-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

DE

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

German

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Biology
Dosimetrie für Zellbestrahlung mit Orthovoltage (40-300 kV) Röntgenanlagen
Dosimetrie für Zellbestrahlung mit Orthovoltage (40-300 kV) Röntgenanlagen
JoVE Journal
Biology
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
JoVE Journal Biology
Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities

Dosimetrie für Zellbestrahlung mit Orthovoltage (40-300 kV) Röntgenanlagen

Full Text
5,565 Views
06:51 min
February 20, 2021

DOI: 10.3791/61645-v

Morgane Dos Santos1, Vincent Paget2, François Trompier3, Gaëtan Gruel1, Fabien Milliat2

1Department of RAdiobiology and Regenerative MEDicine (SERAMED), Laboratory of Radiobiology of Accidental Exposures (LRAcc),Institute for Radiological Protection and Nuclear Safety (IRSN), 2Department of RAdiobiology and Regenerative MEDicine (SERAMED), Laboratory of MEDical Radiobialogy (LRMed),Institute for Radiological Protection and Nuclear Safety (IRSN), 3Department of DOSimetry (SDOS), Ionizing Radiation Dosimetry Laboratory (LDRI),Institute for Radiological Protection and Nuclear Safety (IRSN)

AI Banner

Please note that some of the translations on this page are AI generated. Click here for the English version.

Overview

This study presents a new dosimetry protocol for cell irradiations that closely simulates real cell irradiation conditions, allowing for precision in determining the dose received by cells. This protocol enhances the applicability of dosimetry across various x-ray facilities by integrating crucial parameters for accurate measurements.

Key Study Components

Research Area

  • Radiobiological studies
  • Dosimetry measurement
  • Cell irradiation techniques

Background

  • The need for precise dosimetry in biological research.
  • The limitations of existing protocols when applied to x-ray irradiation.
  • Importance of collaboration between physicists and radiobiologists.

Methods Used

  • Development and implementation of a self-developing dosimetry film protocol.
  • Calibration of films and dose rate measurements with ionization chambers.
  • Analytical measurements using ImageJ software for dose profiling.

Main Results

  • Accurate dose rates can be achieved by careful configuration of irradiation parameters.
  • Calibration curves generated for precise dose estimations.
  • Factors affecting dose measurements, such as medium attenuation, have been quantified.

Conclusions

  • This study demonstrates a reliable method for measuring radiation doses in cell cultures.
  • The findings have significant implications for advancing radiobiological research methodologies.

Frequently Asked Questions

What is dosimetry?
Dosimetry is the measurement and calculation of the radiation dose received by the human body or biological samples.
Why is accurate dosimetry important in biology?
Accurate dosimetry ensures that biological effects of radiation can be properly correlated with dose levels, which is crucial for experimentation and safety.
What equipment is used in this protocol?
The protocol utilizes low energy X-ray equipment, self-developing dosimetry films, and ionization chambers.
How does the new protocol differ from existing ones?
The new protocol simulates real cell irradiation conditions more accurately than prior methods, enhancing measurement reliability.
How is the calibration curve constructed?
A calibration curve is constructed using irradiated films at known dose points which are then fitted with a polynomial curve.
What role do physicists play in this protocol?
Physicists are crucial for setting irradiation parameters and ensuring accurate dosimetry measurements.
Can this protocol be applied to other cell types?
Yes, the protocol is versatile and can be adapted to different cell types depending on the experimental requirements.

Dieses Dokument beschreibt ein neues Dosimetrieprotokoll für Zellbestrahlungen mit Energie-Röntgengeräten. Die Messungen werden unter Bedingungen durchgeführt, die reale Zellbestrahlungsbedingungen so weit wie möglich simulieren.

Dieses Protokoll wurde entwickelt, um Dosimetriemessungen so nahe wie möglich an realen Zellbestrahlungsbedingungen für radiobiologische Studien durchführen zu können. Mit diesem Protokoll können wir die genaue Dosis bestimmen, die zellen erhalten, so dass sie für viele Röntgeneinrichtungen anwendbar ist, und alle Parameter berücksichtigen und in Dosimetrie übersetzen. Alle Bestrahlungsparameter müssen vorgelagert eingerichtet werden, um eine optimale Erfassung der Dosimetriemessung zu ermöglichen, die eine enge Zusammenarbeit zwischen Physikern und Radiobiologen erfordert.

