Quantitative Flow Cytometry to Study Labeled Protein-Phospholipid Vesicle Interactions

0 weergaven2:43 min • July 8th, 2025

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Protein-phospholipid interactions on the cell membrane are crucial for the regulation of several cellular processes.

To detect target protein-phospholipid interactions in vitro using quantitative flow cytometry, take a tube containing a desired concentration of cell membrane mimic — micron-sized, lipophilic dye-labeled phospholipid vesicles — in buffer.

Add an appropriate concentration of different fluorescently-labeled target proteins in solution.

Inject the suspension into the flow cytometer. Set the fluidics system parameters to a low flow rate to allow sufficient time for the protein-phospholipid interactions.

As the fluorescently-labeled proteins and phospholipid vesicles interact in the flow channel, the concentration of proteins bound to the vesicles increases.

As these complexes pass through the laser beams from specific fluorescence channels providing appropriate wavelengths, they become excited. These excited proteins and phospholipid vesicles in the complex emit respective fluorescence signals upon relaxation to the ground state, which are captured by the appropriate detectors.

The detection of a high mean fluorescence intensity of the proteins is indicative of protein binding to the phospholipid vesicles.

Start the kinetic binding experiments by diluting phospholipid vesicles in Tyrode's buffer to a concentration of 1 micromolar and a total volume of 250 microliters. Then, mix fluorescent-labeled coagulation factor X or fX-fd at a concentration of 500 nanomolar with the phospholipid vesicles in a 1:1 ratio to get a total volume of 500 microliters.

Immediately inject 500 microliters of the mixed suspension into the flow cytometer at a flow rate with an excitation wavelength of 488 nanometers and an emission filter of 585 nanometers with a width of 42 for channel FL2.

Next, measure the mean fluorescence in channel FL4 with excitation at 633 nanometers and emission filter at 660 nanometers with a width of 20. When the saturation of binding is achieved, rapidly dilute the sample 20-fold with Tyrode's buffer, and monitor the dissociation until a baseline fluorescence or a plateau is reached.

11:22

Met behulp van 3 Single-molecuul FRET te bestuderen de correlatie van eiwitinteractie

Gerelateerde video's

0 Bekeken

11:10

Wasmiddel-vrije ultrasnelle reconstitutie van membraaneiwitten in lipide-Bilayers met behulp van Fusogenic aanvullende geladen Proteoliposomes.

Gerelateerde video's

0 Bekeken

09:12

Karakterisatie van menselijke monocyt deelverzamelingen door volbloed Stroom Cytometry analyse

Gerelateerde video's

0 Bekeken

07:33

Lipide bolletjes-gemedieerde affiniteitschromatografie met behulp van Magnetic Activated Cell Sorting (LIMACS): een nieuwe methode om eiwit-lipide Interactie Analyze

Gerelateerde video's

0 Bekeken

06:23

pH Modulation Assay on Supported Lipid Bilayers to Detect Protein-Phosphoinositide Interactions

Gerelateerde video's

0 Bekeken

11:11

Flowcytometrische analyse van Bimoleculaire Fluorescentie Complementatie: Een High Throughput kwantitatieve methode om eiwit-eiwit interactie Studie

Gerelateerde video's

0 Bekeken

09:39

Technieken voor de Analyse van de extracellulaire blaasjes Met behulp van flowcytometrie

Gerelateerde video's

0 Bekeken

10:52

Radioactief en kwantificering van cellulaire niveaus van fosfoinositiden door High Performance Liquid Chromatography-gekoppeld Flow Scintillation

Gerelateerde video's

0 Bekeken

10:58

PIP-on-a-chip: een labelvrije studie van eiwit-fosfoinositide-interacties

Gerelateerde video's

0 Bekeken

08:38

Phospho Stroom Cytometry met fluorescerende cel Barcoding voor eencellige signalering analyse en ontdekking van Biomarker

Gerelateerde video's

0 Bekeken

Laatst bijgewerkt: 15 augustus 2026