An intraventricular balloon is a small, inflatable catheter device positioned within a brain ventricle to support neurosurgical diagnosis or treatment, particularly when cerebrospinal fluid flow is blocked. Under endoscopic or image-guided control, the balloon is advanced through a catheter and inflated to a defined size, allowing controlled dilation of an opening or temporary occlusion of a ventricular passage. In procedures such as endoscopic third ventriculostomy, balloon expansion can help create or enlarge a pathway for cerebrospinal fluid drainage and reduce pressure caused by hydrocephalus. Its use requires precise placement and monitoring to limit injury to surrounding neural tissue.

Intraventricular Balloon - Related Videos

Research

JoVE EoE - Neuropathology

Modeling Neonatal Intraventricular Hemorrhage Through Intraventricular Injection of Hemoglobin

0 Views •

2025

This video demonstrates a method to generate a rat model of neonatal intraventricular hemorrhage. In this procedure, an anesthetized rat pup is injected with hemoglobin into the lateral ventricle of the brain. The hemoglobin causes oxidative stress and releases heme, simulating intraventricular hemorrhage. The resulting damage to brain tissues, driven by reactive oxygen species and inflammatory cytokines, leads to ventricular enlargement, a common consequence of intraventricular hemorrhage.

Modeling Neonatal Intraventricular Hemorrhage Through Intraventricular Injection of Hemoglobin

0 Views •

Cited by 12 •

2022

We present a model of neonatal intraventricular hemorrhage using rat pups that mimics the pathology seen in humans.

Inducing Brain Death in a Mouse Model Using a Balloon Catheter

0 Views •

2025

This video demonstrates the procedure for inducing brain death in a mouse model by increasing controlled intracranial pressure through a balloon catheter, mimicking natural brain death.

In Utero Intraventricular Injection and Electroporation of E16 Rat Embryos

0 Views •

Cited by 13 •

2007

In-utero in-vivo injection and electroporation of the embryonic rat neocortex provides a powerful tool for the manipulation of individual progenitors ...

A Rat Carotid Balloon Injury Model to Test Anti-vascular Remodeling Therapeutics

0 Views •

Cited by 8 •

2016

The rat carotid balloon injury model described below allows researchers to evaluate drugs or therapeutics that negate injury-induced arterial hyperplasia. Detailed pre-surgical preparation, surgical procedure, and post-surgical cares of the animal are described.