-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

PL

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

pl_PL

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Biology
Proste, ciągłe monitorowanie glikemii u swobodnie poruszających się myszy
Proste, ciągłe monitorowanie glikemii u swobodnie poruszających się myszy
JoVE Journal
Biology
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
JoVE Journal Biology
Simple Continuous Glucose Monitoring in Freely Moving Mice

Proste, ciągłe monitorowanie glikemii u swobodnie poruszających się myszy

Full Text
7,960 Views
03:25 min
February 24, 2023

DOI: 10.3791/64743-v

Doron Kleiman1, Mika Littor1,2, Mahmoud Nawas3, Rachel Ben-Haroush Schyr1, Danny Ben-Zvi1

1Department of Developmental Biology and Cancer Research, Institute of Medical Research Israel-Canada,The Hebrew University-Hadassah Medical School, 2Department of Military Medicine and “Tzameret”, Faculty of Medicine,Hebrew University of Jerusalem, and Medical Corps, Israel Defense Forces, 3Department of Surgery,Hadassah Medical Center-Ein Kerem Campus

AI Banner

Please note that some of the translations on this page are AI generated. Click here for the English version.

Overview

This study presents a straightforward method for implanting a commercial continuous glucose monitor (CGM) in mice to track glucose levels. The technique offers significant advantages, eliminating the need for complex microsurgery or bleeding, thus facilitating studies in obesity and diabetes models.

Key Study Components

Research Area

  • Diabetes research
  • Metabolic phenotype identification
  • Glucose monitoring in animal models

Background

  • Importance of monitoring glucose levels in obesity and diabetes research
  • Challenges associated with traditional surgical approaches
  • Need for effective methods to explore glucose management phenotypes

Methods Used

  • The procedure for inserting a CGM cannula
  • Mice as the biological model system
  • Utilization of suture techniques and sensor activation

Main Results

  • The method successfully secured the CGM cannula for extended monitoring
  • Data collected revealed new insights into metabolic phenotypes
  • Demonstrated feasibility and efficiency in data acquisition from mice

Conclusions

  • The study illustrates a reliable protocol for glucose monitoring in mice
  • This method contributes to advancing research in metabolic disorders

Frequently Asked Questions

What is the main advantage of this glucose monitoring method?
It simplifies the monitoring process and eliminates the need for invasive surgery or bleeding, making it less stressful for the mice.
How long can the CGM monitor glucose levels?
The method allows for continuous data collection, with effective monitoring over multiple days, as demonstrated in a three-day data collection period.
What biological models can benefit from this technique?
The technique is particularly useful in mouse models of obesity and diabetes, aiding in the identification of glucose management phenotypes.
What preparations are necessary before implanting the CGM?
It involves shaving the midline of the mouse's back, using depilatory cream, and making a small incision for cannula placement.
Are there any specific challenges when implementing this method?
The critical step is the careful insertion of the cannula and securing it properly to ensure it remains in place during the monitoring period.
Can the data collection parameters be adjusted?
Yes, the scripts provided allow modulation of various parameters during data analysis.
What type of data does this method produce?
The method produces continuous glucose monitoring data, which can reveal metabolic insights in mouse models.

Tutaj opisujemy prostą metodę wszczepienia myszom komercyjnego ciągłego monitora glikemii przeznaczonego dla pacjentów i dostarczamy skrypty do analizy wyników.

Nasz protokół oferuje prostą, niedrogą metodę monitorowania poziomu glukozy u myszy. Główną zaletą tej techniki jest to, że nie wymaga wymagającej mikrochirurgii i nie wiąże się z krwawieniem ani obchodzeniem się z myszami. Metoda ta może być wykorzystana do identyfikacji nieuchwytnych fenotypów zarządzania glukozą w mysich modelach otyłości i cukrzycy.

Podczas prób tego protokołu najbardziej krytycznym krokiem jest wprowadzenie kaniuli pod skórę i zaciśnięcie szwów wewnętrznych w celu utrzymania kaniuli na miejscu. Aby rozpocząć, ogol linię środkową grzbietu znieczulonej myszy i użyj kremu do depilacji, aby zapewnić całkowite usunięcie włosów. Otwórz i załaduj czujnik.

View the full transcript and gain access to thousands of scientific videos

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

Ciągłe monitorowanie glikemii poziom glukozy monitorowanie myszy wprowadzanie kaniuli modele otyłości badania nad cukrzycą kieszonka podskórna aktywacja czujnika technika szycia surowe dane wyjściowe fenotypy zarządzania glukozą niedroga metoda gromadzenie danych badania biomedyczne

Related Videos

Klamry hiperinsulinemiczno-euglikemiczne u przytomnych, nieskrępowanych myszy

11:10

Klamry hiperinsulinemiczno-euglikemiczne u przytomnych, nieskrępowanych myszy

Related Videos

95.9K Views

Testy do jakościowej i ilościowej oceny stężeń glukozy w moczu myszy

04:42

Testy do jakościowej i ilościowej oceny stężeń glukozy w moczu myszy

Related Videos

1.2K Views

Ocena wpływu ciągłego wlewu leku do mózgu myszy na obwodowy poziom glukozy

02:21

Ocena wpływu ciągłego wlewu leku do mózgu myszy na obwodowy poziom glukozy

Related Videos

517 Views

Długoterminowy pomiar ciśnienia krwi u swobodnie poruszających się myszy za pomocą telemetrii

07:54

Długoterminowy pomiar ciśnienia krwi u swobodnie poruszających się myszy za pomocą telemetrii

Related Videos

21.9K Views

Badanie sygnału insuliny podwzgórzowej do obwodowej nietolerancji glukozy za pomocą systemu ciągłego wlewu leków do mózgu myszy

08:32

Badanie sygnału insuliny podwzgórzowej do obwodowej nietolerancji glukozy za pomocą systemu ciągłego wlewu leków do mózgu myszy

Related Videos

10.9K Views

Badanie metabolizmu glukozy in vivo u myszy karmionych dietą wysokotłuszczową przy użyciu doustnego testu tolerancji glukozy (OGTT) i testu tolerancji insuliny (ITT)

08:13

Badanie metabolizmu glukozy in vivo u myszy karmionych dietą wysokotłuszczową przy użyciu doustnego testu tolerancji glukozy (OGTT) i testu tolerancji insuliny (ITT)

Related Videos

71.8K Views

Ocena produkcji glukozy w wątrobie w mysim modelu zespołu policystycznych jajników

09:44

Ocena produkcji glukozy w wątrobie w mysim modelu zespołu policystycznych jajników

Related Videos

3.4K Views

Implantacja minipompy osmotycznej w celu zwiększenia stężenia glukozy w płynie mózgowo-rdzeniowym myszy

06:21

Implantacja minipompy osmotycznej w celu zwiększenia stężenia glukozy w płynie mózgowo-rdzeniowym myszy

Related Videos

2.1K Views

Zacisk hiperglikemiczny i zacisk hipoglikemiczny u świadomych myszy

07:35

Zacisk hiperglikemiczny i zacisk hipoglikemiczny u świadomych myszy

Related Videos

2.2K Views

Analiza komunikacji neuronalnej jelitowo-mózgowej w czasie rzeczywistym: dynamika wapnia w całej korze mózgowej w odpowiedzi na stymulację glukozy w jelitach

07:29

Analiza komunikacji neuronalnej jelitowo-mózgowej w czasie rzeczywistym: dynamika wapnia w całej korze mózgowej w odpowiedzi na stymulację glukozy w jelitach

Related Videos

1.1K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code