Visualization of Urinary Tract Infection in a Mouse Model Using Bioluminescence

0 views • 3:14 min • January 30th, 2026

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Begin with an anesthetized mouse and, using a catheter, inject a suspension of pathogenic bacteria into the urinary bladder.

These bacteria carry a bioluminescent operon, which enables autonomous light production to track the infection.

The bladder’s inner lining is a specialized epithelium that separates the lumen from the underlying tissue.

The bacterial adhesion proteins bind to the glycoprotein receptors on the host epithelial surface, triggering receptor-mediated endocytosis.

The internalized bacteria replicate to form dense intracellular bacterial communities.

The bacteria express the bioluminescent operon, producing a luciferase enzyme and an enzyme complex that synthesizes the luciferase substrate.

Luciferase oxidizes the substrate to emit visible light.

Position the mouse inside the imaging chamber and capture the bioluminescent signal.

Select a region of interest and quantify the bioluminescence intensity.

Monitor this signal over time as a real-time indicator of bacterial load and infection progression.

Open the BLI acquisition software and click on Initialize in the imaging device to test the camera and stage controller system and to cool the charge-coupled device camera to minus 90 degrees Celsius. Click on Acquisition, AutoSave To. Select Luminescence and Photograph. Check the default luminescent settings by setting the excitation filter to Block and emission filter to Open.

Set the exposure time to auto when taking the first image. For in vivo measurements and bright signals, set the exposure time to around 30 seconds. Reduce the exposure time if a warning appears due to a saturated image.

Select the medium binning, F/stop one, and choose the correct FOV. Set the subject height to 1 centimeter when imaging mice. Image up to 5 mice simultaneously and separate the animals using the light baffle to prevent reflection.

Close the door and click on Acquire to start the imaging sequence. Then fill in detailed information about the experiment. Remove mice from the imaging chamber and return them to their cage. Check for full recovery after anesthesia. Then return the cages to the ventilated racks until the next imaging cycle.

Start the imaging software and load the experimental file by clicking on Browse. Use the tool palette to adjust the color scale of the image. Use the ROI tools to draw a region of interest on the image, ensuring that it is large enough to cover the complete area and using the same dimensions for all the images. Then, click on ROI measurement to quantify the light intensity.

10:23

Urineweginfectie in een kleine diermodel: transuretrale catheterisatie van mannelijke en vrouwelijke muizen

Related Videos

0 Views

10:56

Dubbele bioluminescentie beeldvorming van tumor progressie en angiogenese

Related Videos

0 Views

07:19

Bioluminescente optogenetica 2.0: Bioluminescentie benutten om fotosensorische eiwitten in vitro en in vivo te activeren

Related Videos

0 Views

09:24

Transurethrale Inductie van Mouse urineweginfectie

Related Videos

0 Views

10:23

Met behulp van Luciferase naar Afbeelding bacteriële infecties in Muizen

Related Videos

0 Views

05:06

Bioluminescent Bacteriële Imaging In Vivo

Related Videos

0 Views

04:35

Tracking Bacterial Infection Dynamics in a Mouse Using Bioluminescence

Related Videos

0 Views

02:02

Bioluminescence Imaging of Bacterial Infections in Mice

Related Videos

0 Views

02:12

Real-Time Imaging of Bacterial Infection in a Mouse Model Using Bioluminescence

Related Videos

0 Views

02:06

Visualizing Intracellular Bacterial Communities in an Infected Mouse Bladder

Related Videos

0 Views

Last updated: 27 June 2026