-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Lab Manual
Chemistry
Lab Techniques
Video Quiz
Lab Techniques
Lab Manual
Chemistry
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
Lab Manual Chemistry
Lab Techniques

Lab Techniques

Skip to

Concept

Instructor Prep

Student Protocol

282,289 Views
04:14 min
March 26, 2020

Measurement Accuracy

The ability to repeat an experiment and get the same results, or reproducibility, is essential in scientific research. However, it’s impossible to repeat an experiment if you don’t know how you did it. Thus, scientists keep detailed records of their experiments in lab notebooks. These records include important information like the amount of each material used and descriptions of each step of the procedure.

Equipment, like balances and volumetric or graduated glassware, is used to measure solid and liquid compounds for experiments. The precision of each measurement is limited by the equipment used. Balances and other equipment with digital readouts automatically display values at the maximum precision that they can support. The precision of graduated glassware and rulers depends on the increment, which is the amount represented by the smallest distance between two marks.

The surface of most liquids curves upwards at the edges in glass containers. This type of curved liquid surface is called a concave meniscus. When the edges of the liquid curve down, it is called a convex meniscus. When measuring liquid volumes, the reference point for the top of the liquid is the bottom of a concave meniscus or the top of a convex meniscus. To accurately identify the position of the meniscus, liquid volumes are read by looking at the liquid’s surface from the side at eye-level. Looking at the liquid from above or below will cause the liquid surface level to appear higher or lower than it actually is.

When the reference point of the meniscus touches a mark on graduated or volumetric glassware, the glassware is holding the volume defined for that mark. Volumetric glassware is designed to measure a specific volume, so it only has one mark. Graduated glassware is designed to measure a range of volumes, so it has many marks, or graduations, which are labeled at regular intervals. Both graduated and volumetric glassware may have additional manufacturer-provided information about their precision.

Calibration and Uncertainty

Manufacturers calibrate equipment to ensure that the measurements are accurate to within a specified range of uncertainty. For example, a high-precision analytical balance may read out to four decimal places (0.0000 g) with an uncertainty of ± 0.0001 g. A reading of 0.0345 g indicates that the true value is between 0.0344 g and 0.0346 g.

Glassware typically has its measurement uncertainty printed on it. To accurately record volume measurements, you must consider both the increment and the uncertainty. For example, a precise volume measurement in a 100 mL graduated cylinder with 1 mL increments and an uncertainty of ± 0.5 mL would be recorded to the tenths place (000.0 mL ± 0.5 mL). If the reference point of the meniscus falls between two marks, you should estimate a value for the tenths place; otherwise, leave it as 0. Since temperature affects volume, the temperature for which the glassware is calibrated will be printed on it.

Glassware is calibrated either to contain (TC) or to deliver (TD). TC glassware holds the specified volume of liquid when it is filled to the mark, but a small amount of liquid will be left behind when it is poured into another container. Solutions are often prepared in TC glassware because the accuracy of the solution volume affects the accuracy of the concentration. Volumetric flasks are typically calibrated to contain.

TD glassware holds a little more than the amount of liquid specified when it is filled to the mark, but it dispenses only the specified volume. Thus, TD glassware should not be emptied completely when dispensing liquids. This type of glassware is useful for transferring a precise volume of liquid to another container. Both graduated and volumetric pipettes are typically calibrated to deliver.

Unless otherwise specified, the uncertainty of a number is assumed to be on the scale of the last digit. Thus, it’s particularly important to report the uncertainty of a measurement if the uncertainty is on a larger scale. For rulers and graduated glassware without a known uncertainty, the uncertainty is estimated as half of the smallest increment. The uncertain digit is based on where the meniscus falls between two tick marks.

Significant Figures

Significant figures are the numbers in a value that are meaningful, or essential for expressing that value with the appropriate precision. All numbers other than leading zeroes (0.001), trailing zeroes (1,000), or scientific notation multipliers (10x) are always significant.

