Source: Bredow, M. et al., Pattern-Triggered Oxidative Burst and Seedling Growth Inhibition Assays in Arabidopsis thaliana. J. Vis. Exp. (147),(2019).

This video demonstrates the seedling growth inhibition assay in the Arabidopsis thaliana plant. The impact of increased concentration of immune peptide elicitor on seedling growth is determined.

Protocol

1. Seedling Growth Inhibition Assay

  1. Sterilize seeds and sow on Murashige and Skoog (MS) plates.
    1. Prepare sterile half-strength (0.5x) MS medium (2.16 g/L) containing 0.8% agar [w/v]. Pour media into plates (90 x 15 mm) in a laminar flow hood.
    2. Sterilize approximately 100 seeds in a microcentrifuge tube by washing with 1 mL of 70% ethanol for 2 min and remove by aspiration. Add 1 mL of 40% bleach and gently rock for 17 mins at room temperature. Remove bleach by aspiration and wash three times in 1 mL of sterile water for 5 min. Resuspend in 1 mL of sterile 0.1% agar.
      NOTE: Alternatively, use a c....

Access restricted. Please log in or start a trial to view this content.

Results

Seedling growth experiment with transplant method; petri dish to elf18 nM concentration assay plates.
Figure 1. Elicitor-induced seedling growth inhibition assay in Arabidopsis. (A) Sow seedlings on MS agar and grow for 3-4 days under standard short-day conditions. (B) Transplant seedlings to 48-well plates containing MS medium or MS containin.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
8-Well Sterile Plates with LidSigma-AldrichCLS3548
Analytical Scale with Draft SheidVWRVWR-225ACAny standard analytical scale can be used for growth inibition assays, however, a direct computer output is optimal.
BioHit mLine Mechanical 12 Multichannel Pipette (30-300 uLSartorius725240Any multichannel pipette can be used, as can a single pipetter if necessary.
elf18 (AcSKEKFERTKPHVNVGTIG)EZ Biolabcp7211Store 10 mM stock peptide at -80 deg C in low protein binding tubes. When thawed, store 100 uM working stock at -20 deg C.
Murisage and Skoog Basal SaltsCedarlane LabsMSP09-100LTStore at 4 deg C.