Erratum: EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. II. Total Culturable Virus Assay

253 visualizaciones

⸱

DOI:

10.3791/5845

⸱

No publicado

En este artículo

Resumen

A correction was made to: EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. II. Total Culturable Virus Assay. The values for Reagent Grade Water shown in Figure 2 were changed from a mean value of 111% with a standard error of 8% to a mean value of 82% with a standard error of 26%.

Resumen

A correction was made to: EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. II. Total Culturable Virus Assay. The values for Reagent Grade Water shown in Figure 2 were changed from a mean value of 111% with a standard error of 8% to a mean value of 82% with a standard error of 26%.

The penultimate sentence of the last paragraph of the Representative Results section was changed from:

These controls performed similarly with a mean recovery of 111% and a coefficient of variation of 100% (Figure 2),

to:

These controls had a mean recovery of 82% and a coefficient of variation of 110% (Figure 2).

The third sentence of the fourth paragraph of the Discussion section was changed from:

The mean recovery from the LFB samples of 111% with a coefficient of variation (CV) of 100% also met the method performance acceptance criteria even though they are higher than that observed for PE samples during the ICR,

to:

The mean recovery from the LFB samples of 82% with a coefficient of variation (CV) of 110% also met the method performance acceptance criteria even though they are higher than that observed for PE samples during the ICR.

Protocolo

A correction was made to: EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. II. Total Culturable Virus Assay. The values for Reagent Grade Water shown in Figure 2 were changed from a mean value of 111% with a standard error of 8% to a mean value of 82% with a standard error of 26%.

The penultimate sentence of the last paragraph of the Representative Results section was changed from:

These controls performed similarly with a mean recovery of 111% and a coefficient of variation of 100% (Figure 2),

to:

These controls had a mean recovery of 82% and a coefficient of variation of 110% (Figure 2).

The third sentence of the fourth paragraph of the Discussion section was changed from:

The mean recovery from the LFB samples of 111% with a coefficient of variation (CV) of 100% also met the method performance acceptance criteria even though they are higher than that observed for PE samples during the ICR,

to:

The mean recovery from the LFB samples of 82% with a coefficient of variation (CV) of 110% also met the method performance acceptance criteria even though they are higher than that observed for PE samples during the ICR.

Divulgaciones

No conflicts of interest declared.

Reimpresiones y permisos

Etiquetas

Detección de enterovirusdetección de norovirusensayo de virus en aguaRT-qPCR de cultivoanálisis de recuperación de viruscoeficiente de variaciónagua de grado reactivocriterios de desempeño del método