A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

An Assay for Bacterial Extracellular Protein-Mediated Cytotoxicity on PMNs

821 views

⸱

July 8th, 2025

In This Article

Abstract

Source: Dankoff, J. G., et al. Quantifying the Cytotoxicity of Staphylococcus aureus Against Human Polymorphonuclear Leukocytes. J. Vis. Exp. (2020).

This video demonstrates an assay to investigate the cytotoxicity of proteins produced by Staphylococcus aureus, a pathogenic bacterium, on isolated human polymorphonuclear leukocytes (PMNs). The secreted cytotoxic proteins form pores on the PMN cell membrane, initiating cell death. Upon staining the dead cells using propidium iodide, flow cytometry is performed to quantify the dead cells and assess the cytotoxicity of the bacteria.

Protocol

All procedures involving human participants have been performed in compliance with the institutional, national, and international guidelines for human welfare and have been reviewed by the local institutional review board.

1. Purification of human polymorphonuclear leukocytes and isolation of human serum

NOTE: All reagents should be routinely checked for the presence of endotoxin using a commercially available endotoxin detection kit and should contain <25.0 pg/mL endotoxin to prevent unwanted priming of PMNs.

  1. Bring 50 mL of 3% dextran-0.9% NaCl (w/v), 35 mL of 0.....

Access restricted. Please log in or start a trial to view this content.

Results

Flow cytometry dot plots and histogram; cell viability analysis; forward scatter vs. side scatter.
Figure 1: Flow cytometry analysis of purified PMNs. Representative flow cytometry dot plots of (A) purified human PMNs and (B) PMNs that have been purposely contaminated with peripheral blood mononuclear cells. (C) Representative flow cytometry histogram .......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
0.9% Sodium Chloride Injection, USP, 500 mL VIAFLEX Plastic ContainerBaxter2B1323QPMN purification
1.5 mL micro-centrifuge tubes with Snap CapsVWR89000-044Used in washing cells
1.8% Sodium Chloride SolutionSigma-AldrichS5150PMN purification
12x75mm Culture tubesVWR60818-430Used as flow cytometry tubes
20% (w/w) DextranSigma-AldrichD8802PMN purification
3125 Hand Tally CounterTraceable Products3125CCFor counting cells
50 mL conical centrifuge tubesVWR89039-656For dispensing media
Bacto Tryptic Soy Broth, Soybean-Casein Digest MediumFischerScientific211823For growing cell cultures
BD Disposable Syringes with Luer-Lok Tips, 3 mLFischerScientificBD 309657For filtering supernatants
Bright-Line HemocytometerSigma-AldrichZ359629Cell counting apparatus
DPBS, 1x (Dulbecco's Phosphate Buffered Saline) with calcium and magnesiumCorning21-030-CVUsed in washing cells
Ficoll-Paque PLUSGE Healthcare17-1440-02PMN purification
Fisherbrand Sterile Polystyrene Disposable Serological PipetsFischerScientific13-678-11EFor aspirating liquid
Greiner CELLSTAR 96 well platesMillipore SigmaM0687Plate for holding experimental samples
OMICRON Syringe FiltersOmicron ScientificSFPV13RFor filtering supernatants
Propidium iodideThermoFisher ScientificP3566Membrane impermeable DNA stain
PYREX Brand 4980 Erlenmeyer FlasksCole-ParmerEW-34503-24For growing cell cultures
RPMI 1640, 1X without L-glutamine, phenol redCorning17-105-CVUsed in resuspending cells
Sterile Water for Irrigation, USPBaxter2F7113PMN purification
The Pipette PumpBel-Art ProductsF37898For aspirating liquid
Triton X-100Sigma-AldrichX100Membrane integrity positive control

Explore More Articles

Staphylococcus aureusPolymorphonuclear LeukocytesLeukocidin CytotoxicityFlow CytometryPropidium IodidePore FormationNLRP3 InflammasomeSupernatant FiltrationSerial DilutionCytotoxicity Assay