Leading zeroes are never significant because they can be removed by rewriting the number either in scientific notation or, if it is an SI unit, in smaller units. For example, there are only three significant figures in the value 0.00123 m because it can be rewritten as either 1.23 × 10-3 m or 1.23 mm without losing any information. Note that the scaling factor between different multiples of the same SI unit does not affect the number of significant figures.

Trailing zeroes are significant when they are before or after a decimal point. For example, the measurement 100.110 mL has six significant figures and 100.0 mL has four. Trailing zeroes in a number written without a decimal point are assumed to be insignificant unless they are marked otherwise. There are several different conventions for marking significant zeroes in those cases, but to avoid ambiguity it is advisable to rewrite those values in scientific notation. If the measurement is in SI units, use larger units.

The precision of a measurement limits the precision of any values calculated from it. A calculated value has the same number of significant figures as the least precise measurement or value used in its calculation. If the result has too many significant figures, it is rounded to the appropriate precision. If the result has too few significant figures, it is extended with significant trailing zeroes to preserve the precision. The significant figures of experimentally derived values, like molar mass, density, or some unit conversion factors, must also be considered when they are used in calculations.

The number of significant figures in a calculated value is not limited by physical or mathematical constants in formulas or exact numbers, like the number of data points acquired in an experiment. For example, the formula for calculating the volume of a sphere is V = 4/3πr3. The number of significant figures in the calculated volume is only affected by the number of significant figures in the radius measurement r. 4/3  and π are constants, and 3 is simply notation for a mathematical operation.

Defined conversion factors are also treated as constants. For instance, the inch is defined as exactly 25.4 millimeters; therefore, the number of significant figures of the converted value depends only on the original measurement. Always check whether the conversion factor is exactly defined or an experimental value when converting between units.

For simple addition and subtraction of measurements, we use significance arithmetic to determine the number of significant figures. In this case, the answer has as many decimal places as the measurement with the fewest decimal places regardless of the number of significant figures. Thus, 15,643.7 mL + 0.613 mL = 15,644.3 mL.

For multi-step calculations or complex equations that you break into smaller parts to solve, you should keep at least one or two insignificant figures on the intermediate values. For example, if you calculate the values of the numerator and denominator of a fraction separately before dividing them, you should retain the insignificant figures of the numerator and denominator when you divide them. This minimizes rounding error, which is the difference from the number you would get if you entered the entire formula into your calculator at once. If you write down these intermediate values, you should note which digits are insignificant.

References

Harris, D.C. (2015). Quantitative Chemical Analysis. New York, NY: W.H. Freeman and Company.

Transcript

In scientific research, the reproducibility of an experiment is extremely important. Thus, keeping a lab notebook with detailed procedural recordings along with proper lab techniques helps reproduce experimental findings.

For example, simple measurements, like liquid volume, must be performed using the proper glassware to ensure accuracy. Always measure volume using volumetric glassware, like a volumetric flask, graduated cylinder, or volumetric pipette. The volume is measured at the bottom of the meniscus.

Volume markings on beakers and Erlenmeyer flasks are not accurate and serve as guidelines only. When selecting the volumetric glassware, select the smallest container possible for the volume needed. Volumetric glassware is calibrated either to deliver or to contain.

Containers calibrated to deliver are designed to provide the volume stated with the understanding that a small amount of liquid will remain in the glassware after it is emptied. In this case, there is no need to remove the remaining liquid or more than the desired volume will be emptied. Glassware calibrated to contain will hold and deliver the volume stated but require that the remaining liquid will be poured out so that the full volume is received.

We measure to obtain a true value. However, there will always be some level of uncertainty and error. The measured value is our best estimate of the actual value, which is often unknown to us. Error is the difference between the measured and actual values. Measurement uncertainty describes the range in which we think it is likely that the actual value lies. When recording measurements, it is important to maintain the appropriate number of significant figures.

Significant figures are the digits in a measurement that carry meaning. The last digit recorded defines the level of uncertainty. All numbers other than leading and trailing zeros are significant. And trailing zeros are significant when there is a decimal point preceding them.