Um eine Bestrahlungsfeldauswertung durchzuführen, legen Sie einen sich selbst entwickelnden Dosimetriefilm auf die unterstützungsmittelartige Bestrahlung und bestrahlen Sie den Film mit mindestens zwei Grautönen, um ein gut markiertes Bestrahlungsfeld zu erhalten. Scannen Sie den sich selbst entwickelnden Dosimetriefilm mit einem speziellen Scanner und verwenden Sie das Analyse- und Plotprofil, um das Dosisprofil in ImageJ zu zeichnen. Markieren Sie dann die Bestrahlungsunterstützungsfläche, um sicherzustellen, dass der Zellbehälter in die richtige Position gebracht wird.

View the full transcript and gain access to thousands of scientific videos

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

Biologie Ausgabe 168 Dosimetrie Niederenergie-Röntgenstrahlen Radiobiologie Bestrahlungsprotokoll Zellbestrahlung Röntgenanlage

Related Videos

Stem Cell Transplantation Strategien für die Wiederherstellung der kognitiven Dysfunktion von Cranial Strahlentherapie verursachten Schäden

11:24

Stem Cell Transplantation Strategien für die Wiederherstellung der kognitiven Dysfunktion von Cranial Strahlentherapie verursachten Schäden

Related Videos

15.2K Views

Charakterisierung der Rekombination Effekte in einer Flüssigkeit Ionisationskammer Wird für die Dosimetrie eines radiochirurgische Accelerator

07:31

Charakterisierung der Rekombination Effekte in einer Flüssigkeit Ionisationskammer Wird für die Dosimetrie eines radiochirurgische Accelerator

Related Videos

12.2K Views

Diffuse Optische Spektroskopie zur quantitativen Beurteilung Akute ionisierender Strahlung induzierte Hauttoxizität Mit einem Maus-Modell

06:21

Diffuse Optische Spektroskopie zur quantitativen Beurteilung Akute ionisierender Strahlung induzierte Hauttoxizität Mit einem Maus-Modell

Related Videos

8.6K Views

Beschleunigten Strahlung Biodosimetry automatisiert durch dizentrische Chromosom Identifikation (ADCI) und Abschätzung der Dosis

10:33

Beschleunigten Strahlung Biodosimetry automatisiert durch dizentrische Chromosom Identifikation (ADCI) und Abschätzung der Dosis

Related Videos

16.6K Views

One-Step-Protokoll für die Bewertung des strahleninduzierten klonogenen Zelltod durch Fluoreszenz-Mikroskopie-Modus

06:47

One-Step-Protokoll für die Bewertung des strahleninduzierten klonogenen Zelltod durch Fluoreszenz-Mikroskopie-Modus

Related Videos

11.9K Views

Einsatz eines Linearbeschleunigers zur Durchführung von In-Vitro-Radiobiologieexperimenten

06:08

Einsatz eines Linearbeschleunigers zur Durchführung von In-Vitro-Radiobiologieexperimenten

Related Videos

8K Views

Röntgenstrahl-Induzierte Strommessungen für die multimodale Röntgenmikroskopie von Solarzellen

10:16

Röntgenstrahl-Induzierte Strommessungen für die multimodale Röntgenmikroskopie von Solarzellen

Related Videos

14.4K Views

Bestrahlungsinbetriebnahme und Dosimetrie zur Bewertung von LQ-α und β Parametern, Strahlungsdosierungsschema und in-vivo-Dosisabscheidung

06:20

Bestrahlungsinbetriebnahme und Dosimetrie zur Bewertung von LQ-α und β Parametern, Strahlungsdosierungsschema und in-vivo-Dosisabscheidung

Related Videos

7.8K Views

Eine automatisierte mikroskopische Scoring-Methode für den γ-H2AX-Foci-Assay in humanen peripheren Blutlymphozyten

08:23

Eine automatisierte mikroskopische Scoring-Methode für den γ-H2AX-Foci-Assay in humanen peripheren Blutlymphozyten

Related Videos

5.4K Views

Nicht-invasive 3D-Visualisierung mit Sub-Mikron-Auflösung mit Synchrotron-Röntgen-Tomographie

08:51

Nicht-invasive 3D-Visualisierung mit Sub-Mikron-Auflösung mit Synchrotron-Röntgen-Tomographie

Related Videos

13.6K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code