Source: Chang, X., et al. Preparation of Pseudo-Typed H5 Avian Influenza Viruses with Calcium Phosphate Transfection Method and Measurement of Antibody Neutralizing Activity. J. Vis. Exp. (2021)

This video demonstrates a luciferase-based pseudovirus titration assay to determine the optimal target cell density for maximum infection. By comparing luminescence across cell densities, the method ensures high assay sensitivity and reproducibility for downstream applications.

Protocolo

1. Pseudovirus titration

  1. Make single-cell suspensions of Madin-Darby canine kidney (MDCK) cells (5 x 104 per mL) in complete Dulbecco's modified Eagle medium (DMEM medium), and add 1250, 2500, 5000, 10000, 20000, and 40000 cells to different wells of a 96-well flat-bottom plate. Incubate the cells in a 37 °C, 5% CO2 incubator for 20 h.
  2. Take out the pseudovirus from the -80 °C refrigerator, thaw it on the ice, and vortex the pseudovirus.
  3. Add 6 HAU (6x Hemagglutinating units) pseudoviruses to each well of the 96-well round-bottom plate and replenish each well with complete DMEM up to 120 µL.
  4. Pipett....

Acesso restrito. Inicie sessão ou comece um teste para visualizar este conteúdo.

Materiais

Lista de materiais utilizados neste artigo
NomeEmpresaNúmero de catálogoComentários
96-well cell culture plates (flat-bottom)Thermo fisher scientific167008Consumable material
96-well cell culture plates (round-bottom)Thermo fisher scientific163320Consumable material
Allegra X-15RBeckman coulter--Equipment/Centrifuge
Dulbecco’s Modified Eagle Medium (DMEM)Gibco12100-046Reagent
Luciferase Assay System Freezer PackPromegaE4530Reagent kit
MDCK.1ATCCCRL-2935Cell line
Microcentrifuge Tubes 1.5 mLThermo fisher scientific509-GRD-QConsumable material
Pipette Tips (10 μL)Thermo fisher scientificTF102-10-QConsumable material
Pipette Tips (100 μL)Thermo fisher scientificTF113-100-QConsumable material
Pipette Tips (1000 μL)Thermo fisher scientificTF112-1000-QConsumable material