Fluorescence Imaging Camera

A fluorescence imaging camera is an optical device that captures light emitted by fluorescent molecules after they absorb excitation light, enabling sensitive visualization of labeled structures and processes. In operation, excitation light illuminates a specimen or patient, while optical filters block the excitation wavelength and transmit fluorescence to a camera sensor, which converts the signal into a digital image. In medicine, fluorescence imaging cameras support the detection and mapping of tissues, cells, blood flow, and molecular markers during research, diagnosis, and image-guided procedures. Their ability to provide spatial and temporal information can improve visualization of biological features that are difficult to distinguish with conventional illumination.

Fluorescence Imaging Camera - Related Videos

Research

JoVE Journal - Immunology and Infection

Non-invasive In Vivo Fluorescence Optical Imaging of Inflammatory MMP Activity Using an Activatable Fluorescent Imaging Agent

0 Views •

Cited by 4 •

2017

This paper explains the application of fluorescent imaging using an activatable optical imaging probe to visualize the in vivo activity of key matrix metalloproteinases in two different experimental models of inflammation.

Research

JoVE Journal - Engineering
Free Sample

Determining 3D Flow Fields via Multi-camera Light Field Imaging

0 Views •

Cited by 7 •

2013

A technique for performing quantitative three-dimensional (3D) imaging for a range of fluid flows is presented. Using concepts from the area of Light Field Imaging, we reconstruct 3D volumes from arrays of images. Our 3D results span a broad range including velocity fields and multi-phase bubble size distributions.

Simultaneously Capturing Real-time Images in Two Emission Channels Using a Dual Camera Emission Splitting System: Applications to Cell Adhesion

0 Views •

Cited by 4 •

2013

Dual camera emission splitting systems for two-color fluorescence microscopy generate real-time image sequences with exceptional optical and temporal resolution, a requirement of certain live cell assays including parallel plate flow chamber adhesion assays. When software is employed to merge images from simultaneously acquired emission channels, pseudocolored image sequences are produced.

Wide-field Fluorescent Microscopy and Fluorescent Imaging Flow Cytometry on a Cell-phone

0 Views •

Cited by 32 •

2013

We review our recent results on the integration of fluorescent microscopy and imaging flow cytometry tools on a cell-phone using compact and cost-effective opto-fluidic attachments. These cell-phone based micro-analysis devices might be useful for cytometric analysis, such as performing various cell counting tasks as well as for high-throughput screening of e.g., water samples in resource limited settings.

Imaging and Quantification of the Area of Fast-Moving Microbubbles Using a High-Speed Camera and Image Analysis

0 Views •

Cited by 4 •

2020

Cavitation microbubbles are imaged using a high-speed camera attached to a zoom lens. The experimental setup is explained, and image analysis is used to calculate the area of the cavitation. Image analysis is done using ImageJ.

View All Results

FAQs

Related Topics