Flexible Probe Implantation

Flexible probe implantation is a neuroscience technique for placing soft, bendable electrode arrays or sensor devices within neural tissue to monitor or modulate brain activity. During implantation, the probe enters the target region and conforms more closely to tissue movement than rigid devices, helping establish stable interfaces for recording electrical signals or delivering stimulation. This approach supports studies of neural circuits, behavior, and neurological disease while enabling longer-term measurements in living organisms. Flexible probes also contribute to the development of brain-computer interfaces and other neurotechnologies designed to improve the compatibility, durability, and information quality of implanted neural devices.

Flexible Probe Implantation - Related Videos

Research

JoVE EoE - Neurotherapeutics

Implantation of a Flexible Biocompatible Probe in a Glioblastoma Mouse Model

0 Views •

2025

Source: Lefevre, M. C., et al., Flexible Organic Electronic Devices for Pulsed Electric Field Therapy of Glioblastoma. J. Vis. Exp. (2022)This video demonstrates the implantation of a flexible, biocompatible probe in a glioblastoma mouse model to deliver targeted pulsed electric field therapy for neurotherapeutic applications.

Insertion of Flexible Neural Probes Using Rigid Stiffeners Attached with Biodissolvable Adhesive

0 Views •

Cited by 99 •

2013

Insertion of flexible neural microelectrode probes is enabled by attaching probes to rigid stiffeners with polyethylene glycol (PEG). A unique assembly process ensures uniform and repeatable attachment. After insertion into tissue, the PEG dissolves and the stiffener is extracted. An in vitro test method evaluates the technique in agarose gel.

Positioning Laser Doppler Probe: A Technique to Implant Probe Over Middle Cerebral Artery for Blood Flow Measurement in Murine Model

0 Views •

2025

This video describes the surgical procedure to immobilize the laser Doppler probe over the murine brain's middle cerebral artery, or MCA. The probe helps to measure the blood flow in the brain's microvasculature by measuring the Doppler shift caused due to the motion of red blood cells within the artery.

Research

JoVE Journal - Neuroscience
Free Sample

Chronic Implantation of Multiple Flexible Polymer Electrode Arrays

0 Views •

Cited by 24 •

2019

Described below is a method for implantation of multiple polymer electrode arrays across anatomically distant brain regions for chronic electrophysiological recording in freely moving rats. Preparation and surgical implantation are described in detail, with emphasis on design principles to guide adaptation of these methods for use in other species.

Large-scale Recording of Neurons by Movable Silicon Probes in Behaving Rodents

0 Views •

Cited by 111 •

2012

We describe methods for large-scale recording of multiple single units and local field potential in behaving rodents with silicon probes. Drive fabrication, probe attachment to the drive and probe implantation processes are illustrated in sufficient details for easy replication.