实现对miRNA外排的定量分析,融入从发现到临床前研究的连续过程,支持假设验证和后续筛选。