For example, in a measurement of length using a ruler, we see that the length is at least one inch, but certainly not 2 inches. So, the first significant digit is one. The next tick mark represents 0.1 inches and is also significant.

A recording of 1.1 inches has two significant digits and implies that the uncertainty lies in the tenths place. However, the true width lies between two tick marks. So, the uncertainty lies here in the hundredths place as the length is reported as 1.15 inches.

When conducting calculations using measured values, remember not to carry out calculations to a higher resolution than the original measurement. Those additional digits are not significant and should not be included. For example, when calculating the area of the square with a side length of 1.15, we see that the length has three significant figures. So, the answer should also have three significant figures.

The calculated area of 1.3225 inches squared has five figures and introduces certainty into the calculation that was not there in the original measurement. Thus, the correct area is 1.32 inches squared.

In this lab, you'll practice proper lab skills by measuring the density of an egg and utilizing significant figures in your calculations and recordings. In addition, you will practice record keeping in your lab notebook and examine the accuracy of measurements with volumetric glassware.

Explore More Videos

JoVE Lab ChemLab: 33 Concept

Skip to

Concept

Instructor Prep

Student Protocol

Related Videos

Scientific Measurement and Lab Skills

04:34

Scientific Measurement and Lab Skills

Chemistry

172.4K Views

Stoichiometry, Product Yield, and Limiting Reactants

03:40

Stoichiometry, Product Yield, and Limiting Reactants

Chemistry

98.9K Views

Redox Reactions

04:56

Redox Reactions

Chemistry

148.5K Views

Ideal Gas Law

04:06

Ideal Gas Law

Chemistry

147.9K Views

Acid and Base Concentrations

06:35

Acid and Base Concentrations

Chemistry

125.2K Views

Buffers

04:35

Buffers

Chemistry

160.5K Views

Enthalpy of Reaction

03:37

Enthalpy of Reaction

Chemistry

140.6K Views

Solubility

04:02

Solubility

Chemistry

93.7K Views

Metal Flame Emission

02:47

Metal Flame Emission

Chemistry

83.7K Views

Balmer Series

03:53

Balmer Series

Chemistry

80.8K Views

Beer's Law

02:53

Beer's Law

Chemistry

110.8K Views

Concentration Dependence

04:37

Concentration Dependence

Chemistry

31.4K Views

Temperature Dependence

03:17

Temperature Dependence

Chemistry

33.6K Views

Galvanic Cells

03:31

Galvanic Cells

Chemistry

83.4K Views

Electrolytic Cells

02:52

Electrolytic Cells

Chemistry

47.9K Views

Proper Lab Notebook Keeping

03:06

Proper Lab Notebook Keeping

Chemistry

162.9K Views

Basic Organic Chemistry Techniques

03:08

Basic Organic Chemistry Techniques

Chemistry

85.7K Views

Melting Points

05:12

Melting Points

Chemistry

181.2K Views

Boiling Points

04:25

Boiling Points

Chemistry

61.1K Views

Recrystallization

03:12

Recrystallization

Chemistry

185.7K Views

Extraction

02:55

Extraction

Chemistry

360.5K Views

Simple Distillation

03:13

Simple Distillation

Chemistry

172.3K Views

Steam Distillation

03:54

Steam Distillation

Chemistry

107.0K Views

Thin-Layer Chromatography

03:07

Thin-Layer Chromatography

Chemistry

357.0K Views

Column Chromatography

03:07

Column Chromatography

Chemistry

147.4K Views

Hydrolysis of an Ester

04:10

Hydrolysis of an Ester

Chemistry

78.4K Views

Synthesis of Luminol

03:02

Synthesis of Luminol

Chemistry

18.7K Views

Esterification

03:48

Esterification

Chemistry

133.2K Views

Identification of Unknown Aldehydes and Ketones

03:09

Identification of Unknown Aldehydes and Ketones

Chemistry

270.0K Views

UV-Vis Spectroscopy of Dyes

04:55

UV-Vis Spectroscopy of Dyes

Chemistry

153.8K Views

Identifying Alcohols

03:32

Identifying Alcohols

Chemistry

163.8K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code